Features:
• 3 Year Warranty
• Personal monitoring for O2, H2S, CO
(Toxic – HCN, NO2, SO2, PH3, NH3 & CL2)
• CO with H2 elimination
• O2 / CO combo sensor
• Operates 3,000 hours on alkaline
• Pocket size 53mm (W) x 66mm (H) x 22mm (D)
• Lightweight approx 93 grams
• Impact, dust, and water resistant (IP-67)
• Replaceable rubber boot
• Data log 5 to 300 hours with adjustable intervals
• Audible / visual / vibration alarms
• Automatic backlight
• Low battery alarm
• Intrinsically safe, IECEx/ATEX
Application/s:
• Hazardous material
• Mining
• Refineries / petrochemical
• Water / wastewater treatment
• Pharmaceuticals
• Utilities
• Chemical plants
• Fire services
Overview:
The 04 Series Single Gas Detector is designed to operate for many years because they have 2 preset alarms that are user adjustable.
Meanwhile, each version is also equipped with visual, audible, and vibration alarms as per the standard.
These sensors also have a life expectancy of over 3 years. In addition, they’re backed by a 3-year warranty.
Furthermore, every 04 Series single gas detector is impact, dust, and water resistant with an IP-67 rating. As a result, these instruments are safe for use in hazardous locations, classified as intrinsically safe IECEx/ATEX.
Specifications:
Model Name | SC-04 HCN | SC-04 NO2 | SC-04 PH3 | SC-04 SO2 | CO-04 (-H2) | CX-04 | |
Gas Detected | Hydrogen Cyanide | Nitrogen Dioxide | Phosphine | Sulfur Dioxide | Carbon Monoxide | CO | O2 |
Detection Principle | Electrochemical | ||||||
Part# | 73-0071 | 73-0073 | 73-0079 | 73-0083 | 73-0067 | 73-0069 | |
Detection Range (Increments) |
0 ~ 30.0 ppm (0.1 ppm) |
0 ~ 20.00 ppm (0.05 ppm) |
0 ~ 20.00 ppm (0.01 ppm) |
0 ~ 100.0 ppm (0.05 ppm) |
0 ~ 2000 ppm (1 ppm) |
0 ~ 40% (0.1%) |
|
Alarm Set Points | 1st: 5.0 ppm 2nd: 10.0 ppm 3rd: 30.0 ppm TWA: 4.7 ppm STEL: 10 ppm |
1st: 2.00 ppm 2nd: b4.00 ppm 3rd: 20.00 ppm TWA: 0.50 ppm STEL: 1.00 ppm |
1st: 0.30 ppm 2nd: 0.60 ppm 3rd: 0.60 ppm TWA: 0.30 ppm STEL: 1.00 ppm |
1st: 2.00 ppm 2nd: 5.00 ppm 3rd: 100.00 ppm TWA: 2.00 ppm STEL 5.00 ppm |
1st 25 ppm 2nd 50 ppm 3rd 1200 ppm TWA 25 ppm STEL 200 ppm |
L: 19.5 % LL: 18.0% H: 25.0 % |
|
Alarm Types | Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error |
||||||
Alarm Methods | Gas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration Trouble alarm: Flashing LED’s, intermittent buzzer, and display of error message STEL & TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration |
||||||
Gas Sampling | Diffusion | ||||||
Response Time | T90 in 30 seconds | ||||||
Accuracy (which ever is greater) |
± 10% of reading or ± 5 % of full scale |
< 300 ppm ± 5 % of reading > 300 ppm ± 20 % of reading |
< 25% ± 0.5 % > 25% ± 3.0 % |
||||
Data Logging | 10 second intervals = 10 hours, 5 minute intervals = 300 hours, 10 minute intervals = 600 hours | ||||||
Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings. | |||||||
Battery Options | Alkaline dry cell (2-AAA size) | ||||||
Continuous Operation | 3,000 hours (at 25°C, no backlight) | 6,200 hours | 4,600 hours | ||||
Safety Rating | ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D | ||||||
Enclosure | Dust and water resistant with IP-67 rating | ||||||
Dimensions & Weight | 2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g) | ||||||
Display | Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon | ||||||
Operating Temp. & Humidity | -4°F ~ 122°F (-20°C ~ 50°C); Humidity below 90% RH (non-condensing) |
||||||
Standard Accessories | • Rubber protective boot • Alligator clip • Data logging software • Alkaline batteries |
||||||
Optional Accessories | • Calibration cap • Wrist strap • Calibration kit • Belt clip • Data logging download cable |
||||||
Special Functions | • Manual backlight for LCD (automatically lit during alarm) • Peak hold, STEL & TWA |
||||||
Warranty | 3 Year warranty |
- Overview
-
Overview:
The 04 Series Single Gas Detector is designed to operate for many years because they have 2 preset alarms that are user adjustable.
