Single Toxic Gas Monitor – SC-8000

Features:

  • Real-time detection with ppm range
  • Large simultaneous display with auto back lighting
  • Strong sample drawing capability
  • Loud alarm buzzer with 95dB
  • 3 bright LED alarm windows
  • IECEx Pending
  • Water and dust resistant IP67
  • Lithium-ion rechargeable battery
  • Compact and light weight
  • Datalogging standard

Application/s:

  • Semi conductor / LED / Solar Cell plants
  • Petrochemical / Chemical Plants
  • Refineries
  • Gas plant / Gas supplier services
  • Chemical tanker
  • Confined space
  • Utilities
  • Monitoring toxic gas in hazardous zone
  • Leak check at maintenance work

Overview:

The IECEx Certified Single Toxic Gas Monitor, the SC-8000, has the ability to detect some of the most common toxic gases; Silane (SiH4), Phosphine (PH3), Arsine (AsH3), Ammonia (NH3), Hydrogen Chloride (HCl), Chlorine (Cl2) and Hydrogen Fluoride (HF), and many others. With its large LCD display the readings combined with the IECEx ensures this device is ideal for some of the most dangerous applications. The fact that a user is able to view the instrument when wearing a Hazmat suit shows how adaptable this device is for even the harshest industry applications.  For loud environments the unit is equipped with a 95dB alarm together with three bright LED lamps, making alarm conditions both audible and visible in any situation.

The SC-8000 IECEx Certified Single Toxic Gas Monitor sets the new industry standard for rugged, reliable portable gas detection. Its tough, water proof design utilises features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications. The SC-8000 IECEx Certified Single Toxic Gas Monitor model has a powerful in-built suction pump.

The large, LCD display, shows a digital value of the component gas concentration. In loud environments the highly bright LED lamps are arranged in three directions making the unit visible from all angles.

Some of the most common toxic gases that the SC-8000 detects are Silane (SiH4), Phosphine (PH3), Arsine (AsH3), Ammonia (NH3), Hydrogen Chloride (HCl), Chlorine (Cl2) and Hydrogen Fluoride (HF) and many others.

Specifications:

Target Gas
Detection Range
Alarm Point
 
Please refer to gases detected
Detection Principle

 

Electrochemical

 

Types of Alarm

 

Gas Alarm: Latching, 2 alarms Failure Alarm: Flow failure, sensor failure, battery failure, circuit failure, calibration failure, setting current failure .

 

Display of Alarm

 

Lamp: High Definition LED Lights Flash Buzzer: Gas Alarm—Buzzer sounds alternating between low and high pitch Failure Alarm—Buzzer sound is continuous Display: Gas Alarm— Gas Concentration on the display flashes. Failure Alarm—Alarm message on the display flashes.

 

Alarm Sound

 

More than 95dB (A) at 30 cm

 

Sampling Method

 

Sample draw, approximately 0.5L / minute

 

Display

 

Digital LCD with auto backlight Digital display (7 Segments) and digital bar graph (25 segments)

 

Power Source

 

Lithium-ion battery: Standard 3 hours for full charge AA Alkaline battery (3 pieces): Optional

 

Continuous Operation

 

Lithium-ion battery: More than 25 hours AA Alkaline battery: More than 18 hours

 

Operating Temp & Humidity

 

-10°C ~ to +40°C, Humidity: 20~88% RH,
non-condensing
Dimensions & Weight

 

Approx 15cm x 8cm x 16cm (L x W x H),
approx 1.1kg
Ingress Proof Rating

 

Equivalent to IP67

 

Explosion proof

 

Intrinsically safe Exia II CT4

 

Approvals

 

IECEx, ATEX

 

Standard Accessories

 

Neck Shoulder Strap, Gas Sampling Hose (1m), Instruction Manual, Gas Sampling Probe, AC Powered Charger, Lithium-ion battery unit

 

Additional Features

 

Self Diagnosis Function
Zero / Span Adjustment (Demand zero / Auto zero selectable)
Indication to show energising (pilot indicator and pump driving indicator)
Bump test function IrDA Communication, Data logger (Interval, Alarm Trend, Station ID Control)
Peak Value / Average Value Display, Buzzer Selector Switch (2 steps, high / low)
Optional Accessories

