OHC-800 Explosion-proof Calorimeter

OHC-800 Explosion-proof Calorimeter from Riken

Features

  • Unique measuring principle,”Opt-Sonic calculation” is applied
  • This can minimise the interference effects caused by interference gases, and a high-accuracy measuring result can be obtained
  • Fast response time T90 reaction within 5 seconds
  • High repeatability +/- 0.02MJ/m3
  • Wide operation temperature -20 ~ +57 degree C
  • Explosion-Proof structure even for Hydrogen Exd IIB
  • High ingress protection level IP66 / IP67
  • Remarkable temperature characteristic
  • Below 0.10MJ/m3 fluctuation for the temperature change in a day (< 20 degree C)
  • Easy to switch the display among “Calorific value”, “Density” and “WOBBE index” just by the button operation

Applications

  • Electric Power Energy
  • Gas Energy
  • Gas Engine for Ship
  • Biogas
  • Iron Steel
  • Refinery

Explosion-proof Calorimeter OHC-800 Overview

The OHC-800 is an all-in-one explosion-proof calorimeter which features high accuracy, continuous measurement and high-speed response.

“Opt-Sonic calculation” is performed using the optical and sonic sensors. “Opt-Sonic calculation” is based on combining 2 measurement results obtained by the 2 sensors. This can minimise the effects of interference gases on the reading and enable high-accuracy, reliable measurement. (* Opt-Sonic is a term coined by RIKEN KEIKI to describe Optical and Sonic sensors)

  • Easy to switch the display among “Calorific value”, “Density” and “WOBBE index”
    The displayed unit is easily switched by pressing the button. Laborious calculation is not needed.
  • Fulfilling self-diagnosis function and running cost. The self-diagnosis function, including fault diagnostics, prevents the calorimeter from becoming unable to measure the gas. Few consumables are needed, and this saves on running costs.
  • Designed to be installed in a wide variety of locations.
    Structure is robust with Explosion-Proof (Exd IIB+H2 T4) and high ingress protection level (IP66 / IP67) Both 100VAC~240VAC and 24VDC power supply can be supplied.

Explosion-proof Calorimeter OHC-800 Specifications

Model OHC-800
Measuring principle Opt-Sonic calculation through measurement of refractive index and sound speed
Measuring gas CH4 basis Paraffinic Hydrocarbon gases as represented by Natural Gas *1
Measuring targets Calorific value (Density / WOBBE index selectable)
Measuring range *2 Calorific value : 25.00~50.00 MJ/㎥ (Gross, 0 degree C, 101.325kPa converted) Density : 0.500~1.500 MJ/㎥
(Specific gravity converted)
Measuring method Constant-flow-rate gas introduction using external sampling devices
Display Full-dot LCD (with backlight), 3 color LED lamp
External Output 4-20 mA DC (isolated, source current type) maximum load resistance of 300 Ω / RS-485 communication
FAILURE alarm Low flow, Sensor unit abnormality, Low light amount
FAILURE alarm display Lamp (red) / Content indication on LCD
FAILURE alarm contact *3 No-voltage contact 1a or 1b De-energise (Energise when alarming) or Energise (De-energise when alarming) Contact capacity of 2 A, 30 VDC (resistance load)
Self-diagnostic function FUNCTION CHECK (warm-up or maintenance mode), MAINTENANCE REQUIRED, OUT OF SPECIFICATION
Self-diagnostic display FUNCTION CHECK, OUT OF SPECIFICATION : Lamp (orange)/Content indication on LCD MAINTENANCE REQUIRED : Lamp (green) / Content indication on LCD
Self-diagnostic contact FUNCTION CHECK, OUT OF SPECIFICATION : No-voltage contact 1a or 1b De-energise (Energise when alarming) or Energise (De-energise when alarming) Contact
capacity of 2 A, 30 VDC (resistance load)
MAINTENANCE REQUIRED : SSR contact, contact capacity of 20 W, 240 VAC (resistance load)
Power supply 100 – 240 VAC ±10%, 50/60 Hz, max. 18 VA or 24 VDC ±10%, max. 5 W (The setting can be
changed to either the AC or DC)
Ingress Protection level Equivalent to IP66 and IP67
Operation temperature -20~+57 degree C(TIIS)/-20~+60 degree C(ATEX/IECEx)
Operation humidity 95%RH or less (no condensing)
Outer dimensions / Weight Approx. 286 (W) x 453 (H) x 150 (D) mm / Approx. 23 kg
Explosion-Proof structure Flame-proof enclosures (Explosion-proof class: ExdⅡB+H2 T4 <TIIS>/Ⅱ2GExdⅡB+H2T4 <ATEX/IECEx>)

 

*1 Total concentration of interference gases such as N2, O2, CO2, CO etc. contained in a target gas is estimated as less than 20%

*2 Contact Control Equipment Pty Ltd for the other measuring ranges

*3 Contact setting is adjustable

Overview

Explosion-proof Calorimeter OHC-800 Overview

The OHC-800 is an all-in-one explosion-proof calorimeter which features high accuracy, continuous measurement and high-speed response.

