Smart Transmitter Detector – SD-1
Smart Transmitter Detector features state-of-the-art gas detectors with durable flameproof enclosure, maximum safety in hydrogen/ acethylene atmospheres.
Smart Transmitter Detector features state-of-the-art gas detectors with durable flameproof enclosure, maximum safety in hydrogen/ acethylene atmospheres.
Our SD-1 line of smart transmitters feature state-of-the-art gas detectors with durable flameproof enclosure, maximum safety, especially in hydrogen/ acethylene atmospheres. A simple magnetic control key is placed over clear marked positions on the surface plate to test and adjust the instrument without opening the transmitter in situations with danger of explosion. This “single-man-calibration” is already in use and applicable with other Control Equipment gas detectors for easy maintenance.
Model |
SD-1GP |
SD-1RI |
SD-1GH |
SD-1EC |
SD-1OX |
Detection principle | Catalytic | Infrared | Semiconductor | Electrochemical | Galvanic Cell |
Measuring gas | Variety of hydrocarbons |
See datasheet |
CO/H2S | Oxygen | |
Measuring range |
0 -100% LEL |
CO: 0-75ppm H2S: 0-30ppm |
0 -25 vol% |
||
Alarm setting | 2 programmable alarm set points/increasing/decreasing/latching/ self resetting/on delays/off delays/energised/energised | ||||
Alarm contacts | Normally open or normally closed | ||||
Sampling method | Diffusion (Flow adapter and air aspiration available) | ||||
Display | 4 digit Digital LED | ||||
Output | 4-20 mA or HART (optional without 4-20 mA) | ||||
Relay | 1 Relay with 4-20 mA versions or No relay with HART versions | ||||
Contact capacity | 30 VDC 0.5A or 120 VAC 0.5A (load resistance) | ||||
Fail alert Self diagnosis | Circuit failure / Sensor failure | ||||
Fail alert display | Fail lamp (Yellow) | ||||
Power source | 24VDC (17VDC ~ 26.4VDC) | ||||
Operating Temperature & humidity | -20 ~ + 60°C / below 95% RH (non condensing), (SD-1EC Below 80% RH) | ||||
Dimension & Weight | 148(W) x 161(H) x 88(D) mm, Approx. 2.0kg | ||||
Approvals
**Applied to SD-1GP for H2, CH4, i-C4H10, C3H8 |
Exd II CT5,ATEX **
IECEx EN60079-29-1 |
CML 15ATEX1034 IECEX, SIL2 | Exd II CT5,ATEX, IECEx | DEKRA 13ATEX0035 IECEx DEK 13.0024X, SIL2 |
Our SD-1 line of smart transmitters feature state-of-the-art gas detectors with durable flameproof enclosure, maximum safety, especially in hydrogen/ acethylene atmospheres. A simple magnetic control key is placed over clear marked positions on the surface plate to test and adjust the instrument without opening the transmitter in situations with danger of explosion. This “single-man-calibration” is already in use and applicable with other Control Equipment gas detectors for easy maintenance.
Model |
SD-1GP |
SD-1RI |
SD-1GH |
SD-1EC |
SD-1OX |
Detection principle | Catalytic | Infrared | Semiconductor | Electrochemical | Galvanic Cell |
Measuring gas | Variety of hydrocarbons |
See datasheet |
CO/H2S | Oxygen | |
Measuring range |
0 -100% LEL |
CO: 0-75ppm H2S: 0-30ppm |
0 -25 vol% |
||
Alarm setting | 2 programmable alarm set points/increasing/decreasing/latching/ self resetting/on delays/off delays/energised/energised | ||||
Alarm contacts | Normally open or normally closed | ||||
Sampling method | Diffusion (Flow adapter and air aspiration available) | ||||
Display | 4 digit Digital LED | ||||
Output | 4-20 mA or HART (optional without 4-20 mA) | ||||
Relay | 1 Relay with 4-20 mA versions or No relay with HART versions | ||||
Contact capacity | 30 VDC 0.5A or 120 VAC 0.5A (load resistance) | ||||
Fail alert Self diagnosis | Circuit failure / Sensor failure | ||||
Fail alert display | Fail lamp (Yellow) | ||||
Power source | 24VDC (17VDC ~ 26.4VDC) | ||||
Operating Temperature & humidity | -20 ~ + 60°C / below 95% RH (non condensing), (SD-1EC Below 80% RH) | ||||
Dimension & Weight | 148(W) x 161(H) x 88(D) mm, Approx. 2.0kg | ||||
Approvals
**Applied to SD-1GP for H2, CH4, i-C4H10, C3H8 |
Exd II CT5,ATEX **
IECEx EN60079-29-1 |
CML 15ATEX1034 IECEX, SIL2 | Exd II CT5,ATEX, IECEx | DEKRA 13ATEX0035 IECEx DEK 13.0024X, SIL2 |