Features:
Stand Alone Station:
- Stand-alone station (no PC Required)
- Charging
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/archiving bump test and calibration records
Multi Module System
- Multiple modules connected to a PC (10 max)
- Charging
- Calibration
- Bump Test
- Configure GX-2012 parameters
- 2 Calibration gas ports
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Automatic calibration/bump test option
- Windows 7 compatible
Application/s:
- Personal monitoring
- Confined space entry
- Refineries / petrochemical
- Chemical plants
- Hazardous material
- Water / wastewater treatment
- Fire services
- Mining
Overview of the SDM-2012 Calibration Station:
The SDM-2012 Calibration Station is a versatile maintenance tool that automates the service of a GX-2012 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Specifications of the SDM-2012 Calibration Station:
Input Power | 12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. |
Environmental Conditions | • For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
Applicable Instruments | GX-2012 and Gas Tracer |
Maximum Number of Records Saved | 200 (stand-alone) |
Number of Calibration Gas Cylinders | Up to two calibration gas cylinders per bump test or calibration at a time |
Standard Accessories |
|
- Overview
-
Overview of the SDM-2012 Calibration Station:
The SDM-2012 Calibration Station is a versatile maintenance tool that automates the service of a GX-2012 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
- Specifications
-
Specifications of the SDM-2012 Calibration Station:
Input Power 12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. Environmental Conditions • For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing Applicable Instruments GX-2012 and Gas Tracer Maximum Number of Records Saved 200 (stand-alone) Number of Calibration Gas Cylinders Up to two calibration gas cylinders per bump test or calibration at a time Standard Accessories - AC Adapter
- USB Flash Drive
- Single Module Data Viewer Software
- SDM Docking Station PC Controller Software
- Inlet Air Filter
- Instruction Manual
- 10 Foot Long Exhaust Tube
- Two 3 Foot Long Tubes for GAS 1 and GAS 2
Fittings - 3 T-Fittings for PC Controlled Configuration
- USB Cable, Type A to Type B
- Downloads
-