 

Dry Battery Unit (BUD-8000)
Sampling Probe Holder on the neck / shoulder strap
Data logging Software
Carrying Box (Aluminium)
Waist Strap
Warranty

 

2 year material and workmanship

 

Gases Detected:

Detectable Gas

Chemical

Formula

Measuring

Range (ppm)

Increments (ppm)

Preset Alarm (ppm)

Ammonia

NH3

0~75.00 0.50 1st

2nd

Arsine

AsH3

0~0.20 0.001 25.0

50.0

Bromine

Br2

0~1.00 0.01 0.050

0.100

Carbon Monoxide

CO

0~75.00 0.50 0.30

0.60

Chlorine

Cl2

0~1.50 0.01 30.0

60.0

Chorine Trifluoride

ClF3

0~1.00 0.01 0.50

1.00

Diborane

B2H6

0~0.300 0.002 0.30

0.60

Fluorine

F2

0~3.00 0.02 0.100

0.200

Germane

GeH4

0~0.800 0.005 1.00

2.00

Hydrogen Bromine

HBr

0~6.00 0.05 0.200

0.400

Hydrogen Chloride

HCl

0~6.00 0.05 2.00

4.00

Hydrogen Cyanide

HCN

0~15.00 0.10 2.00

4.00

Hydrogen Fluoride

HF

0~9.00 0.02 4.00

10.00

Hydrogen Iodide

HI

0~5.00 0.05 1.00

2.00

Hydrogen Selenide

H2Se

0~0.200 0.001 1.50

3.00

Hydrogen Sulphide

H2S

0~30.00 0.20 0.050

0.100

Nitrogen Dioxide

NO2

0~15.00 0.10 10.00

15.0

Nitric Oxide

NO

0~100 1 5.00

10.0

Ozone

O3

0~1.00 0.01 25

50

Phosphine

PH3

0~1.00 0.01 0.30

0.60

Phosphorous Trifluoride

PF3

0~10.00 0.10 0.30

0.60

Silane

SiH4 0~15.00 0.10 2.00

4.00

Sulphur Dioxide

SO2

0~6.00 0.05 5.00

10.00

Ammonia

NH3

0~75.00 0.50 2.00

4.00

Downloads:

 

Specifications

Videos:

SC-8000 H202 Calibration

Overview

Overview:

The IECEx Certified Single Toxic Gas Monitor, the SC-8000, has the ability to detect some of the most common toxic gases; Silane (SiH4), Phosphine (PH3), Arsine (AsH3), Ammonia (NH3), Hydrogen Chloride (HCl), Chlorine (Cl2) and Hydrogen Fluoride (HF), and many others. With its large LCD display the readings combined with the IECEx ensures this device is ideal for some of the most dangerous applications. The fact that a user is able to view the instrument when wearing a Hazmat suit shows how adaptable this device is for even the harshest industry applications.  For loud environments the unit is equipped with a 95dB alarm together with three bright LED lamps, making alarm conditions both audible and visible in any situation.

The SC-8000 IECEx Certified Single Toxic Gas Monitor sets the new industry standard for rugged, reliable portable gas detection. Its tough, water proof design utilises features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications. The SC-8000 IECEx Certified Single Toxic Gas Monitor model has a powerful in-built suction pump.

The large, LCD display, shows a digital value of the component gas concentration. In loud environments the highly bright LED lamps are arranged in three directions making the unit visible from all angles.

Some of the most common toxic gases that the SC-8000 detects are Silane (SiH4), Phosphine (PH3), Arsine (AsH3), Ammonia (NH3), Hydrogen Chloride (HCl), Chlorine (Cl2) and Hydrogen Fluoride (HF) and many others.

Specifications

Specifications:

Target Gas
Detection Range
Alarm Point
 
Please refer to gases detected
Detection Principle

 

Electrochemical

 

Types of Alarm

 

Gas Alarm: Latching, 2 alarms Failure Alarm: Flow failure, sensor failure, battery failure, circuit failure, calibration failure, setting current failure .

