Features:
- Simultaneous detection of up to 6 gases.
- Sensor warranty up to 3 years.
- Explosion-proof, dust-proof and waterproof (equivalent to
- IP66/68), 1.5m drop durability.
- Equipped with Bluetooth, Easy data management via smartphone.
Application/s:
- Marine
- Industrial
- Onland
Overview of the portable multi gas detector:
A single unit suitable for all kind of marine, onshore and underground work situations. Innovative new gas detector.
SUITABLE FOR LARGE TANKS
Includes a high-power pump allowing use even for large thanks. Capable of aspirating and assessing gases from up to 45m away using the optional sampling tube.
FEATURES FOR EASE OF USE
- 16 Different language displays
- USB Type-C charging and data transfer
- Combustible gas conversion function (when new ceramic type sensor is installed)
- Alarm setpint setting function
- Confirmation beep function
- Calibration notification function
DURABILITY



BLUETOOTH EQUIPPED
Specifications of the portable multi gas detector:
Concentration display |
LCD digital (full dot) |
Detection target gas |
Combustible gas (i-C4H10 / CH4 / H2 / C2H2), oxygen (O2), toxic gas (H2S[low concentration] / CO / NH3 / CI2 / O3 / HCI / SO2 / VOCs), carbon dioxide (CO2) |
Detection method |
Pump suction type |
Suction flow rate |
Minimum 0.75 L/min (open flow rate) |
Display items |
Clock, battery level, operating status |
Display languages |
English, Cantonese, Czeh, French, German, Italian, Japanese, Korean, Mandarin, Polish, Portuguese, Russian, Slovak, Spanish, Turkish, Vietnamese |
Buzzer volume |
Approx. 95dB (mean value at 30cm from sound source) |
Gas alarm indication |
Lamp flashing, continuous modulating buzzer sounding, gas concentration readout blinking |
Gas alarm pattern |
Self-latching, auto reset |
Fault alarm/ selfdiagnosis |
Flow abnormality, system abnormality, sensor abnormality, low battery voltage, calibration failure, clock abnormality |
Fault alarm icon |
Lamp flashing, intermittent buzzer sounding, detail display |
Fault alarm pattern |
Self-latching |
Communication specifications |
USB 2.0 Type-C (for data logger/setting), Bluetooth 4.2 (Bluetooth Low Energy) |
Power source |
Dedicated Lithium-Ion battery unit (BUL-9000) or dedicated dry battery unit (AA alkaline batteries x 6) (BUD-9000) |
Continuous operating time *1 |
Lithium-Ion battery unit: approx. 25 hours Dry battery unit: approx. 12 hours (at 25 °C, no alarm, no lighting) |
Operating temperature range *2 |
Approx. 15-minute temporary use environment: -40°C to +60°C (no sudden changes) Continuous use environment: -20°C to +50°C (no sudden changes) |
Operating humidity range*2 |
Approx. 15-minute temporary use environment: 0 %RH to 90 %RH (no condensation) Continuous use environment: 10 %RH to 90 %RH (no condensation) |
Operating pressure range |
80 kPa to 120 kPa (80 kPa to 110 kPa for explosion-proof range) |
Construction |
Dustproof, waterproof construction equivalent to IP66/68*3, drop resistant to 1.5m |
Explosion-proof construction |
Intrinsically safe explosion-proof construction, flame-proof enclosures (with new ceramic type sensor) Intrinsically safe explosion-proof construction (without new ceramic type sensor) |
Explosion-proof class |
IECEx *4 ATEX*4 Japan EX Ex da ia IIC T4 Ga II 1 G Ex da ia IIC T4 Ga Ex da ia IIC T4 Ga (with new ceramic type sensor) (with new ceramic type sensor) (with new ceramic type sensor) Ex ia IIC T4 Ga II 1 G Ex ia IIC T4 Ga Ex ia IIC T4 Ga (without new ceramic type sensor) (without new ceramic type sensor) (without new ceramic type sensor) |
Certifications |
CE marking, JIS T 8201:2010 (Oxygen deficiency indicator), JIS T 8205:2018 (Hydrogen sulfide indicator/alarm) |
External dimensions |
Approx. 158 mm (W) x 85 mm (H) x 132 mm (D) (excluding projections) |
Weight *5 |
Approx 1.1 kg |
- *1 Continuous operating time: Varies depending on the sensor installed.
- *2 Operating ambient temperature/humidity range: May vary depending on the sensor installed. Refer to “Sensor Specifications”.
- *3 IPx8: No water penetration when submerged at depth of 2 m for 1 hour.
- *4 Dry battery models when using Toshiba (LR6) or Duracell (MN1500) batteries: -40°C to +40°C: T4, -40°C to +60°C: T3.
- *5 Including bettery and battery unit.


