Features:
- Multi gas detection‐ 1 to 6 gases
- Smart sensor—PID, EC, IR, OS
- World smallest & lightest 6 gas monitor
- Interchangeable power source Li‐Ion / Alkaline
- Wide operation temp ‐20°C to 50°C
- High water & dust proof level IP67
- Various approvals IECEx, ATEX
- Docking station SDM‐6000
- New functions Full dot LCD / man down / panic alarm / LCD inversion / LED flashlight
Application/s:
- Personal monitoring
- Refineries/petrochemical
- Wastewater treatment / confined space
- Utilities
- Chemical plants
- Hazardous material
- Water
- Fire service
Overview of the personal multi gas detector:
Simply put, the GX-6000 is a game changer, because this powerful hand-held personal multi gas detector instrument is capable of simultaneously monitoring up to 6 gases.
Including the standard 4 confined space gases which incorporates combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.
PID Sensor
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilising all 6 channels.
This one to six gas monitor with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard.
Choosing from the library is easy with a personalised favourites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s.
Rugged Design
The personal multi gas detector GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating.
With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives, and because of the vibration and loud audible alarms, the one to six personal monitor will easily alert users when needed.
Specifications:
Common Specifications | |||
Alarm Types | Gas Alarm | Man-down | Trouble |
Low and high adjustable | 1st – self reset 2nd – latching |
Low flow Sensor connection Low battery Circuit error Calibration range | |
Sample Method | Sample draw pump, flow rate 0.45 LPM 30 meter sample range | ||
Display
|
Digital LCD, auto backlite, peak bar display, auto display rotation, and customise order of gases | ||
Audible Alarm | 95 dB at 30cm | ||
Continuous Operation | 24 hours on Lithium-ion battery pack Complete recharge in 3 hours 8 hours Alkaline battery pack (3 AA size in each pack) |
||
Operating Temp. & Humidity | -20°C to +50°C, 0- 95% RH non-condensing
|
||
Dimensions | 70mm W x 201mm H x 54mm D 600g (with lithium battery pack) | ||
Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) | ||
Safety Design / Approvals
|
Explosion proof: IECEx , ATEX , TIIS , Explosion class : Ex ia IIB T4/T3 Ga -20°C ≤ Ta ≤ +50°C Ex ia IIC T4/T3 Ga -20°C ≤ Ta ≤ +50°C Others: CE Marking | ||
Standard Features
|
2 Smart sensors slots auto recognize sensor changes
Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Data logging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode |
||
Standard Accessories | • Taper nozzle Accessories
• Hand strap • LCD protect nozzle • Belt clip • Rubber boot • Li-Ion battery unit (BUL-6000) |
||
Optional Accessories | • Alkaline battery pack & charger • Filter set • IrDA cable |
||
Warranty | Two years material (including sensors) and workmanship. One year for PID sensor |
Gases & Detectable Ranges
Gases & Detectable Ranges | ||||||
Gas |
Measuring Range |
Minimum Display |
Alarm Set Points |
Accuracy (which ever is greater) | ||
Catalytic | ||||||
