GX- 6100 Portable Benzene Gas Monitor

 Features

  • Benzene-specific measurement
  • 0.01 – 50 ppm with 10.0 eV PID lamp and pre-filter tube
  • Benzene select mode takes timed samples using a pre-filter tube
  • Long break through times for benzene filter tubes
  • 10.0 eV Selective PID sensor, 0 – 100 ppm VOC range
  • Library of over 300 VOC’s including BTEX
  • Dual channel PIDs utilising both 10.0 & 10.6 PID sensors
  • 2 smart sensor slots auto-recognise PID, IR, and toxic sensors
  • Dust & Water resistant IP-67 design
  • Interchangeable battery packs Li-ion / alkaline
  • Operates up to 14 hours on Li-ion battery, fully recharges in 3 hours
  • Humidity resistant
  • Easily switched VOC target gas – favourite list of 30 VOC’s

Applications

  • Personal monitoring
  • Petroleum / Oil refining

  • Chemical manufacturing

  • Rubber & Tire manufacturing

  • Coke & Coal manufacturing

  • Fuel Storage & Tank Farms

  • Hazmat response teams

GX-6100 Portable Benzene Gas Detector Overview

The GX-6100 Benzene personal detector is a lightweight and convenient-to-carry monitor, weighing in at only 600 grams, including the rubber boot. Simply put, the GX-6100 is a game changer with Benzene-specific measuring mode..

With a library of over 300 VOC’s and the addition of the highly selective 10.0 eV PID sensor, including BTEX (benzene, toluene, ethylbenzene, and xylene) family of VOC’s up to 100 ppm. By using filtering tubes and the tube holder, the GX-6100 can monitor specifically for Benzene at a range of 0 – 50ppm (with resolutions as small as 0.01) by filtering out all other VOC’s. The filter tube holder features a unique breakaway design to prevent damage in the event of accidental impact. The filter tube also has a safe and convenient glass breaker for the filter tube tips.

The GX-6100 is the only PID instrument in the market with the ability to utilise two PID sensors in one instrument. When using the broad range 10.6eV PID for preliminary investigation, it is possible to switch to benzene mode for a highly accurate measurement.

The GX-6100 features a rugged design designed for the most demanding environments. It is equipped with a removable impact-resistant rubber boot and a dust and water-resistant enclosure with an IP-67 rating. With five bright LED lights on three sides of the instrument, alarms are easily visible from a variety of perspectives. With vibration and a loud audible alarm, GX-6100 will easily alert users when needed.

 

GX-6100 Gas Monitor Specifications

Alarm Types Gas alarm Man-down Trouble
Low and high adjustable 1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration failure

Sample Method Sample draw pump, flow rate 0.45 LPM, 100 foot sample range
Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Communication Bluetooth, IrDA
Audible Alarm 95 dB at 1 ft.
Languages English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish
Continuous
Operation
28 hours on Lithium-ion battery pack. Complete recharge in 6 hours.

8 hours Alkaline battery pack (3 AA size in each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions 2.6” W x 7.9” H x 2.2” D (H200 x W68 x D56 mm)
17.6 ounce (500g) with lithium battery pack16 ounces with alkaline batteries (450g)
Case Material Dust and water resistant with IP-67 approval
(exclude sample hose and probe)
Safety Design /

Approvals

Explosion proof: IECEx , ATEX , TIIS , cCSAus (pending)

Explosion class :Ex ia IIC T4 Ga Others: CE Marking

Standard
Features
2 Smart sensors slots auto recognize sensor changes

Panic alarm and man down alarm

Library of over 600 VOC’s

User defined VOC list. Up to 30 frequently used

Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Datalogging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight

LEL sensor protection mode

Standard
Accessories
• Rubber boot • Belt clip
• Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose• Benzene pre-filter tubes and holder (benzene versions)
Optional
Accessories
• SDM-6100 calibration station

