Features
- Easy one-touch routine inspection
- Easy to use!
- Bump test and alarm test can be automatically performed with
- one-touch operation.
- Iconic display indicates the need for inspection at a glance
- Bump test and gas adjustment cycle (expiration date) can be set as desired.
- Icons display at a glance whether or not the due date has been reached.
- Up to 10 units can be connected for efficient daily inspections
- Reduces inspection time per unit.
Applications
- Personal Monitoring
- Refineries / Petrochemical
- Water / Wastewater Treatment
- Pharmaceuticals
- Chemical Plants
SDM-04 Single Gas Calibration Station Overview
Stand Alone Station
The SDM‐04 is a versatile maintenance tool that automates testing for a 04 Series portable gas monitor. This docking station can be used as a standalone device for charging, calibration and bump testing, with all records stored
automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Multi-Module System
Automate the management and servicing of 04 Series instruments by connecting the SDM‐04 to a computer via a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, or archive data. Also, download the data logging history from each instrument into a single, easy-to-manage locator. SDM-04 stations can be manifolded to reduce the number of demand-flow regulator gas cylinders required.
|
|
SDM-04 Single Gas Calibration Station Specifications
| Model | SDM‐04(C1) | SDM‐04(C2) | SDM‐04(C3) | SDM‐04(C4) | SDM‐04(C5) | ||
| Number of inlets | Air | 1 | 1 | 1 | 1 | 1 | |
| Gas | 1 (GAS1) | 2 (GAS1,GAS2) | 3 (GAS1,GAS2, GAS3) | 2 (GAS1,GAS3) | 1 (GAS3) | ||
| Compatible gas detector | OX‐04G, OX‐04, CO‐04, CO‐04(C‐), CX‐04, HS‐04 | OX‐04G, OX‐04, CO‐04, CO‐04(C‐), CX‐04, HS‐04, SC‐04(SO2), SC‐04(NO2), SC‐04(HCN), SC‐04(PH3), SC‐04(NH3) * | |||||
| Display | LCD digital (full dot) | ||||||
| Status display | LED (Green, orange, red /Steady light, blinking) | ||||||
| Interface | USB (for USB flash device, PC communication), LAN | ||||||
| PC communication | Wired connection (USB cable, LAN cable) | ||||||
| Number of units that can be connected | Up to 10 units ** | ||||||
| Data storage capacity | Up to 500 items (bump test, calibration, alarm check) | ||||||
| Input power supply | 100 to 240 V AC, 50/60Hz (AC adapter) | ||||||
| Operating temp range | 0 to 40 °C (no sudden changes) *** | ||||||
| Operating humidity range | 0 to 95 %RH (no condensation) | ||||||
| External dimensions | Approx.130(W) x 150(H) x 272(D)mm | ||||||
| Weight | Approx. 1.1 kg | ||||||
| *When SO2, NO2, HCN, PH3, or NH3 is used as a calibration gas, the gas must be introduced through GAS3. **Interconnection is not possible when using SO2, NO2, HCN, PH3, or NH3 as the calibration gas. ***When SO2, NO2, or NH3 is used as a calibration gas: 10 to 40 ̊C (with no sudden changes) |
|||||||
- Overview
-
SDM-04 Single Gas Calibration Station Overview
Stand Alone Station
The SDM‐04 is a versatile maintenance tool that automates testing for a 04 Series portable gas monitor. This docking station can be used as a standalone device for charging, calibration and bump testing, with all records stored
automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Multi-Module System
Automate the management and servicing of 04 Series instruments by connecting the SDM‐04 to a computer via a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, or archive data. Also, download the data logging history from each instrument into a single, easy-to-manage locator. SDM-04 stations can be manifolded to reduce the number of demand-flow regulator gas cylinders required.
- Multiple modules connected to a PC (10 max)
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure 04 Series parameters
- Archive Bump Test and Calibration records
- Archive data to the network location
- Software-controlled data retrieval
- Windows 7 compatible
- Specifications
-
SDM-04 Single Gas Calibration Station Specifications
Model SDM‐04(C1) SDM‐04(C2) SDM‐04(C3) SDM‐04(C4) SDM‐04(C5) Number of inlets Air 1 1 1 1 1 Gas 1 (GAS1) 2 (GAS1,GAS2) 3 (GAS1,GAS2, GAS3) 2 (GAS1,GAS3) 1 (GAS3) Compatible gas detector OX‐04G, OX‐04, CO‐04, CO‐04(C‐), CX‐04, HS‐04 OX‐04G, OX‐04, CO‐04, CO‐04(C‐), CX‐04, HS‐04, SC‐04(SO2), SC‐04(NO2), SC‐04(HCN), SC‐04(PH3), SC‐04(NH3) * Display LCD digital (full dot) Status display LED (Green, orange, red /Steady light, blinking) Interface USB (for USB flash device, PC communication), LAN PC communication Wired connection (USB cable, LAN cable) Number of units that can be connected Up to 10 units ** Data storage capacity Up to 500 items (bump test, calibration, alarm check) Input power supply 100 to 240 V AC, 50/60Hz (AC adapter) Operating temp range 0 to 40 °C (no sudden changes) *** Operating humidity range 0 to 95 %RH (no condensation) External dimensions Approx.130(W) x 150(H) x 272(D)mm Weight Approx. 1.1 kg *When SO2, NO2, HCN, PH3, or NH3 is used as a calibration gas, the gas must be introduced through GAS3.
**Interconnection is not possible when using SO2, NO2, HCN, PH3, or NH3 as the calibration gas.
***When SO2, NO2, or NH3 is used as a calibration gas: 10 to 40 ̊C (with no sudden changes) - Downloads