 Features:

  • Multi gas detection‐ 1 to 6 gases
  • Smart sensor—PID, EC, IR, OS
  • World smallest & lightest 6 gas monitor
  • Interchangeable power source Li‐Ion / Alkaline
  • Wide operation temp ‐20°C to 50°C
  • High water & dust proof level IP67
  • Various approvals IECEx, ATEX
  • Docking station SDM‐6000
  • New functions Full dot LCD / man down / panic alarm / LCD inversion / LED flashlight

Application/s:

  • Personal monitoring
  • Refineries/petrochemical
  • Wastewater treatment / confined space
  • Utilities
  • Chemical plants
  • Hazardous material
  • Water
  • Fire service

Overview of the personal multi gas detector:

Simply put, the GX-6000 is a game changer, because this powerful hand-held personal multi gas detector instrument is capable of simultaneously monitoring up to 6 gases.

Including the standard 4 confined space gases which incorporates combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.

PID Sensor

Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilising all 6 channels.

This one to six gas monitor with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard.

Choosing from the library is easy with a personalised favourites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s.

Rugged Design

The personal multi gas detector GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating.

With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives, and because of the vibration and loud audible alarms, the one to six personal monitor will easily alert users when needed.

Specifications:

Common Specifications
Alarm Types Gas Alarm Man-down Trouble
Low and high adjustable 1st – self reset
2nd – latching
Low flow Sensor connection Low battery Circuit error Calibration range
Sample Method Sample draw pump, flow rate 0.45 LPM 30 meter sample range
Display

 

Digital LCD, auto backlite, peak bar display, auto display rotation, and customise order of gases
Audible Alarm 95 dB at 30cm
Continuous Operation 24 hours on Lithium-ion battery pack
Complete recharge in 3 hours
8 hours Alkaline battery pack (3 AA size in each pack)
Operating Temp. & Humidity -20°C to +50°C, 0- 95% RH non-condensing

 

Dimensions 70mm W x 201mm H x 54mm D 600g (with lithium battery pack)
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design / Approvals

 

Explosion proof: IECEx , ATEX , TIIS , Explosion class : Ex ia IIB T4/T3 Ga -20°C ≤ Ta ≤ +50°C Ex ia IIC T4/T3 Ga -20°C ≤ Ta ≤ +50°C Others: CE Marking
Standard Features

 

2 Smart sensors slots auto recognize sensor changes

Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Data logging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight IrDA communication

LEL sensor protection mode

Standard Accessories • Taper nozzle Accessories

• Hand strap

• LCD protect nozzle

• Belt clip

• Rubber boot

• Li-Ion battery unit (BUL-6000)

Optional Accessories • Alkaline battery pack & charger
• Filter set
• IrDA cable
Warranty Two years material (including sensors) and workmanship. One year for PID sensor

Gases & Detectable Ranges

Gases & Detectable Ranges
 

Gas

 

Measuring Range

 

Minimum Display

 

Alarm Set Points

Accuracy (which ever is greater)
Catalytic
Hydrocarbons (CH4, std)  

0 – 100% LEL

 

1% LEL

A1: 5%LEL ± 5% of reading or ± 2% LEL
A2: 10%LEL
Galvanic
 

Oxygen (O2)

 

0 – 40% Vol.

 

0.1% Vol.

A1: 19.5 Vol.  

± 0.5% O2

A2: 23.5 Vol.
Electro Chemical
 

 

Carbon Monoxide (CO)

 

 

0 – 500 ppm

 

 

1 ppm

A1: 30 ppm  

± 5% of reading or

± 5 ppm

A2: 60 ppm
TWA: 30 ppm
STEL: 60 ppm
 

 

Hydrogen Sulfide (H2S)

 

 

0 – 100 ppm

 

 

0.5 ppm

A1: 10 ppm  

± 5% of reading or

± 2 ppm

A2: 15 ppm
TWA: 10 ppm
STEL: 15 ppm
Toxics (EC Sensors)
Ammonia (NH3) 0 – 400 ppm 0.5 ppm A1: 25 ppm  

 

 

± 10% of reading or

± 5% of full scale

A2: 35 ppm
Hydrogen Cyanide (HCN) 0 – 15 ppm 0.1      ppm A1:      5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2) 0 – 20 ppm  

 

0.05      ppm

A1:      3 ppm
A2:      5 ppm
Sulfur Dioxide (SO2) 0 – 99.90 ppm A1:      2 ppm
A2:      5 ppm
Phosphine

(PH3)

0 – 20 ppm* 0.2 ppm A1: 0.3 ppm
A2:      1 ppm
IR Sensors
 

 

Carbon Dioxide (CO2)

 

0 – 10,000 ppm

 

20 ppm

A1: 5,000 ppm  

 

 

 

± 5% of reading or

± 2% of full scale

TWA: 5,000 ppm
 

 

0 – 10% Vol.