Hydrocarbons (CH4, std) |
0 – 100% LEL |
1% LEL |
A1: 5%LEL | ± 5% of reading or ± 2% LEL | ||
A2: 10%LEL | ||||||
Galvanic | ||||||
Oxygen (O2) |
0 – 40% Vol. |
0.1% Vol. |
A1: 19.5 Vol. |
± 0.5% O2 |
||
A2: 23.5 Vol. | ||||||
Electro Chemical | ||||||
Carbon Monoxide (CO) |
0 – 500 ppm |
1 ppm |
A1: 30 ppm |
± 5% of reading or ± 5 ppm |
||
A2: 60 ppm | ||||||
TWA: 30 ppm | ||||||
STEL: 60 ppm | ||||||
Hydrogen Sulfide (H2S) |
0 – 100 ppm |
0.5 ppm |
A1: 10 ppm |
± 5% of reading or ± 2 ppm |
||
A2: 15 ppm | ||||||
TWA: 10 ppm | ||||||
STEL: 15 ppm | ||||||
Toxics (EC Sensors) | ||||||
Ammonia (NH3) | 0 – 400 ppm | 0.5 | ppm | A1: 25 ppm |
± 10% of reading or ± 5% of full scale |
|
A2: 35 ppm | ||||||
Hydrogen Cyanide (HCN) | 0 – 15 | ppm | 0.1 ppm | A1: 5 ppm | ||
A2: 10 ppm | ||||||
Nitrogen Dioxide (NO2) | 0 – 20 | ppm |
0.05 ppm |
A1: 3 ppm | ||
A2: 5 ppm | ||||||
Sulfur Dioxide (SO2) | 0 – 99.90 ppm | A1: 2 ppm | ||||
A2: 5 ppm | ||||||
Phosphine
(PH3) |
0 – 20 | ppm* | 0.2 | ppm | A1: 0.3 ppm | |
A2: 1 ppm | ||||||
IR Sensors | ||||||
Carbon Dioxide (CO2) |
0 – 10,000 ppm |
20 ppm |
A1: 5,000 ppm |
± 5% of reading or ± 2% of full scale |
||
TWA: 5,000 ppm | ||||||
0 – 10% Vol. |
0.02% |
A1: 0.50% Vol | ||||
A2: 3.00% Vol | ||||||
STEL: 3.00% Vol | ||||||
TWA: 0.50% Vol | ||||||
Methane (CH4) | 0 – 100% LEL
0 – 100% Vol. |
Vol. 1% LEL/ 0.5% Vol |
A1: 5% LEL
* |
|||
Hydrocarbons
(HC) |
0 – 100% LEL
0 – 30% Vol. |
A2: 10% LEL
* |
||||
PID Sensors | ||||||
600 VOC 10.6 Lamp |
0 – 50,000 ppb |
1 ppb:
(< 5000 ppb) 10 ppb: (> 5,000 ppb) |
A1: 5,000 ppb |
± 10% of reading, ± 1 digit |
||
A2: 10,000 ppb | ||||||
0 – 6,000 ppm |
0.1 ppm: (< 600 ppm)
1 ppm: (> 600 ppm) |
A1: 50 ppm | ||||
A2: 100 ppm | ||||||
STEL: 100 ppm | ||||||
TWA: 50 ppm | ||||||
Benzene Specific |
0.1 – 50 ppm |
0.01 ppm
( 0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) |
No alarms | |||
300 VOC’s
10.0 Lamp |
0 – 100 ppm |
0.01 ppm
( 0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) |
A1: 5 ppm
A2: 10 ppm |
|||
High Voltage 11.7 Lamp |
0 – 1000 ppm |
0.1 ppm |
A1: 400 ppm
A2: 1,000 ppm |
Downloads:
Manual:
Specifications:
Certification:
GX-6000
GX-6000 Webinar
Calibration Station SDM-6000
Sampling Hose & Probe
Soda Lime for CO2 Zero
Charcoal for PID Zero
- Overview
-
Overview of the personal multi gas detector:
Simply put, the GX-6000 is a game changer, because this powerful hand-held personal multi gas detector instrument is capable of simultaneously monitoring up to 6 gases.
Including the standard 4 confined space gases which incorporates combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.
PID Sensor
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilising all 6 channels.
This one to six gas monitor with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard.
Choosing from the library is easy with a personalised favourites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s.
Rugged Design
The personal multi gas detector GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating.
With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives, and because of the vibration and loud audible alarms, the one to six personal monitor will easily alert users when needed.
