GX-6000 Benzene Personal PID Gas Monitor

GX-6000 - Benzene Personal PID gas monitor

 Features:

  • Benzene specific measurement
    • 0.01 – 50 ppm with 10.0 eV PID lamp and pre-filter tube
  • Benzene select mode takes timed samples using pre-filter tube
  • Long break through times for benzene filter tubes
  • 10.0 eV Selective PID sensor
    • 0 – 100 ppm VOC range
    • Library of over 300 VOC’s including BTEX
    • Humidity resistant
  • Easily switched VOC target gas
    • Favorite list of 30 VOC’s
    • Recently used list of 8 VOC’s
  • Dual channel PIDs utilizing both 10.0 & 10.6 PID sensors
  • 2 smart sensor slots auto recognize PID, IR, and super toxic sensors
  • Internal sample pump
  • Dust & Water resistant IP-67 design
  • Interchangeable battery packs Li-ion / alkaline
  • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours

Application/s:

  • Petroleum / Oil refining

  • Chemical manufacturing

  • Rubber & Tire manufacturing

  • Coke & Coal manufacturing

  • Fuel Storage & Tank Farms

  • Hazmat response teams

Overview of the Benzene Personal PID gas monitor:

The GX-6000 personal Benzene PID gas monitor is the lightest and smallest Benzene monitor created, weighing in at only 600 grams with the rubber boot.

Simply put, the GX-6000 is a game changer with Benzene Specific measuring mode. With a library of over 300 VOC’s and the addition of the highly selective 10.0 eV PID sensor, the GX-6000 can now detect the BTEX (benzene, toluene, ethylbenzene, and xylene) family of VOC’s up to 100 ppm. By using  filtering tubes and the tube holder, the GX-6000 can monitor specifically for Benzene at a range of 0 – 50ppm (with resolutions as small as 0.01) by filtering out all other VOC’s. The filter tube holder has a unique break away design for accidental damage. The filter tube also has a safe and convenient glass breaker for the filter tube tips.

The GX-6000 is the only PID instrument in the market with the ability to utilise two PID sensors in one instrument. When using the broad range 10.6eV PID for preliminary investigation, it is possible to switch to benzene mode for a highly accurate measurement.

The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.

Specifications:

Alarm Types Gas alarm Man-down Trouble
Low and high adjustable 1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration range

 

Sample Method Sample draw pump, flow rate 0.45 LPM, 30m sample range
Display Digital LCD, autobacklite, peak bar display, auto display rotation, and customize order of gases
Audible Alarm 95 dB at 1 ft.
Languages English, German, Japanese, Korean, Russian
Continuous
Operation *
14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

8 hours Alkaline battery pack (3 AA size within each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50?), 0- 95% RH non condensing
Dimensions / Weight 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
14 ounce (400g) (with lithium battery pack)
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design /

Approvals

Explosion proof: IECEx , ATEX
 

Standard
Features

  • 2 Smart sensors slots auto recognise sensor changes
  • Library of over 600 VOC’s
  • User defined VOC list. Up to 30 frequently used
  • Recent VOC list for last 8 selected gases
  • Pump and circuit status indicators
  • User & station ID selection menu
  • Datalogging (interval, alarm trend, station and user ID)
  • Snap logging – on demand data logging
  • Demand zero / Auto zero
  • BUMP and CAL expiration alarm
  • Flashlight
  • IrDA communication
  • LEL sensor protection mode
Standard
Accessories
  • Rubber boot
  • Belt clip
  • Hand strap
  • Tapered nozzle
  • Probe with hydrphobic filter and 3’ teflon lined hose
Optional
Accessories
  • Lithium-ion battery pack & charger / alkaline battery charger
  • Filter set • IrDA cable
Warranty Two years material (including sensors) and workmanship. One year for PID sensor
Gas Measuring Range Minimum Display Alarm Set Points Accuracy
* Which ever is greater
PID Sensors
10.6 PID Lamp
600
VOC’s
0 – 50,000 ppb 1 ppb
(< 5000 ppb)
10 ppb
(> 5,000 ppb)
A1: 5,000 ppb +5% of full scale
A2: 10,000 ppb
0 – 6,000 ppm 0.1 ppm
(< 600 ppm)
1 ppm
(> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm
10.0 PID Lamp

