Portable Flammable Gas Monitor with Low PPM – GX-2012GT

Portable Flammable Gas Detector with Low PPM

Features:

  • Monitors ppm, LEL, % vol methane, O2 and CO
  • PPM leak detector, detects down to 10ppm CH4
  • “Leak tracker” audible/visual alarm mode
  • 0 to 100% volume methane option
  • Auto-ranging display of % LEL and % volume
  • Barhole test mode
  • Bump test reminder option
  • Snap-logging – on demand data recording
  • Pump pause on demand extends battery life
  • Internal sample drawing pump with up to 15m range
  • Vibration, visual, and audible alarms
  • Automatic backlight during alarms
  • Calibration reminder with lock out option
  • Lithium ion or alkaline power source (interchangeable)
  • Quick charge (complete charge in 90 minutes)
  • Glove friendly large buttons
  • Alarm latching or non-latching
  • High impact protective rubber overmoulding
  • Up to 600 hours of data logging with alarm trends
  • Autocalibration or single calibration
  • TWA and STEL readings with lunch-break mode
  • Intrinsically safe, IECEx, ATEX

Application/s:

  • Personal monitoring
  • Confined space entry
  • Refineries / petrochemical
  • Chemical plants
  • Hazardous material
  • Water / wastewater treatment
  • Fire services
  • Mining

Built around high-quality micro-sensor technology, the GX-2012GT portable flammable gas monitor with low PPM is Control Equipment’s smallest personal 5 sensor monitor with a built in sample pump. Weighing only 350g, it has many features which set the GX-2012GT apart from the competition.

Built around high-quality micro-sensor technology, the GX-2012GT portable flammable gas monitor with low PPM is Control Equipment’s smallest personal 5 sensor monitor with a built in sample pump. Weighing only 350g, it has many features which set the GX-2012GT portable flammable gas monitor with low PPM apart from the competition. It can monitor the standard gas safety hazards for gas/pipeline operations, (LEL combustibles, oxygen content and carbon monoxide), and it also has a high-sensitivity ppm CH4 leak tracker mode which reads down to 10 ppm.

It can also measure 100% volume methane and dynamically display either % LEL, or % volume with its auto-ranging ability.

The GX-2012GT portable flammable gas monitor with low PPM is excellent for gas line purge testing and detection of small gas leaks.

The GX-2012GT portable flammable gas monitor with low PPM models’ large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Other standard mode alarm types include vibration, visual, and audible alarms that can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012GT continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012GT can interchangeably operate on either a Li-Ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack. Calibration and bump test intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibrations can be performed automatically or individually in single calibration mode. The GX-2012GT is also compatible with the economical SDM-2012 single channel calibration station.

Specifications:

Gas Detected Combustible Gases
(Methane as standard)
% Volume
Methane
PPM
Methane
Oxygen (O2) Carbon Monoxide (CO)
Detection Principle Catalytic combustion Thermal conductivity MOS
catalytic
Galvanic cell Electro- chemical cell
Detection Range 0 ~ 100% LEL 0 ~ 100% Vol. 0 ~ 5000 ppm
optional 10,000 ppm range version available
0 ~ 40% Vol. 0 ~ 500 ppm
Accuracy Statement
(whichever is greater)
± 5% of reading or
± 2% LEL
± 5% of reading or ± 2% of full scale ± 10% of reading or ± 50 ppm CH4 ± 0.5% O2 ± 5% of reading or ± 5 ppm CO
Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter
Display Digital LCD with 7 segments, auto backlight during alarm
Preset Alarms
(User Adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
No alarms for
% Vol. CH4
Increasing tone/light pulse as concentration increases Low alarm 19.5% High alarm 23.5% Over alarm 40.0% 1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
Alarms Types Leak Tracker Mode: Escalating audible/visual alarm, changes with gas level (audible can be turned off)
Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error
Alarm Methods Gas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity -20°C to +50°C (-4°F to +122°F)
0 to 95% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Alkaline battery: 15 hours Li-Ion battery: 10 hours
70°F (21°C)
Power Source Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable
Safety Rating ATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.
Dimension & Weight Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces)
Case Material High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding
Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT
Standard Accessories • Belt clip • Rubber nozzle, 2.5” • Datalogging software
• 10” Probe • Manual • Quick reference card
• 10’ Hose • Training CD
Optional Accessories • SDM-2012 calibration stations • Calibration kit
• Li-Ion battery pack • AC or DC Charger
• Sample draw hoses (10’ standard, up to 50’ max. available) • Carrying case
Configurations 1, 2, 3, 4, or 5 sensor units
Li-Ion or alkaline battery pack options
Warranty Two years material and workmanship