Meanwhile, each version is also equipped with visual, audible, and vibration alarms as per the standard.
These sensors also have a life expectancy of over 3 years. In addition, they’re backed by a 3-year warranty.
Furthermore, every 04 Series single gas detector is impact, dust, and water resistant with an IP-67 rating. As a result, these instruments are safe for use in hazardous locations, classified as intrinsically safe IECEx/ATEX.
- Specifications
-
Specifications:
Model Name SC-04 HCN SC-04 NO2 SC-04 PH3 SC-04 SO2 CO-04 (-H2) CX-04 Gas Detected Hydrogen Cyanide Nitrogen Dioxide Phosphine Sulfur Dioxide Carbon Monoxide CO O2 Detection Principle Electrochemical Part# 73-0071 73-0073 73-0079 73-0083 73-0067 73-0069 Detection Range
(Increments)0 ~ 30.0 ppm
(0.1 ppm)0 ~ 20.00 ppm
(0.05 ppm)0 ~ 20.00 ppm
(0.01 ppm)0 ~ 100.0 ppm
(0.05 ppm)0 ~ 2000 ppm
(1 ppm)0 ~ 40%
(0.1%)Alarm Set Points 1st: 5.0 ppm
2nd: 10.0 ppm
3rd: 30.0 ppm
TWA: 4.7 ppm
STEL: 10 ppm1st: 2.00 ppm
2nd: b4.00 ppm
3rd: 20.00 ppm
TWA: 0.50 ppm
STEL: 1.00 ppm1st: 0.30 ppm
2nd: 0.60 ppm
3rd: 0.60 ppm
TWA: 0.30 ppm
STEL: 1.00 ppm1st: 2.00 ppm
2nd: 5.00 ppm
3rd: 100.00 ppm
TWA: 2.00 ppm
STEL 5.00 ppm1st 25 ppm
2nd 50 ppm
3rd 1200 ppm
TWA 25 ppm
STEL 200 ppmL: 19.5 %
LL: 18.0%
H: 25.0 %Alarm Types Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA
Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range errorAlarm Methods Gas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration
Trouble alarm: Flashing LED’s, intermittent buzzer, and display of error message
STEL & TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibrationGas Sampling Diffusion Response Time T90 in 30 seconds Accuracy
(which ever is greater)± 10% of reading
or ± 5 % of full scale< 300 ppm ± 5 % of reading
> 300 ppm ± 20 % of reading< 25% ± 0.5 %
> 25% ± 3.0 %Data Logging 10 second intervals = 10 hours, 5 minute intervals = 300 hours, 10 minute intervals = 600 hours Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings. Battery Options Alkaline dry cell (2-AAA size) Continuous Operation 3,000 hours (at 25°C, no backlight) 6,200 hours 4,600 hours Safety Rating ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D Enclosure Dust and water resistant with IP-67 rating Dimensions & Weight 2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g) Display Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon Operating Temp. & Humidity -4°F ~ 122°F (-20°C ~ 50°C);
Humidity below 90% RH (non-condensing)Standard Accessories • Rubber protective boot • Alligator clip • Data logging software
• Alkaline batteriesOptional Accessories • Calibration cap • Wrist strap
• Calibration kit • Belt clip • Data logging download cableSpecial Functions • Manual backlight for LCD (automatically lit during alarm)
• Peak hold, STEL & TWAWarranty 3 Year warranty - Downloads
-
- Accessories