Benzene Specific No Alarms
300 VOC’s 0 – 100 ppm

Benzene Specific
0.1 – 50 ppm
0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 50 ppm)
no alarms
300 VOC’s
0 – 100 ppm
0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 100 ppm)
A1: 5 ppm
A2: 10 ppm
Catalytic
Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL ± 5% of
reading or ± 2% LEL (*)
A2: 50%LEL
Galvanic
Oxygen (O2) 0 – 40% Vol. 0.1% Vol. A1: 19.5 Vol. ± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO) 0 – 500 ppm 1 ppm A1: 25 ppm ± 5% of reading or ± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S) 0 – 100 ppm 0.5 ppm A1: 5.0 ppm ± 5% of reading or± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)* 0 – 75 ppm

0 – 400 ppm

0.5 ppm

5 ppm

A1: 25 ppm ± 10% of reading or ± 5% of full scale (*)
A2: 50 ppm
Chlorine (Cl2)* 0 – 3 ppm

0 – 10 ppm

0.05 ppm

0.1 ppm

A1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN) 0 – 15 ppm 0.1 ppm A1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2) 0 – 20 ppm 0.05 ppm A1: 3 ppm
A2: 6 ppm
Sulfur Dioxide (SO2) 0 – 100 ppm A1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)

 

0 – 10% vol 25 ppm 0.2% A1: 5,000 ppm ± 5% of reading or ± 2% of full scale (*)
TWA 5,000 ppm
STEL 10,000
Methane (CH4)* 0 – 100% LEL/

0 – 100% Vol.

Vol. 1% LEL /
0.5% Vol
A1: 10% LEL
Hydrocarbons** 0 – 100% LEL/
0 – 30% Vol.
A2: 50% LEL
PID Sensors
VOC 0 – 50,000 ppb 1 ppb
(< 5000 ppb)
10 ppb
(> 5,000 ppb)
A1: 5,000 ppb +10% of reading + 1 digit
A2: 10,000 ppb
0 – 6,000 ppm 0.1 ppm
(< 600 ppm)
1 ppm
(> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm

 

Downloads:


Manual

Specifications:

GX-6000 Webinar

One to Six Monitor Calibration Station SDM-6000

SDM-6000

Sampling Hose and Probe

Sampling Hose & Probe

GX-6000 - Benzene Personal PID gas monitor

Red Boot

Overview

Overview of the Benzene Personal PID gas monitor:

The GX-6000 personal Benzene PID gas monitor is the lightest and smallest Benzene monitor created, weighing in at only 600 grams with the rubber boot.

Simply put, the GX-6000 is a game changer with Benzene Specific measuring mode. With a library of over 300 VOC’s and the addition of the highly selective 10.0 eV PID sensor, the GX-6000 can now detect the BTEX (benzene, toluene, ethylbenzene, and xylene) family of VOC’s up to 100 ppm. By using  filtering tubes and the tube holder, the GX-6000 can monitor specifically for Benzene at a range of 0 – 50ppm (with resolutions as small as 0.01) by filtering out all other VOC’s. The filter tube holder has a unique break away design for accidental damage. The filter tube also has a safe and convenient glass breaker for the filter tube tips.

The GX-6000 is the only PID instrument in the market with the ability to utilise two PID sensors in one instrument. When using the broad range 10.6eV PID for preliminary investigation, it is possible to switch to benzene mode for a highly accurate measurement.

The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.