“Opt-Sonic calculation” is performed using the optical and sonic sensors. “Opt-Sonic calculation” is based on combining 2 measurement results obtained by the 2 sensors. This can minimise the effects of interference gases on the reading and enable high-accuracy, reliable measurement. (* Opt-Sonic is a term coined by RIKEN KEIKI to describe Optical and Sonic sensors)

  • Easy to switch the display among “Calorific value”, “Density” and “WOBBE index”
    The displayed unit is easily switched by pressing the button. Laborious calculation is not needed.
  • Fulfilling self-diagnosis function and running cost. The self-diagnosis function, including fault diagnostics, prevents the calorimeter from becoming unable to measure the gas. Few consumables are needed, and this saves on running costs.
  • Designed to be installed in a wide variety of locations.
    Structure is robust with Explosion-Proof (Exd IIB+H2 T4) and high ingress protection level (IP66 / IP67) Both 100VAC~240VAC and 24VDC power supply can be supplied.
Specifications

Explosion-proof Calorimeter OHC-800 Specifications

Model OHC-800
Measuring principle Opt-Sonic calculation through measurement of refractive index and sound speed
Measuring gas CH4 basis Paraffinic Hydrocarbon gases as represented by Natural Gas *1
Measuring targets Calorific value (Density / WOBBE index selectable)
Measuring range *2 Calorific value : 25.00~50.00 MJ/㎥ (Gross, 0 degree C, 101.325kPa converted) Density : 0.500~1.500 MJ/㎥
(Specific gravity converted)
Measuring method Constant-flow-rate gas introduction using external sampling devices
Display Full-dot LCD (with backlight), 3 color LED lamp
External Output 4-20 mA DC (isolated, source current type) maximum load resistance of 300 Ω / RS-485 communication
FAILURE alarm Low flow, Sensor unit abnormality, Low light amount
FAILURE alarm display Lamp (red) / Content indication on LCD
FAILURE alarm contact *3 No-voltage contact 1a or 1b De-energise (Energise when alarming) or Energise (De-energise when alarming) Contact capacity of 2 A, 30 VDC (resistance load)
Self-diagnostic function FUNCTION CHECK (warm-up or maintenance mode), MAINTENANCE REQUIRED, OUT OF SPECIFICATION
Self-diagnostic display FUNCTION CHECK, OUT OF SPECIFICATION : Lamp (orange)/Content indication on LCD MAINTENANCE REQUIRED : Lamp (green) / Content indication on LCD
Self-diagnostic contact FUNCTION CHECK, OUT OF SPECIFICATION : No-voltage contact 1a or 1b De-energise (Energise when alarming) or Energise (De-energise when alarming) Contact
capacity of 2 A, 30 VDC (resistance load)
MAINTENANCE REQUIRED : SSR contact, contact capacity of 20 W, 240 VAC (resistance load)
Power supply 100 – 240 VAC ±10%, 50/60 Hz, max. 18 VA or 24 VDC ±10%, max. 5 W (The setting can be
changed to either the AC or DC)
Ingress Protection level Equivalent to IP66 and IP67
Operation temperature -20~+57 degree C(TIIS)/-20~+60 degree C(ATEX/IECEx)
Operation humidity 95%RH or less (no condensing)
Outer dimensions / Weight Approx. 286 (W) x 453 (H) x 150 (D) mm / Approx. 23 kg
Explosion-Proof structure Flame-proof enclosures (Explosion-proof class: ExdⅡB+H2 T4 <TIIS>/Ⅱ2GExdⅡB+H2T4 <ATEX/IECEx>)

 

*1 Total concentration of interference gases such as N2, O2, CO2, CO etc. contained in a target gas is estimated as less than 20%

*2 Contact Control Equipment Pty Ltd for the other measuring ranges

*3 Contact setting is adjustable

Downloads

Enquire Now