Features:
- Measures and monitors four fumigation gases
- Complete job management system & reporting
- Measure 1, 2, or 3 sample points consecutively
- Manage multiple jobs in run/suspend mode (up to 99) or a single job running continuously
- Email finalised job data report to nominated recipients
- Save all job data electronically
- Built in sample pump
- Continuous operation 25+ hours on battery
- Bluetooth and WiFi enabled
- Lightweight and portable
- GPS location
Application/s:
-
Shipping Containers
-
Vessels
-
Grain
-
Timber
Overview of the FumigationMate – Fumigation Gas Monitor :
The FumigationMate is a four gas 3 channel Fumigation Gas Monitor with a powerful, user friendly integrated fumigation job management system providing secure measurement, collection, processing and reporting of all required fumigation data.
3 Sample lines
Any one of four common fumigation gases can be selected by the operator for the specific job application. Up to 3 sample lines can be attached simultaneously. Measurement time of each sample point in the job sequence is selectable by the operator.
Rugged design
FumigationMate’s rugged design enables it to be used in most applications, including challenging field environments. It is operator friendly and very portable.
Long battery life
This instrument can operate for over 25 hours on a single battery charge. All variables can be selected via the touchscreen on the FumigationMate. Up to 99 fumigation jobs can be set up prior to commencement of fumigation.
Multiple jobs
Once the fumigation process is initiated, the operator can pause a particular job and move to another job and initiate another fumigation. The instrument can be returned to each job multiple times to collect additional data.
All in one
The instrument can also be run continuously on one job to record the entire fumigation process. At the end of each fumigation the operator ends the monitoring and a complete fumigation report can be emailed to selected addresses.
Specifications for the Fumigation Gas Monitor:
Gases Measured |
• Methyl Bromide (CH3Br) in air 0-200g/m3 (0-200oz/1,000 cu. ft)
• Phosphine (PH3) in air 0-50g/m3 (0-50oz/1,000 cu. ft.) • Sulfuryl Fluoride (SO2F2) in air 0-200g/m3 (0-200oz/1,000 cu. ft.) • Cyanogen (C2N2) in air 0-50g/m3 • Cyanogen (C2N2) in air 0-300g/m3 |
Detection Principle |
Optical Interferometric |
Sampling Method |
Sample-draw by internal pump |
Sample Inputs |
1-3 (operator selectable) |
Job Management |
Integrated FumiNav management system collects data without operator input |
Job Monitoring |
Continuous or multi-job handling (up to 99) |
Job Reporting |
Data is electronically reported via transmission on job completion |
Display |
200mm (8”) touchscreen |
Filters |
Refillable Soda Lime CO2 filter supplied as standard |
Power Supply |
• Rechargeable battery for 25+ hours operation
• Continuous operation when connected to 85 – 264 VAC 50/60 HZ |
Environmental |
0°C ~ +50°C [ 32°F ~ 122°F ]; 0-95% RH (non condensing) |
Enclosure |
Polypropylene |
Dimensions |
W 417mm / 16.4″ D 221mm / 8.7″ H 334mm / 13.2″ |
Weight |
8kg / 18lb |
Warranty |
12 months |
Downloads for the Fumigation Gas Monitor:
Manual:
Specifications:
Videos:
- Overview
-
Overview of the FumigationMate – Fumigation Gas Monitor :
The FumigationMate is a four gas 3 channel Fumigation Gas Monitor with a powerful, user friendly integrated fumigation job management system providing secure measurement, collection, processing and reporting of all required fumigation data.
3 Sample lines
Any one of four common fumigation gases can be selected by the operator for the specific job application. Up to 3 sample lines can be attached simultaneously. Measurement time of each sample point in the job sequence is selectable by the operator.
Rugged design
FumigationMate’s rugged design enables it to be used in most applications, including challenging field environments. It is operator friendly and very portable.
Long battery life
This instrument can operate for over 25 hours on a single battery charge. All variables can be selected via the touchscreen on the FumigationMate. Up to 99 fumigation jobs can be set up prior to commencement of fumigation.
Multiple jobs
Once the fumigation process is initiated, the operator can pause a particular job and move to another job and initiate another fumigation. The instrument can be returned to each job multiple times to collect additional data.
All in one
The instrument can also be run continuously on one job to record the entire fumigation process. At the end of each fumigation the operator ends the monitoring and a complete fumigation report can be emailed to selected addresses.
- Specifications
-
Specifications for the Fumigation Gas Monitor:
Gases Measured
• Methyl Bromide (CH3Br) in air 0-200g/m3 (0-200oz/1,000 cu. ft) • Phosphine (PH3) in air 0-50g/m3 (0-50oz/1,000 cu. ft.)
• Sulfuryl Fluoride (SO2F2) in air 0-200g/m3 (0-200oz/1,000 cu. ft.)
• Cyanogen (C2N2) in air 0-50g/m3
• Cyanogen (C2N2) in air 0-300g/m3
Detection Principle
Optical Interferometric Sampling Method
Sample-draw by internal pump Sample Inputs
1-3 (operator selectable) Job Management
Integrated FumiNav management system collects data without operator input Job Monitoring
Continuous or multi-job handling (up to 99) Job Reporting
Data is electronically reported via transmission on job completion Display
200mm (8”) touchscreen Filters
Refillable Soda Lime CO2 filter supplied as standard Power Supply
• Rechargeable battery for 25+ hours operation • Continuous operation when connected to 85 – 264 VAC 50/60 HZ
Environmental
0°C ~ +50°C [ 32°F ~ 122°F ]; 0-95% RH (non condensing) Enclosure
Polypropylene Dimensions
W 417mm / 16.4″ D 221mm / 8.7″ H 334mm / 13.2″ Weight
8kg / 18lb Warranty
12 months - Downloads
-
Downloads for the Fumigation Gas Monitor: