Beacon 3200 Thirty-Two Channel Wall Mount Controller

Beacon 3200 Channel Gas Detection Controller

Features

  • Simultaneously control up to 32 gas monitoring channels
  • 8 sensor re relay module slots for flexible configurations:
    – 4 Sensors per module card
    – 8 Relays per module card
    – Up to 3 programmable alarm levels per channel
  • 3 common alarm relays and 1 fail relay as standard
  • 7” Color LCD Touchscreen display of all 32 channels
  • Accepts LEL / O2 / CO2 / toxic direct connect sensors
  • Accepts any 4-20 mA transmitter, 2 or 3 wire
  • 4-20 mA, RS-485, and Modbus TCP/IP outputs standard
  • 115 / 220 VAC or 24 VDC operation
  • Audible alarm with silence feature
  • RFI / EMI resistant
  • Alarm reset switch
  • Weather and corrosion resistant NEMA 4X enclosure

Applications

  • Petrochemical plants
  • Water & wastewater treatment plants
  • Gas, telephone, & electric utilities
  • Any industrial plant
  • Refineries
  • Pulp & paper mills
  • Parking garages
  • Steel

Beacon 3200 32 Channel Gas Detection Controller Overview

The all-new Beacon 3200 Gas Detection Controller is a versatile, advanced, fixed-system wall-mount controller for up to 32 gas-detection points. It can control up to 32 separate gas detection sensors. Sensor types can be direct-connect, 4-20 mA (2- or 3-wire), or Modbus transmitters. The Beacon 3200 can be powered by either 115 VAC, 220 VAC, or 24 VDC. A battery backup option is available and is trickle-charged by the Beacon 3200. It is simple to operate and comes complete with a wall-mount installation kit.

The large 7” colour LCD touchscreen can access control and maintenance functions as well as display all 32 channels. The Beacon 3200 is housed in a NEMA 4X-rated case for a weather-tight seal. This case design complies with lockout/tagout standards and can be fully secured. An external reset switch allows alarms to be silenced from outside the controller housing. Nine bottom-wiring hubs make wiring easy.

With an Ethernet port, the Beacon 3200 can output all channel data, including gas readings and alarm stats, via Modbus TCP/IP. This allows users to monitor the readings from a distance. RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilised with the Beacon 3200, providing gas monitoring protection for almost any application.

Related Services

Fixed Systems Turnkey Solutions

  • Design, Consultations, and Engineering
  • Installation
  • Start-up
  • Training
  • System Maintenance

Beacon 3200 32 Channel Gas Detection Controller Specifications

PHYSICAL
Dimensions Height: 16” (40.64 cm) x Width: 13.75” (34.93 cm) x Depth: 6.5” (16.51 cm)
Enclosure NEMA 4X fiberglass/polyester with lexan window for indoor and outdoor locations.
Conduit Connection 3/4” NPT conduit hubs, 9 provided, for sensor, power, & relay wiring.
Wiring Termination Screw type terminal block, 14 gauge max.
Power 115 VAC, 220 VAC, or 24 VDC nominal. Battery backup option available.
Optional Accessories Strobe light, and battery backup assembly.
Controls Touchscreen, reset button.

 

ENVIRONMENTAL
Operating Temperature -40°F to 122°F (-40°C to 50°C)
Storage Temperature -40°F to 158°F (-40°C to 70°C)
Enclosure Rating NEMA 4X enclosure, chemical and weather resistant. Suitable for indoor and outdoor installations.

 

INPUTS
Direct Wired Sensors LEL, Oxygen, Carbon Dioxide, and various toxic gas sensors.

Amplifier not required for less than 500 feet.

4-20 mA Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet. Compatible with: S2 Series, M2A, T2A, T3A, VOC Pro, Air Alert, GD-70D, and others.
Modbus Accepts M2A, T3A, VOC Pro, Air Alert.
Sampling Methods Diffusion and sample draw heads available.

 

OUTPUTS
Relays Four common Form C (C, NO, NC) relays (Fail, Alarm-1, Alarm-2, Alarm-3). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. Additional relays available on optional relay cards. 115/220VAC, 6A, or 30VDC contact relay.
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms output), per channel.
RS-485 Modbus Modbus format RS-485 serial output of all channel data, including gas reading and alarm status.
Ethernet Modbus TCP/IP output of all channel data, including gas readings and alarm status.
Display 7” Color LCD display of all 32 channels.
Audible Built-in audible alarm, 90 dB, mounted on enclosure.