GX-9000 Portable Multi Gas Detector Downloads:
Accessories for the GX-9000 and GX-9000H
Tubes and Belts





Other accessories





Accessories for the GX-9000 and GX-9000H
Tubes

Sampling tube with float
Gas can be separated from water and detected by a waterproof filter inside the float. Ideal for locations where water is present at the detection point.
Tube length: 8m, 30m, 45m


Sampling tube with weight
The tube end is weighted to make it easier to lower. Ideal for use in narrow pipes and other confined locations.
Tube length: 30m, 45m

Batteries


Filter



Case/Holder


Management software and cable

Sensor Selection

Sensor selection examples

Product code table

- Overview
-
Overview of the portable multi gas detector:
A single unit suitable for all kind of marine, onshore and underground work situations. Innovative new gas detector.
SUITABLE FOR LARGE TANKS
Includes a high-power pump allowing use even for large thanks. Capable of aspirating and assessing gases from up to 45m away using the optional sampling tube.
FEATURES FOR EASE OF USE
- 16 Different language displays
- USB Type-C charging and data transfer
- Combustible gas conversion function (when new ceramic type sensor is installed)
- Alarm setpint setting function
- Confirmation beep function
- Calibration notification function
DURABILITY
Operating Temperature range for the GX-9000/GX-900H Protection level equivalent or the GX-9000/GX-900H Drop test for the GX-9000/GX-900H BLUETOOTH EQUIPPED
- Specifications
-
Specifications of the portable multi gas detector:
Concentration display
LCD digital (full dot)
Detection target gas
Combustible gas (i-C4H10 / CH4 / H2 / C2H2), oxygen (O2), toxic gas (H2S[low concentration] / CO / NH3 / CI2 / O3 / HCI / SO2 / VOCs), carbon dioxide (CO2)
Detection method
Pump suction type
Suction flow rate
Minimum 0.75 L/min (open flow rate)
Display items
Clock, battery level, operating status
Display languages
English, Cantonese, Czeh, French, German, Italian, Japanese, Korean, Mandarin, Polish, Portuguese, Russian, Slovak, Spanish, Turkish, Vietnamese
Buzzer volume
Approx. 95dB (mean value at 30cm from sound source)
Gas alarm indication
Lamp flashing, continuous modulating buzzer sounding, gas concentration readout blinking
Gas alarm pattern
Self-latching, auto reset
Fault alarm/ selfdiagnosis
Flow abnormality, system abnormality, sensor abnormality, low battery voltage, calibration failure, clock abnormality
Fault alarm icon
Lamp flashing, intermittent buzzer sounding, detail display
Fault alarm pattern
Self-latching
Communication
specifications
USB 2.0 Type-C (for data logger/setting), Bluetooth 4.2 (Bluetooth Low Energy)
Power source
Dedicated Lithium-Ion battery unit (BUL-9000) or dedicated dry battery unit (AA alkaline batteries x 6) (BUD-9000)
Continuous operating time *1
Lithium-Ion battery unit: approx. 25 hours
Dry battery unit: approx. 12 hours (at 25 °C, no alarm, no lighting)
Operating temperature range *2
Approx. 15-minute temporary use environment: -40°C to +60°C (no sudden changes) Continuous use environment: -20°C to +50°C (no sudden changes)
Operating humidity range*2