• Bundles with instrument carrying case and accessories

• Flexible probes

• Up to 100 foot sample hoses

• Filter set

• IrDA cable

Warranty

Three years material (including  R sensors) and
workmanship. 2 years for IR sensors and ESS (except Cl2), One year for TE, Cl2 and PID sensors (Two months for 11.7 eV lamp)

GX-6100 Gas Monitor Gases & Detectable Ranges

Gas Detection Range Reading Increment Alarm Set Points Accuracy
PID Sensors
10.6 Lamp 600 VOC’s 0 – 40,000 ppb 1 ppb: (< 5000 ppb)

10 ppb: (> 5,000 ppb)

A1: 5,000 ppb

A2: 10,000 ppb

A3: 10,000 ppb

± 10% of reading,

± 1 digit

0 – 4,000 ppm 0.1 ppm: (< 600 ppm)

1 ppm: (> 600 ppm)

A1: 400 ppm

A2: 1,000 ppm

A3: 1,000 ppm

10.0 Lamp Benzene Specific 0 – 50 ppm 0.01 ppm (0 ~ 10 ppm)

0.1 ppm (10 ~ 50 ppm)

No Alarms
300 VOC’s 0 – 100 ppm 0.01 ppm (0 ~ 10 ppm)

0.1 ppm (10 ~ 100 ppm)

A1: 5 ppm

A2: 10 ppm

A3: 10 ppm

11.7 High Voltage Lamp 0 – 1,000 ppm 0.1 ppm (0-100 ppm)

1 ppm (100-1,000 ppm)

A1: 400 ppm

A2: 1,000 ppm

A3: 1,000 ppm

Electro Chemical R Sensor
Oxygen (O2) 0 – 40.0% Vol. 0.1% Vol. A1: 19.5 Vol.

A2: 18 Vol.

A3: 23.5 Vol.

± 0.5% O2
Carbon Monoxide (CO) 0 – 2,000 ppm 1 ppm A1: 25 ppm

A2: 50 ppm

A3: 1,200 ppm

TWA 25 ppm

STEL 200 ppm

± 5% of

reading or

± 5 ppm

Hydrogen Sulfide (H2S) 0 – 200.0 ppm 0.5 ppm A1: 5.0 ppm

A2: 30.0 ppm

A3: 100.0 ppm

TWA 1.0 ppm

STEL 5.0 ppm

± 5% of

reading or

± 2 ppm

Toxics (EC Sensors)
Ammonia (NH3) 0 – 400.0 ppm 0.5 ppm A1: 25 ppm

A2: 50 ppm

A3: 50 ppm

± 10% of

reading or ± 5% of full scale

Chlorine

(Cl2)

0 – 10.00 ppm 0.05 ppm A1: 0.5 ppm

A2: 1.0 ppm

A3: 1.0 ppm

Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm A1: 5 ppm

A2: 10 ppm

A3: 10 ppm

Nitrogen Dioxide (NO2) 0 – 20.00 ppm 0.05 ppm A1: 3 ppm

A2: 6 ppm

A3: 6 ppm

Phosphine (PH3) 0 – 20.00 ppm 0.01 ppm A1: 0.30 ppm

A2: 1.00 ppm

A3: 1.00 ppm

Sulfur Dioxide (SO2) 0 – 99.90 ppm 0.05 ppm A1: 2 ppm

A2: 5 ppm

A3: 5 ppm

Smart Sensors

NDIR Smart Sensors
Carbon Dioxide (CO2) NDIR 0 – 10,000 ppm 20 ppm A1: 5,000 ppm

TWA 5,000 ppm

± 5% of
reading or ± 2% of full scale
0 – 10.00% Vol. 0.02% A1: 0.50% Vol

A2: 3.00% Vol

A3: 3.00% Vol

STEL 3.00% Vol

TWA 0.50% Vol

Methane NDIR 0 – 100% LEL

0 – 100% Vol.

