Smart Transmitter Detector – SD-1

SD-1 Smart Transmitter Detector

Features:

  • Wide range of detectable gases
    • % LEL Combustibles, catalytic
    •  % LEL Combustibles, IR
    •  H2S, CO, & O2
    •  PPM for acrylonitrile, hydrogen, ethylene oxide, methyl pyrolidone, methylene chloride, and many others
  • Sensor types include
    • Catalytic, Galvanic Cell, MOS, IR, & Electrochemical
  • Direct digital display of gas readings
  • HART Communication protocol or 4-20 linear output
  • Available with SIL2 approval (IR, EC, OX versions)
  • Easy maintenance using a magnetic key
  • Self-diagnosis by microprocessor
  • Low power operation (Maximum: 3W)
  • Explosion proof: ATEX, IECEx, ExdIICT5

Application/s:

  • LNG Terminal
  • Petrochemical/Chemical plants
  • Power plant
  • Utilities
  • Iron and steel works

Overview:

Our SD-1 line of smart transmitters feature state-of-the-art gas detectors with durable flameproof enclosure, maximum safety, especially in hydrogen/ acethylene atmospheres. A simple magnetic control key is placed over clear marked positions on the surface plate to test and adjust the instrument without opening the transmitter in situations with danger of explosion. This “single-man-calibration” is already in use and applicable with other Control Equipment gas detectors for easy maintenance.

Specifications:

 

Model

 

SD-1GP

 

SD-1RI

 

SD-1GH

 

SD-1EC

 

SD-1OX

Detection principle Catalytic Infrared Semiconductor Electrochemical Galvanic Cell
Measuring gas Variety of hydrocarbons  

 

See datasheet

CO/H2S Oxygen
 

Measuring range

 

0 -100% LEL

CO: 0-75ppm H2S: 0-30ppm  

0 -25 vol%

Alarm setting 2 programmable alarm set points/increasing/decreasing/latching/ self resetting/on delays/off delays/energised/energised
Alarm contacts Normally open or normally closed
Sampling method Diffusion (Flow adapter and air aspiration available)
Display 4 digit Digital LED
Output 4-20 mA or HART (optional without 4-20 mA)
Relay 1 Relay with 4-20 mA versions or No relay with HART versions
Contact capacity 30 VDC 0.5A or 120 VAC 0.5A (load resistance)
Fail alert Self diagnosis Circuit failure / Sensor failure
Fail alert display Fail lamp (Yellow)
Power source 24VDC (17VDC ~ 26.4VDC)
Operating Temperature & humidity -20 ~ + 60°C / below 95% RH (non condensing), (SD-1EC Below 80% RH)
Dimension & Weight 148(W) x 161(H) x 88(D) mm, Approx. 2.0kg
Approvals

**Applied to SD-1GP for H2, CH4, i-C4H10, C3H8

Exd II CT5,ATEX **

IECEx EN60079-29-1

CML 15ATEX1034 IECEX, SIL2 Exd II CT5,ATEX, IECEx DEKRA 13ATEX0035 IECEx DEK 13.0024X, SIL2

Downloads:

Specifications:

Overview

Overview:

Our SD-1 line of smart transmitters feature state-of-the-art gas detectors with durable flameproof enclosure, maximum safety, especially in hydrogen/ acethylene atmospheres. A simple magnetic control key is placed over clear marked positions on the surface plate to test and adjust the instrument without opening the transmitter in situations with danger of explosion. This “single-man-calibration” is already in use and applicable with other Control Equipment gas detectors for easy maintenance.

Specifications

Specifications:

 

Model

 

SD-1GP

 

SD-1RI

 

SD-1GH

 

SD-1EC

 

SD-1OX

Detection principle Catalytic Infrared Semiconductor Electrochemical Galvanic Cell
Measuring gas Variety of hydrocarbons  

 

See datasheet

CO/H2S Oxygen
 

Measuring range

 

0 -100% LEL

CO: 0-75ppm H2S: 0-30ppm  

0 -25 vol%

Alarm setting 2 programmable alarm set points/increasing/decreasing/latching/ self resetting/on delays/off delays/energised/energised
Alarm contacts Normally open or normally closed
Sampling method Diffusion (Flow adapter and air aspiration available)
Display 4 digit Digital LED
Output 4-20 mA or HART (optional without 4-20 mA)
Relay 1 Relay with 4-20 mA versions or No relay with HART versions
Contact capacity 30 VDC 0.5A or 120 VAC 0.5A (load resistance)
Fail alert Self diagnosis Circuit failure / Sensor failure
Fail alert display Fail lamp (Yellow)
Power source 24VDC (17VDC ~ 26.4VDC)
Operating Temperature & humidity -20 ~ + 60°C / below 95% RH (non condensing), (SD-1EC Below 80% RH)
Dimension & Weight 148(W) x 161(H) x 88(D) mm, Approx. 2.0kg
Approvals

**Applied to SD-1GP for H2, CH4, i-C4H10, C3H8

Exd II CT5,ATEX **

IECEx EN60079-29-1

CML 15ATEX1034 IECEX, SIL2 Exd II CT5,ATEX, IECEx DEKRA 13ATEX0035 IECEx DEK 13.0024X, SIL2