- Specifications
-
Specifications:
Common Specifications Alarm Types Gas Alarm Man-down Trouble Low and high adjustable 1st – self reset
2nd – latchingLow flow Sensor connection Low battery Circuit error Calibration range Sample Method Sample draw pump, flow rate 0.45 LPM 30 meter sample range Display Digital LCD, auto backlite, peak bar display, auto display rotation, and customise order of gases Audible Alarm 95 dB at 30cm Continuous Operation 24 hours on Lithium-ion battery pack
Complete recharge in 3 hours
8 hours Alkaline battery pack (3 AA size in each pack)Operating Temp. & Humidity -20°C to +50°C, 0- 95% RH non-condensing Dimensions 70mm W x 201mm H x 54mm D 600g (with lithium battery pack) Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe) Safety Design / Approvals Explosion proof: IECEx , ATEX , TIIS , Explosion class : Ex ia IIB T4/T3 Ga -20°C ≤ Ta ≤ +50°C Ex ia IIC T4/T3 Ga -20°C ≤ Ta ≤ +50°C Others: CE Marking Standard Features 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases
Pump and circuit status indicators
User & station ID selection menu
Data logging (interval, alarm trend, station and user ID)
Snap logging – on demand data logging
Demand zero / Auto zero
BUMP and CAL expiration alarm
Flashlight IrDA communication
LEL sensor protection mode
Standard Accessories • Taper nozzle Accessories • Hand strap
• LCD protect nozzle
• Belt clip
• Rubber boot
• Li-Ion battery unit (BUL-6000)
Optional Accessories • Alkaline battery pack & charger
• Filter set
• IrDA cableWarranty Two years material (including sensors) and workmanship. One year for PID sensor - Detection Ranges
-
Gases & Detectable Ranges
Gases & Detectable Ranges Gas
Measuring Range
Minimum Display
Alarm Set Points
Accuracy (which ever is greater) Catalytic Hydrocarbons (CH4, std) 0 – 100% LEL
1% LEL
A1: 5%LEL ± 5% of reading or ± 2% LEL A2: 10%LEL Galvanic Oxygen (O2)
0 – 40% Vol.
0.1% Vol.
A1: 19.5 Vol. ± 0.5% O2
A2: 23.5 Vol. Electro Chemical Carbon Monoxide (CO)
0 – 500 ppm
1 ppm
A1: 30 ppm ± 5% of reading or
± 5 ppm
A2: 60 ppm TWA: 30 ppm STEL: 60 ppm Hydrogen Sulfide (H2S)
0 – 100 ppm
0.5 ppm
A1: 10 ppm ± 5% of reading or
± 2 ppm
A2: 15 ppm TWA: 10 ppm STEL: 15 ppm Toxics (EC Sensors) Ammonia (NH3) 0 – 400 ppm 0.5 ppm A1: 25 ppm ± 10% of reading or
± 5% of full scale
A2: 35 ppm Hydrogen Cyanide (HCN) 0 – 15 ppm 0.1 ppm A1: 5 ppm A2: 10 ppm Nitrogen Dioxide (NO2) 0 – 20 ppm 0.05 ppm
A1: 3 ppm A2: 5 ppm Sulfur Dioxide (SO2) 0 – 99.90 ppm A1: 2 ppm A2: 5 ppm Phosphine (PH3)
0 – 20 ppm* 0.2 ppm A1: 0.3 ppm A2: 1 ppm IR Sensors Carbon Dioxide (CO2)
0 – 10,000 ppm
20 ppm
A1: 5,000 ppm ± 5% of reading or
± 2% of full scale
TWA: 5,000 ppm 0 – 10% Vol.
0.02%
A1: 0.50% Vol A2: 3.00% Vol STEL: 3.00% Vol TWA: 0.50% Vol Methane (CH4) 0 – 100% LEL 0 – 100% Vol.
Vol. 1% LEL/
0.5% Vol
A1: 5% LEL *
Hydrocarbons (HC)
0 – 100% LEL 0 – 30% Vol.
A2: 10% LEL *
PID Sensors 600
VOC
10.6 Lamp
0 – 50,000 ppb
1 ppb: (< 5000 ppb)
10 ppb:
(> 5,000 ppb)
A1: 5,000 ppb ± 10% of reading,
± 1 digit
A2: 10,000 ppb 0 – 6,000 ppm
0.1 ppm: (< 600 ppm) 1 ppm:
(> 600 ppm)
A1: 50 ppm A2: 100 ppm STEL: 100 ppm TWA: 50 ppm Benzene Specific
0.1 – 50 ppm
0.01 ppm ( 0 ~ 10 ppm)
0.1 ppm (10 ~ 50 ppm)
No alarms 300 VOC’s 10.0 Lamp
0 – 100 ppm
0.01 ppm ( 0 ~ 10 ppm)
0.1 ppm (10 ~ 100 ppm)
A1: 5 ppm A2: 10 ppm
High Voltage
11.7 Lamp
0 – 1000 ppm
0.1 ppm
A1: 400 ppm A2: 1,000 ppm
- Downloads
-
Downloads:
Manual:
Specifications:Certification:
- Videos
-
GX-6000
GX-6000 Webinar
- Accessories
-
Calibration Station SDM-6000
Sampling Hose & Probe
Soda Lime for CO2 Zero
Charcoal for PID Zero