 

 

0.02%

A1: 0.50% Vol
A2: 3.00% Vol
STEL: 3.00% Vol
TWA: 0.50% Vol
Methane (CH4) 0 – 100% LEL

0 – 100% Vol.

 

Vol. 1% LEL/

0.5% Vol

A1: 5% LEL

*

Hydrocarbons

(HC)

0 – 100% LEL

0 – 30% Vol.

A2: 10% LEL

*

PID Sensors
 

 

 

600

VOC

10.6 Lamp

 

0 – 50,000 ppb

1 ppb:

(< 5000 ppb)

10 ppb:

(> 5,000 ppb)

A1: 5,000 ppb  

 

 

 

 

 

 

 

 

± 10% of reading,

± 1 digit

A2: 10,000 ppb
 

0 – 6,000 ppm

0.1 ppm: (< 600 ppm)

1 ppm:

(> 600 ppm)

A1: 50 ppm
A2: 100 ppm
STEL: 100 ppm
TWA: 50 ppm
 

Benzene Specific

 

0.1 – 50 ppm

0.01 ppm

( 0 ~  10 ppm)

0.1 ppm (10 ~ 50 ppm)

No alarms
300 VOC’s

10.0 Lamp

 

0 – 100 ppm

0.01 ppm

( 0 ~  10 ppm)

0.1 ppm (10 ~ 100 ppm)

A1:  5 ppm

A2: 10 ppm

 

High Voltage

11.7 Lamp

 

0 – 1000 ppm

 

0.1 ppm

A1: 400 ppm

A2: 1,000 ppm

GX-6000

GX-6000 Webinar

One to Six Monitor Calibration Station SDM-6000

Calibration Station SDM-6000

Sampling Hose and Probe

Sampling Hose & Probe

CO2 Filter

Soda Lime for CO2 Zero

Charcoal Filter

Charcoal for PID Zero

Overview

Overview of the personal multi gas detector:

Simply put, the GX-6000 is a game changer, because this powerful hand-held personal multi gas detector instrument is capable of simultaneously monitoring up to 6 gases.

Including the standard 4 confined space gases which incorporates combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.

PID Sensor

Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilising all 6 channels.

This one to six gas monitor with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard.

Choosing from the library is easy with a personalised favourites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s.

Rugged Design

The personal multi gas detector GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating.

With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives, and because of the vibration and loud audible alarms, the one to six personal monitor will easily alert users when needed.

Specifications

Specifications:

Common Specifications
Alarm Types Gas Alarm Man-down Trouble
Low and high adjustable 1st – self reset
2nd – latching
Low flow Sensor connection Low battery Circuit error Calibration range
Sample Method Sample draw pump, flow rate 0.45 LPM 30 meter sample range
Display

 

Digital LCD, auto backlite, peak bar display, auto display rotation, and customise order of gases
Audible Alarm 95 dB at 30cm
Continuous Operation 24 hours on Lithium-ion battery pack
Complete recharge in 3 hours
8 hours Alkaline battery pack (3 AA size in each pack)
Operating Temp. & Humidity -20°C to +50°C, 0- 95% RH non-condensing

 

Dimensions 70mm W x 201mm H x 54mm D 600g (with lithium battery pack)
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design / Approvals

 

Explosion proof: IECEx , ATEX , TIIS , Explosion class : Ex ia IIB T4/T3 Ga -20°C ≤ Ta ≤ +50°C Ex ia IIC T4/T3 Ga -20°C ≤ Ta ≤ +50°C Others: CE Marking
Standard Features

 

2 Smart sensors slots auto recognize sensor changes

Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Data logging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight IrDA communication

LEL sensor protection mode

Standard Accessories • Taper nozzle Accessories

• Hand strap

• LCD protect nozzle

• Belt clip

• Rubber boot

• Li-Ion battery unit (BUL-6000)