Coded output: pulsing = gas alarm, steady = fail

Visual
  1. Touchscreen indications for each channel reading
    • Alarm 1 = yellow • Alarm 2 = orange • Alarm 3 = red • Fail = red
  2. An optional 24 VDC NEMA 4X strobe mounted to top of case.
Datalogging Included as standard for all 32 channels. Records to SD card.

 

APPROVALS  Shock and Fire Hazard
Warranty One year materials and workmanship.
Overview

Beacon 3200 32 Channel Gas Detection Controller Overview

The all-new Beacon 3200 Gas Detection Controller is a versatile, advanced, fixed-system wall-mount controller for up to 32 gas-detection points. It can control up to 32 separate gas detection sensors. Sensor types can be direct-connect, 4-20 mA (2- or 3-wire), or Modbus transmitters. The Beacon 3200 can be powered by either 115 VAC, 220 VAC, or 24 VDC. A battery backup option is available and is trickle-charged by the Beacon 3200. It is simple to operate and comes complete with a wall-mount installation kit.

The large 7” colour LCD touchscreen can access control and maintenance functions as well as display all 32 channels. The Beacon 3200 is housed in a NEMA 4X-rated case for a weather-tight seal. This case design complies with lockout/tagout standards and can be fully secured. An external reset switch allows alarms to be silenced from outside the controller housing. Nine bottom-wiring hubs make wiring easy.

With an Ethernet port, the Beacon 3200 can output all channel data, including gas readings and alarm stats, via Modbus TCP/IP. This allows users to monitor the readings from a distance. RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilised with the Beacon 3200, providing gas monitoring protection for almost any application.

Related Services

Fixed Systems Turnkey Solutions

  • Design, Consultations, and Engineering
  • Installation
  • Start-up
  • Training
  • System Maintenance
Specifications

Beacon 3200 32 Channel Gas Detection Controller Specifications

PHYSICAL
Dimensions Height: 16” (40.64 cm) x Width: 13.75” (34.93 cm) x Depth: 6.5” (16.51 cm)
Enclosure NEMA 4X fiberglass/polyester with lexan window for indoor and outdoor locations.
Conduit Connection 3/4” NPT conduit hubs, 9 provided, for sensor, power, & relay wiring.
Wiring Termination Screw type terminal block, 14 gauge max.
Power 115 VAC, 220 VAC, or 24 VDC nominal. Battery backup option available.
Optional Accessories Strobe light, and battery backup assembly.
Controls Touchscreen, reset button.

 

ENVIRONMENTAL
Operating Temperature -40°F to 122°F (-40°C to 50°C)
Storage Temperature -40°F to 158°F (-40°C to 70°C)
Enclosure Rating NEMA 4X enclosure, chemical and weather resistant. Suitable for indoor and outdoor installations.

 

INPUTS
Direct Wired Sensors LEL, Oxygen, Carbon Dioxide, and various toxic gas sensors.

Amplifier not required for less than 500 feet.

4-20 mA Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet. Compatible with: S2 Series, M2A, T2A, T3A, VOC Pro, Air Alert, GD-70D, and others.
Modbus Accepts M2A, T3A, VOC Pro, Air Alert.
Sampling Methods Diffusion and sample draw heads available.

 

OUTPUTS
Relays Four common Form C (C, NO, NC) relays (Fail, Alarm-1, Alarm-2, Alarm-3). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. Additional relays available on optional relay cards. 115/220VAC, 6A, or 30VDC contact relay.
4-20 mA Signal output, 4-20 mA (maximum load impedance 500 ohms output), per channel.
RS-485 Modbus Modbus format RS-485 serial output of all channel data, including gas reading and alarm status.
Ethernet Modbus TCP/IP output of all channel data, including gas readings and alarm status.
Display 7” Color LCD display of all 32 channels.
Audible Built-in audible alarm, 90 dB, mounted on enclosure.

Coded output: pulsing = gas alarm, steady = fail

Visual
  1. Touchscreen indications for each channel reading
    • Alarm 1 = yellow • Alarm 2 = orange • Alarm 3 = red • Fail = red
  2. An optional 24 VDC NEMA 4X strobe mounted to top of case.
Datalogging Included as standard for all 32 channels. Records to SD card.

 

APPROVALS  Shock and Fire Hazard
Warranty One year materials and workmanship.
Downloads

Enquire Now

Please provide a contact email and/or phone number: