Bump/Calibration Station – SDM-3R

Features:

  • Stand-alone station (no PC required)
  • Compatible with both GX-3R and GX-3R Pro
  • Automatically charge, bump test, and/or calibrate
  • Auto on/off of gas detector
  • 3 separate gas inputs
  • One set of calibration equipment serves up to 10 SDM-3R’s
  • Save Bump Test and Calibration records to a USB jump drive, computer, or network location.
  • Includes PC software for viewing/archiving bump test, calibration records, and event date

Application/s:

  • Confined spaces
  • Hazardous material
  • Refineries / petrochemical
  • Personal monitoring
  • Utilities
  • Oil and gas
  • Water / wastewater plants
  • Fire services
  • Pharmaceuticals
  • Construction

Overview:

Stand Alone Station
The SDM-3R is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi-Module System
Automate how you manage and service GX-3R (Pro) instruments by connecting the SDM-3R Calibration Station to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, archive data, or charge up to ten instruments. Also, download the datalogging history from each instrument into one easy to manage location. SDM-3R stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.

Specifications:

Input Power AC Adapter with 100 – 240 VAC, 47-63 Hz, 0.4A input and 5.99 VDC, 2A output provided as standard.
Environmental Conditions For Indoor Use Only

0° C to 40° C, below 95% Relative Humidity, Non-Condensing

Applicable Instruments GX-3R and GX-3R Pro
Maximum Number of Records Saved Stand Alone: 200 calibrations, or 214 bump test, or 469 alarm check records
PC program Controlled: Unlimited records
5 Ports 3 Calibration gas, 1 fresh air and 1 exhaust
Standard Accessories
  • AC Adapter
  • USB Flash Drive
  • Inlet Air Filter
  • 10 Foot Long Exhaust Tube
  • One 3 Foot Long Tube for GAS Fitting
  • USB Cable, Type A to Type B

Downloads:

Specifications:

Overview

Overview:

Stand Alone Station
The SDM-3R is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi-Module System
Automate how you manage and service GX-3R (Pro) instruments by connecting the SDM-3R Calibration Station to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, archive data, or charge up to ten instruments. Also, download the datalogging history from each instrument into one easy to manage location. SDM-3R stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.

Specifications

Specifications:

Input Power AC Adapter with 100 – 240 VAC, 47-63 Hz, 0.4A input and 5.99 VDC, 2A output provided as standard.
Environmental Conditions For Indoor Use Only

0° C to 40° C, below 95% Relative Humidity, Non-Condensing

Applicable Instruments GX-3R and GX-3R Pro
Maximum Number of Records Saved Stand Alone: 200 calibrations, or 214 bump test, or 469 alarm check records
PC program Controlled: Unlimited records
5 Ports 3 Calibration gas, 1 fresh air and 1 exhaust
Standard Accessories
  • AC Adapter
  • USB Flash Drive
  • Inlet Air Filter
  • 10 Foot Long Exhaust Tube
  • One 3 Foot Long Tube for GAS Fitting
  • USB Cable, Type A to Type B
Downloads

Downloads:

Specifications:

Enquire Now

    Name*

    Phone*

    Location

    Email*

    How did you hear about us?*

    Message