1% LEL/
0.5% Vol
A1: 10% LEL

A2: 50% LEL

A3: 50% LEL

Isobutane NDIR 0 – 100% LEL
0 – 30% Vol.
Smart Sensor (hot-wire semiconductor type)
Methane 0 – 5,000 ppm 10 ppm N/A
Isobutane 0 – 2,000 ppm
R Sensor (new ceramic type)
Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL

A2: 25%LEL

A3: 50%LEL

± 5% of
reading or ± 2% LEL
TC Sensor (thermal conductivity)
Methane CH4 0 – 100 vol% 1% vol% N/A

GX-6100 Accessories
Overview

GX-6100 Portable Benzene Gas Detector Overview

The GX-6100 Benzene personal detector is a lightweight and convenient-to-carry monitor, weighing in at only 600 grams, including the rubber boot. Simply put, the GX-6100 is a game changer with Benzene-specific measuring mode..

With a library of over 300 VOC’s and the addition of the highly selective 10.0 eV PID sensor, including BTEX (benzene, toluene, ethylbenzene, and xylene) family of VOC’s up to 100 ppm. By using filtering tubes and the tube holder, the GX-6100 can monitor specifically for Benzene at a range of 0 – 50ppm (with resolutions as small as 0.01) by filtering out all other VOC’s. The filter tube holder features a unique breakaway design to prevent damage in the event of accidental impact. The filter tube also has a safe and convenient glass breaker for the filter tube tips.

The GX-6100 is the only PID instrument in the market with the ability to utilise two PID sensors in one instrument. When using the broad range 10.6eV PID for preliminary investigation, it is possible to switch to benzene mode for a highly accurate measurement.

The GX-6100 features a rugged design designed for the most demanding environments. It is equipped with a removable impact-resistant rubber boot and a dust and water-resistant enclosure with an IP-67 rating. With five bright LED lights on three sides of the instrument, alarms are easily visible from a variety of perspectives. With vibration and a loud audible alarm, GX-6100 will easily alert users when needed.

 

Specifications

GX-6100 Gas Monitor Specifications

Alarm Types Gas alarm Man-down Trouble
Low and high adjustable 1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration failure

Sample Method Sample draw pump, flow rate 0.45 LPM, 100 foot sample range
Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Communication Bluetooth, IrDA
Audible Alarm 95 dB at 1 ft.
Languages English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish
Continuous
Operation
28 hours on Lithium-ion battery pack. Complete recharge in 6 hours.

8 hours Alkaline battery pack (3 AA size in each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions 2.6” W x 7.9” H x 2.2” D (H200 x W68 x D56 mm)
17.6 ounce (500g) with lithium battery pack16 ounces with alkaline batteries (450g)
Case Material Dust and water resistant with IP-67 approval
(exclude sample hose and probe)
Safety Design /

Approvals

Explosion proof: IECEx , ATEX , TIIS , cCSAus (pending)

Explosion class :Ex ia IIC T4 Ga Others: CE Marking

Standard
Features
2 Smart sensors slots auto recognize sensor changes

Panic alarm and man down alarm

Library of over 600 VOC’s

User defined VOC list. Up to 30 frequently used

Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Datalogging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight

LEL sensor protection mode

Standard
Accessories
• Rubber boot • Belt clip
• Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose• Benzene pre-filter tubes and holder (benzene versions)
Optional
Accessories
• SDM-6100 calibration station

• Bundles with instrument carrying case and accessories

• Flexible probes

• Up to 100 foot sample hoses

• Filter set

• IrDA cable

Warranty

Three years material (including  R sensors) and
workmanship. 2 years for IR sensors and ESS (except Cl2), One year for TE, Cl2 and PID sensors (Two months for 11.7 eV lamp)

Detection Ranges

GX-6100 Gas Monitor Gases & Detectable Ranges

Gas Detection Range Reading Increment Alarm Set Points Accuracy
PID Sensors
10.6 Lamp 600 VOC’s 0 – 40,000 ppb 1 ppb: (< 5000 ppb)

