One to Six Gas Portable Monitor with PID – Eagle 2

Features:

  • Monitor up to 6 different autoranging gases
  • PPM / LEL hydrocarbon detection
  • PID (photo ionization detector) low and high range for VOC detection
  • Infrared sensors available for CO2, % LEL CH4,
  • % Vol. CH4, % LEL HC, % Vol. HC
  • TC (thermal conductivity) sensor available for % Vol. H2 or % Vol. CH4
  • Plug and play, smart toxic sensors
  • Hundreds of configurations
  • Displays in 5 languages
  • Powerful long-life pump up to 38m range
  • Low flow pump shut off and alarm
  • Methane elimination for environmental use
  • Alkaline 16 hours or Ni-MH 20 hours capability
  • Password protection
  • Data logging standard
  • IrDA communications port
  • Autocalibration
  • Internal hydrophobic dust filter
  • External probe with hydrophobic filter
  • Ergonomic RFI / EMI / chemical / weather resistant enclosure
  • Intrinsically safe design, CSA approval

Application/s:

  • Portable Monitoring
  • Oxygen Monitoring

The Eagle 2 one to six gas portable monitor with PID is the newest member of the Control Equipment family.  Equipped with features that are not available on competitive units, the Eagle 2 one to six gas portable monitor with PID is a powerful instrument that does more than just offer the standard confined space protection.  One of the new features of the Eagle 2 is a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases.

The Eagle 2 includes a PID sensor for detecting high and low ppm levels (0-50 & 0-4,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; methane elimination feature for environmental applications; and a variety of super toxic gases and measurable ranges.

The Eagle 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 38 meters. This allows for quick response and recovery from distant sampling locations. The Eagle 2 will continuously operate for over 16 hours on alkaline batteries or 20 hours on Ni-MH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, to name a few. Data logging is a standard feature for all sensors on all versions. With its ergonomic design and large glove friendly buttons, the Eagle 2 offers easy access to controls such as auto calibration, alarm silence, demand zero, peak hold, methane elimination, and a wide variety of other features.

Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the Eagle 2 is the solution for just about any portable gas monitoring situation.

Specifications:

Enclosure Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP64.
Dimensions 9.5” L x 5.25” W x 5.875” H
Weight 3.8 Lbs (standard 4 gas with batteries).
Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, Photoionization detector, and thermal conductivity.
Sampling Method Powerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.
Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand, with adjustable time.
Language Readout can display in 5 languages (English, French, German, Italian, or Spanish).
Alarms 2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable.
Alarm Method Buzzer 95 dB at 30 cm, four high intensity LED’s.
Controls 4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features.
Continuous Operation At 70°F, 18 hours using alkaline batteries, or 20 hours using NiMH.
Power Source 4 alkaline or NiMH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines).
Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing.
Environmental IP-64
Response Time 30 Seconds to 90% (for most gases) using standard 5 ft hose.
Safety Rating Intrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA / CE
Standard Accessories Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter.
Optional Accessories • Dilution fitting (50/50) • NiMH batteries • Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours) • Continuous operation adapter, 115 VAC or 12 VDC • Extension hoses • IRDA cable for datalogging download
Warranty Two year material and workmanship, one year for PID sensor.

Downloads:

Specifications

Eagle 2 Introduction

Eagle 2 Operation

Eagle 2 Description

Eagle 2 Calibration Mode

Eagle 2 Maintenance

Eagle 2 PID Sensor

Eagle 2 Set Up Mode

Accessories:

Calibration Station SDM-E2

Overview

The Eagle 2 one to six gas portable monitor with PID is the newest member of the Control Equipment family.  Equipped with features that are not available on competitive units, the Eagle 2 one to six gas portable monitor with PID is a powerful instrument that does more than just offer the standard confined space protection.  One of the new features of the Eagle 2 is a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases.

The Eagle 2 includes a PID sensor for detecting high and low ppm levels (0-50 & 0-4,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; methane elimination feature for environmental applications; and a variety of super toxic gases and measurable ranges.

The Eagle 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 38 meters. This allows for quick response and recovery from distant sampling locations. The Eagle 2 will continuously operate for over 16 hours on alkaline batteries or 20 hours on Ni-MH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, to name a few. Data logging is a standard feature for all sensors on all versions. With its ergonomic design and large glove friendly buttons, the Eagle 2 offers easy access to controls such as auto calibration, alarm silence, demand zero, peak hold, methane elimination, and a wide variety of other features.

Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the Eagle 2 is the solution for just about any portable gas monitoring situation.

Specifications

Specifications:

Enclosure Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP64.
Dimensions 9.5” L x 5.25” W x 5.875” H
Weight 3.8 Lbs (standard 4 gas with batteries).
Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, Photoionization detector, and thermal conductivity.
Sampling Method Powerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.
Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand, with adjustable time.
Language Readout can display in 5 languages (English, French, German, Italian, or Spanish).
Alarms 2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable.
Alarm Method Buzzer 95 dB at 30 cm, four high intensity LED’s.
Controls 4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features.
Continuous Operation At 70°F, 18 hours using alkaline batteries, or 20 hours using NiMH.
Power Source 4 alkaline or NiMH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines).
Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing.
Environmental IP-64
Response Time 30 Seconds to 90% (for most gases) using standard 5 ft hose.
Safety Rating Intrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA / CE
Standard Accessories Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter.
Optional Accessories • Dilution fitting (50/50) • NiMH batteries • Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours) • Continuous operation adapter, 115 VAC or 12 VDC • Extension hoses • IRDA cable for datalogging download
Warranty Two year material and workmanship, one year for PID sensor.
Downloads

Downloads:

Specifications

Videos

Eagle 2 Introduction

Eagle 2 Operation

Eagle 2 Description

Eagle 2 Calibration Mode

Eagle 2 Maintenance

Eagle 2 PID Sensor

Eagle 2 Set Up Mode

Accessories

Accessories:

Calibration Station SDM-E2

Enquire Now

    Name*

    Phone*

    Location

    Email*

    Message