Specifications

Specifications:

Alarm Types Gas alarm Man-down Trouble
Low and high adjustable 1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration range

 

Sample Method Sample draw pump, flow rate 0.45 LPM, 30m sample range
Display Digital LCD, autobacklite, peak bar display, auto display rotation, and customize order of gases
Audible Alarm 95 dB at 1 ft.
Languages English, German, Japanese, Korean, Russian
Continuous
Operation *
14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

8 hours Alkaline battery pack (3 AA size within each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50?), 0- 95% RH non condensing
Dimensions / Weight 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
14 ounce (400g) (with lithium battery pack)
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design /

Approvals

Explosion proof: IECEx , ATEX
 

Standard
Features

  • 2 Smart sensors slots auto recognise sensor changes
  • Library of over 600 VOC’s
  • User defined VOC list. Up to 30 frequently used
  • Recent VOC list for last 8 selected gases
  • Pump and circuit status indicators
  • User & station ID selection menu
  • Datalogging (interval, alarm trend, station and user ID)
  • Snap logging – on demand data logging
  • Demand zero / Auto zero
  • BUMP and CAL expiration alarm
  • Flashlight
  • IrDA communication
  • LEL sensor protection mode
Standard
Accessories
  • Rubber boot
  • Belt clip
  • Hand strap
  • Tapered nozzle
  • Probe with hydrphobic filter and 3’ teflon lined hose
Optional
Accessories
  • Lithium-ion battery pack & charger / alkaline battery charger
  • Filter set • IrDA cable
Warranty Two years material (including sensors) and workmanship. One year for PID sensor
Detectable Ranges
Gas Measuring Range Minimum Display Alarm Set Points Accuracy
* Which ever is greater
PID Sensors
10.6 PID Lamp
600
VOC’s
0 – 50,000 ppb 1 ppb
(< 5000 ppb)
10 ppb
(> 5,000 ppb)
A1: 5,000 ppb +5% of full scale
A2: 10,000 ppb
0 – 6,000 ppm 0.1 ppm
(< 600 ppm)
1 ppm
(> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm
10.0 PID Lamp

Benzene Specific No Alarms
300 VOC’s 0 – 100 ppm

Benzene Specific
0.1 – 50 ppm
0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 50 ppm)
no alarms
300 VOC’s
0 – 100 ppm
0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 100 ppm)
A1: 5 ppm
A2: 10 ppm
Catalytic
Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL ± 5% of
reading or ± 2% LEL (*)
A2: 50%LEL
Galvanic
Oxygen (O2) 0 – 40% Vol. 0.1% Vol. A1: 19.5 Vol. ± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO) 0 – 500 ppm 1 ppm A1: 25 ppm ± 5% of reading or ± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S) 0 – 100 ppm 0.5 ppm A1: 5.0 ppm ± 5% of reading or± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)* 0 – 75 ppm

0 – 400 ppm

0.5 ppm

5 ppm

A1: 25 ppm ± 10% of reading or ± 5% of full scale (*)
A2: 50 ppm
Chlorine (Cl2)* 0 – 3 ppm

0 – 10 ppm

0.05 ppm

0.1 ppm

A1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN) 0 – 15 ppm 0.1 ppm A1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2) 0 – 20 ppm 0.05 ppm A1: 3 ppm
A2: 6 ppm
Sulfur Dioxide (SO2) 0 – 100 ppm A1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)

 

0 – 10% vol 25 ppm 0.2% A1: 5,000 ppm ± 5% of reading or ± 2% of full scale (*)
TWA 5,000 ppm
STEL 10,000
Methane (CH4)* 0 – 100% LEL/

0 – 100% Vol.

Vol. 1% LEL /
0.5% Vol
A1: 10% LEL
Hydrocarbons** 0 – 100% LEL/
0 – 30% Vol.
A2: 50% LEL
PID Sensors
VOC 0 – 50,000 ppb 1 ppb
(< 5000 ppb)
10 ppb
(> 5,000 ppb)
A1: 5,000 ppb +10% of reading + 1 digit
A2: 10,000 ppb
0 – 6,000 ppm 0.1 ppm
(< 600 ppm)
1 ppm
(> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm

 

Downloads

Downloads:


Manual

Specifications:

Videos

GX-6000 Webinar

Accessories
One to Six Monitor Calibration Station SDM-6000

SDM-6000

Sampling Hose and Probe

Sampling Hose & Probe

GX-6000 - Benzene Personal PID gas monitor

Red Boot

Enquire Now

    Name*

    Phone*

    Location*

    If Other

    Email*

    How did you hear about us?*

    What are you interested in?*

    Message