10 ppb: (> 5,000 ppb)

A1: 5,000 ppb

A2: 10,000 ppb

A3: 10,000 ppb

± 10% of reading,

± 1 digit

0 – 4,000 ppm 0.1 ppm: (< 600 ppm)

1 ppm: (> 600 ppm)

A1: 400 ppm

A2: 1,000 ppm

A3: 1,000 ppm

10.0 Lamp Benzene Specific 0 – 50 ppm 0.01 ppm (0 ~ 10 ppm)

0.1 ppm (10 ~ 50 ppm)

No Alarms
300 VOC’s 0 – 100 ppm 0.01 ppm (0 ~ 10 ppm)

0.1 ppm (10 ~ 100 ppm)

A1: 5 ppm

A2: 10 ppm

A3: 10 ppm

11.7 High Voltage Lamp 0 – 1,000 ppm 0.1 ppm (0-100 ppm)

1 ppm (100-1,000 ppm)

A1: 400 ppm

A2: 1,000 ppm

A3: 1,000 ppm

Electro Chemical R Sensor
Oxygen (O2) 0 – 40.0% Vol. 0.1% Vol. A1: 19.5 Vol.

A2: 18 Vol.

A3: 23.5 Vol.

± 0.5% O2
Carbon Monoxide (CO) 0 – 2,000 ppm 1 ppm A1: 25 ppm

A2: 50 ppm

A3: 1,200 ppm

TWA 25 ppm

STEL 200 ppm

± 5% of

reading or

± 5 ppm

Hydrogen Sulfide (H2S) 0 – 200.0 ppm 0.5 ppm A1: 5.0 ppm

A2: 30.0 ppm

A3: 100.0 ppm

TWA 1.0 ppm

STEL 5.0 ppm

± 5% of

reading or

± 2 ppm

Toxics (EC Sensors)
Ammonia (NH3) 0 – 400.0 ppm 0.5 ppm A1: 25 ppm

A2: 50 ppm

A3: 50 ppm

± 10% of

reading or ± 5% of full scale

Chlorine

(Cl2)

0 – 10.00 ppm 0.05 ppm A1: 0.5 ppm

A2: 1.0 ppm

A3: 1.0 ppm

Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm A1: 5 ppm

A2: 10 ppm

A3: 10 ppm

Nitrogen Dioxide (NO2) 0 – 20.00 ppm 0.05 ppm A1: 3 ppm

A2: 6 ppm

A3: 6 ppm

Phosphine (PH3) 0 – 20.00 ppm 0.01 ppm A1: 0.30 ppm

A2: 1.00 ppm

A3: 1.00 ppm

Sulfur Dioxide (SO2) 0 – 99.90 ppm 0.05 ppm A1: 2 ppm

A2: 5 ppm

A3: 5 ppm

Smart Sensors

NDIR Smart Sensors
Carbon Dioxide (CO2) NDIR 0 – 10,000 ppm 20 ppm A1: 5,000 ppm

TWA 5,000 ppm

± 5% of
reading or ± 2% of full scale
0 – 10.00% Vol. 0.02% A1: 0.50% Vol

A2: 3.00% Vol

A3: 3.00% Vol

STEL 3.00% Vol

TWA 0.50% Vol

Methane NDIR 0 – 100% LEL

0 – 100% Vol.

1% LEL/
0.5% Vol
A1: 10% LEL

A2: 50% LEL

A3: 50% LEL

Isobutane NDIR 0 – 100% LEL
0 – 30% Vol.
Smart Sensor (hot-wire semiconductor type)
Methane 0 – 5,000 ppm 10 ppm N/A
Isobutane 0 – 2,000 ppm
R Sensor (new ceramic type)
Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL

A2: 25%LEL

A3: 50%LEL

± 5% of
reading or ± 2% LEL
TC Sensor (thermal conductivity)
Methane CH4 0 – 100 vol% 1% vol% N/A

Downloads
Accessories
GX-6100 Accessories

Enquire Now