Downloads:

 

Specifications:

GX-2012GT Datasheet

 

Certification:

IECEx Certificate

ATEX Certificate

Videos:

Accessories:

Sample Draw Pump GX-2012Calibration Station SDM-2012

Calibration Station

Sampling Hose and Probe

Sampling Hose & Probe

Sample Draw Gas Monitor GX-2012 Charger

Li-Ion Battery Pack

Overview

Built around high-quality micro-sensor technology, the GX-2012GT portable flammable gas monitor with low PPM is Control Equipment’s smallest personal 5 sensor monitor with a built in sample pump. Weighing only 350g, it has many features which set the GX-2012GT apart from the competition.

Built around high-quality micro-sensor technology, the GX-2012GT portable flammable gas monitor with low PPM is Control Equipment’s smallest personal 5 sensor monitor with a built in sample pump. Weighing only 350g, it has many features which set the GX-2012GT portable flammable gas monitor with low PPM apart from the competition. It can monitor the standard gas safety hazards for gas/pipeline operations, (LEL combustibles, oxygen content and carbon monoxide), and it also has a high-sensitivity ppm CH4 leak tracker mode which reads down to 10 ppm.

It can also measure 100% volume methane and dynamically display either % LEL, or % volume with its auto-ranging ability.

The GX-2012GT portable flammable gas monitor with low PPM is excellent for gas line purge testing and detection of small gas leaks.

The GX-2012GT portable flammable gas monitor with low PPM models’ large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Other standard mode alarm types include vibration, visual, and audible alarms that can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012GT continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012GT can interchangeably operate on either a Li-Ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack. Calibration and bump test intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibrations can be performed automatically or individually in single calibration mode. The GX-2012GT is also compatible with the economical SDM-2012 single channel calibration station.

Specifications

Specifications:

Gas Detected Combustible Gases
(Methane as standard)
% Volume
Methane
PPM
Methane
Oxygen (O2) Carbon Monoxide (CO)
Detection Principle Catalytic combustion Thermal conductivity MOS
catalytic
Galvanic cell Electro- chemical cell
Detection Range 0 ~ 100% LEL 0 ~ 100% Vol. 0 ~ 5000 ppm
optional 10,000 ppm range version available
0 ~ 40% Vol. 0 ~ 500 ppm
Accuracy Statement
(whichever is greater)
± 5% of reading or
± 2% LEL
± 5% of reading or ± 2% of full scale ± 10% of reading or ± 50 ppm CH4 ± 0.5% O2 ± 5% of reading or ± 5 ppm CO
Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter
Display Digital LCD with 7 segments, auto backlight during alarm
Preset Alarms
(User Adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
No alarms for
% Vol. CH4
Increasing tone/light pulse as concentration increases Low alarm 19.5% High alarm 23.5% Over alarm 40.0% 1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
Alarms Types Leak Tracker Mode: Escalating audible/visual alarm, changes with gas level (audible can be turned off)
Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error
Alarm Methods Gas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity -20°C to +50°C (-4°F to +122°F)
0 to 95% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Alkaline battery: 15 hours Li-Ion battery: 10 hours
70°F (21°C)
Power Source Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable
Safety Rating ATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.
Dimension & Weight Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces)
Case Material High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding
Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT
Standard Accessories • Belt clip • Rubber nozzle, 2.5” • Datalogging software
• 10” Probe • Manual • Quick reference card
• 10’ Hose • Training CD
Optional Accessories • SDM-2012 calibration stations • Calibration kit
• Li-Ion battery pack • AC or DC Charger
• Sample draw hoses (10’ standard, up to 50’ max. available) • Carrying case
Configurations 1, 2, 3, 4, or 5 sensor units
Li-Ion or alkaline battery pack options
Warranty Two years material and workmanship
Downloads

Downloads:

 

Specifications:

GX-2012GT Datasheet

 

Certification:

IECEx Certificate

ATEX Certificate

Videos

Videos:

Accessories

Accessories:

Sample Draw Pump GX-2012Calibration Station SDM-2012

Calibration Station

Sampling Hose and Probe

Sampling Hose & Probe

Sample Draw Gas Monitor GX-2012 Charger

Li-Ion Battery Pack

Enquire Now

    Name*

    Phone*

    Location*

    If Other

    Email*

    How did you hear about us?*

    What are you interested in?*

    Message