 

Display of Alarm

 

Lamp: High Definition LED Lights Flash Buzzer: Gas Alarm—Buzzer sounds alternating between low and high pitch Failure Alarm—Buzzer sound is continuous Display: Gas Alarm— Gas Concentration on the display flashes. Failure Alarm—Alarm message on the display flashes.

 

Alarm Sound

 

More than 95dB (A) at 30 cm

 

Sampling Method

 

Sample draw, approximately 0.5L / minute

 

Display

 

Digital LCD with auto backlight Digital display (7 Segments) and digital bar graph (25 segments)

 

Power Source

 

Lithium-ion battery: Standard 3 hours for full charge AA Alkaline battery (3 pieces): Optional

 

Continuous Operation

 

Lithium-ion battery: More than 25 hours AA Alkaline battery: More than 18 hours

 

Operating Temp & Humidity

 

-10°C ~ to +40°C, Humidity: 20~88% RH,
non-condensing
Dimensions & Weight

 

Approx 15cm x 8cm x 16cm (L x W x H),
approx 1.1kg
Ingress Proof Rating

 

Equivalent to IP67

 

Explosion proof

 

Intrinsically safe Exia II CT4

 

Approvals

 

IECEx, ATEX

 

Standard Accessories

 

Neck Shoulder Strap, Gas Sampling Hose (1m), Instruction Manual, Gas Sampling Probe, AC Powered Charger, Lithium-ion battery unit

 

Additional Features

 

Self Diagnosis Function
Zero / Span Adjustment (Demand zero / Auto zero selectable)
Indication to show energising (pilot indicator and pump driving indicator)
Bump test function IrDA Communication, Data logger (Interval, Alarm Trend, Station ID Control)
Peak Value / Average Value Display, Buzzer Selector Switch (2 steps, high / low)
Optional Accessories

 

Dry Battery Unit (BUD-8000)
Sampling Probe Holder on the neck / shoulder strap
Data logging Software
Carrying Box (Aluminium)
Waist Strap
Warranty

 

2 year material and workmanship

 

Gases Detected

Gases Detected:

Detectable Gas

Chemical

Formula

Measuring

Range (ppm)

Increments (ppm)

Preset Alarm (ppm)

Ammonia

NH3

0~75.00 0.50 1st

2nd

Arsine

AsH3

0~0.20 0.001 25.0

50.0

Bromine

Br2

0~1.00 0.01 0.050

0.100

Carbon Monoxide

CO

0~75.00 0.50 0.30

0.60

Chlorine

Cl2

0~1.50 0.01 30.0

60.0

Chorine Trifluoride

ClF3

0~1.00 0.01 0.50

1.00

Diborane

B2H6

0~0.300 0.002 0.30

0.60

Fluorine

F2

0~3.00 0.02 0.100

0.200

Germane

GeH4

0~0.800 0.005 1.00

2.00

Hydrogen Bromine

HBr

0~6.00 0.05 0.200

0.400

Hydrogen Chloride

HCl

0~6.00 0.05 2.00

4.00

Hydrogen Cyanide

HCN

0~15.00 0.10 2.00

4.00

Hydrogen Fluoride

HF

0~9.00 0.02 4.00

10.00

Hydrogen Iodide

HI

0~5.00 0.05 1.00

2.00

Hydrogen Selenide

H2Se

0~0.200 0.001 1.50

3.00

Hydrogen Sulphide

H2S

0~30.00 0.20 0.050

0.100

Nitrogen Dioxide

NO2

0~15.00 0.10 10.00

15.0

Nitric Oxide

NO

0~100 1 5.00

10.0

Ozone

O3

0~1.00 0.01 25

50

Phosphine

PH3

0~1.00 0.01 0.30

0.60

Phosphorous Trifluoride

PF3

0~10.00 0.10 0.30

0.60

Silane

SiH4 0~15.00 0.10 2.00

4.00

Sulphur Dioxide

SO2

0~6.00 0.05 5.00

10.00

Ammonia

NH3

0~75.00 0.50 2.00

4.00

Downloads

Downloads:

 

Specifications

Videos

Videos:

SC-8000 H202 Calibration