Optional Accessories • Alkaline battery pack & charger
• Filter set
• IrDA cable
Warranty Two years material (including sensors) and workmanship. One year for PID sensor
Detection Ranges

Gases & Detectable Ranges

Gases & Detectable Ranges
 

Gas

 

Measuring Range

 

Minimum Display

 

Alarm Set Points

Accuracy (which ever is greater)
Catalytic
Hydrocarbons (CH4, std)  

0 – 100% LEL

 

1% LEL

A1: 5%LEL ± 5% of reading or ± 2% LEL
A2: 10%LEL
Galvanic
 

Oxygen (O2)

 

0 – 40% Vol.

 

0.1% Vol.

A1: 19.5 Vol.  

± 0.5% O2

A2: 23.5 Vol.
Electro Chemical
 

 

Carbon Monoxide (CO)

 

 

0 – 500 ppm

 

 

1 ppm

A1: 30 ppm  

± 5% of reading or

± 5 ppm

A2: 60 ppm
TWA: 30 ppm
STEL: 60 ppm
 

 

Hydrogen Sulfide (H2S)

 

 

0 – 100 ppm

 

 

0.5 ppm

A1: 10 ppm  

± 5% of reading or

± 2 ppm

A2: 15 ppm
TWA: 10 ppm
STEL: 15 ppm
Toxics (EC Sensors)
Ammonia (NH3) 0 – 400 ppm 0.5 ppm A1: 25 ppm  

 

 

± 10% of reading or

± 5% of full scale

A2: 35 ppm
Hydrogen Cyanide (HCN) 0 – 15 ppm 0.1      ppm A1:      5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2) 0 – 20 ppm  

 

0.05      ppm

A1:      3 ppm
A2:      5 ppm
Sulfur Dioxide (SO2) 0 – 99.90 ppm A1:      2 ppm
A2:      5 ppm
Phosphine

(PH3)

0 – 20 ppm* 0.2 ppm A1: 0.3 ppm
A2:      1 ppm
IR Sensors
 

 

Carbon Dioxide (CO2)

 

0 – 10,000 ppm

 

20 ppm

A1: 5,000 ppm  

 

 

 

± 5% of reading or

± 2% of full scale

TWA: 5,000 ppm
 

 

0 – 10% Vol.

 

 

0.02%

A1: 0.50% Vol
A2: 3.00% Vol
STEL: 3.00% Vol
TWA: 0.50% Vol
Methane (CH4) 0 – 100% LEL

0 – 100% Vol.

 

Vol. 1% LEL/

0.5% Vol

A1: 5% LEL

*

Hydrocarbons

(HC)

0 – 100% LEL

0 – 30% Vol.

A2: 10% LEL

*

PID Sensors
 

 

 

600

VOC

10.6 Lamp

 

0 – 50,000 ppb

1 ppb:

(< 5000 ppb)

10 ppb:

(> 5,000 ppb)

A1: 5,000 ppb  

 

 

 

 

 

 

 

 

± 10% of reading,

± 1 digit

A2: 10,000 ppb
 

0 – 6,000 ppm

0.1 ppm: (< 600 ppm)

1 ppm:

(> 600 ppm)

A1: 50 ppm
A2: 100 ppm
STEL: 100 ppm
TWA: 50 ppm
 

Benzene Specific

 

0.1 – 50 ppm

0.01 ppm

( 0 ~  10 ppm)

0.1 ppm (10 ~ 50 ppm)

No alarms
300 VOC’s

10.0 Lamp

 

0 – 100 ppm

0.01 ppm

( 0 ~  10 ppm)

0.1 ppm (10 ~ 100 ppm)

A1:  5 ppm

A2: 10 ppm

 

High Voltage

11.7 Lamp

 

0 – 1000 ppm

 

0.1 ppm

A1: 400 ppm

A2: 1,000 ppm

Downloads
Videos

GX-6000

GX-6000 Webinar

Accessories
One to Six Monitor Calibration Station SDM-6000

Calibration Station SDM-6000

Sampling Hose and Probe

Sampling Hose & Probe

CO2 Filter

Soda Lime for CO2 Zero

Charcoal Filter

Charcoal for PID Zero

Enquire Now

    Name*

    Phone*

    Location*

    If Other

    Email*

    How did you hear about us?*

    What are you interested in?*

    Message