Features:
Single Station Mode:
- Stand-alone station (no connection to PC required)
- Charging (NiMH batteries)
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copying to USB flash drive
- Includes PC software for viewing/archiving bump test and calibration records
Multiple Station Mode
- Multiple modules connected to a PC (10 max)
- Charging
- Software controlled Calibration
- Software controlled Bump Test
- Save Bump Test and Calibration records to a database for viewing and printing
- Software controlled data retrieval
- Automatic calibration/bump test option
- All records saved to database archive
- Windows 7 compatible
- Archive data to network location
Application/s:
- Portable Monitoring
- Oxygen Monitoring
Overview of the SDM-E2 Calibration Station for the Eagle2 gas detector
The SDM-E2 Calibration Station is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Specifications for the SDM-E2 Calibration Station
Input Power |
AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard |
Environmental Conditions |
• For Indoor Use Only • -10° C to 40° C, below 80% relative humidity, non condensing |
Applicable Instrument |
Eagle 2 |
Maximum Number of Records Saved |
200 |
Calibration Gas Ports |
Connect up to 2 calibration gas cylinders to each station |
Standard Accessories |
• AC adapter • USB flash drive • Single module data viewer software • SDM Docking station PC controller software • Inlet air filter • Instrument manual • 10’ exhaust tube |
- Overview
-
Overview of the SDM-E2 Calibration Station for the Eagle2 gas detector
The SDM-E2 Calibration Station is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
- Specifications
-
Specifications for the SDM-E2 Calibration Station
Input Power
AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard
Environmental Conditions
• For Indoor Use Only
• -10° C to 40° C, below 80% relative humidity, non condensing
Applicable Instrument
Eagle 2
Maximum Number of Records Saved
200
Calibration Gas Ports
Connect up to 2 calibration gas cylinders to each station
Standard Accessories
• AC adapter
• USB flash drive
• Single module data viewer software
• SDM Docking station PC controller software
• Inlet air filter
• Instrument manual
• 10’ exhaust tube