Approx. 15-minute temporary use environment: 0 %RH to 90 %RH (no condensation) Continuous use environment: 10 %RH to 90 %RH (no condensation)
Operating pressure range
80 kPa to 120 kPa (80 kPa to 110 kPa for explosion-proof range)
Construction
Dustproof, waterproof construction equivalent to IP66/68*3, drop resistant to 1.5m
Explosion-proof construction
Intrinsically safe explosion-proof construction, flame-proof enclosures (with new ceramic type sensor) Intrinsically safe explosion-proof construction (without new ceramic type sensor)
Explosion-proof class
IECEx *4 ATEX*4 Japan EX
Ex da ia IIC T4 Ga II 1 G Ex da ia IIC T4 Ga Ex da ia IIC T4 Ga
(with new ceramic type sensor) (with new ceramic type sensor) (with new ceramic type sensor) Ex ia IIC T4 Ga II 1 G Ex ia IIC T4 Ga Ex ia IIC T4 Ga (without new ceramic type sensor) (without new ceramic type sensor) (without new ceramic type sensor)
Certifications
CE marking, JIS T 8201:2010 (Oxygen deficiency indicator), JIS T 8205:2018 (Hydrogen sulfide indicator/alarm)
External dimensions
Approx. 158 mm (W) x 85 mm (H) x 132 mm (D) (excluding projections)
Weight *5
Approx 1.1 kg
- *1 Continuous operating time: Varies depending on the sensor installed.
- *2 Operating ambient temperature/humidity range: May vary depending on the sensor installed. Refer to “Sensor Specifications”.
- *3 IPx8: No water penetration when submerged at depth of 2 m for 1 hour.
- *4 Dry battery models when using Toshiba (LR6) or Duracell (MN1500) batteries: -40°C to +40°C: T4, -40°C to +60°C: T3.
- *5 Including bettery and battery unit.
- Sensors
-
- Downloads
-
GX-9000 Portable Multi Gas Detector Downloads:
- Videos
-
- Accessories
-
Accessories for the GX-9000 and GX-9000H
Tubes and Belts
Shoulder strap for GX-9000_GX-9000H Appearance with accessories attached for the GX-9000/GX-9000H Gas Sampling Rod for GX-9000_GX-9000H Waist belt and waist belt attachment for the GX-9000_GX-9000H Gas sampling tube for the GX-9000/GX-9000H Other accessories
AC adapter for charging for the GX-9000/GX-900H Fresh air adjustment filters for the GX-9000/GX-9000H Filter cylinder retaining belt for the shoulder strap for the GX-9000/GX-9000H Filter cylinder retaining belt for the GX-9000_GX-9000H Accessories for the GX-9000 and GX-9000H
Tubes
Sampling tube with float
Gas can be separated from water and detected by a waterproof filter inside the float. Ideal for locations where water is present at the detection point.
Tube length: 8m, 30m, 45m
Sampling tube with weight
The tube end is weighted to make it easier to lower. Ideal for use in narrow pipes and other confined locations.
Tube length: 30m, 45m
Batteries
Dry battery unit for the GX-9000_GX-9000H Lithium-ion battery unit_AC adaptor for the GX-9000_GX-9000H Filter
Water trap for the GX-9000/GX-9000H Absorbent cotton filter/Connecting tube for the GX-9000/GX-9000H Diluter for the GX-9000_GX-9000H Case/Holder
Leather Case for the GX-9000/GX-9000H Aluminium storage case for the GX-9000/GX-9000H Management software and cable
Software for gas detection instruments - Sensor Selection
-
Sensor Selection
Sensor selection examples
Product code table