2 Channel Wall Mount Gas Detection Controller – Beacon 200

This low cost fixed system 2 Channel Gas Detection Controller is designed to accept up to two points of gas detection. It is capable of connecting directly to a variety of gas sensors. The Beacon 200 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC).

2 Channel Gas Detection Controller Features:

  • Simultaneous readout on 2 channels
  • Two alarm levels per channel
  • Discrete and common relays
  • NEMA 4X enclosure
  • 4 – 20 mA outputs
  • Proven, long life sensors for a wide variety of gases
  • Accepts any 4 – 20 mA transmitter input
  • Easy to install, operate and expand
  • Intrinsically safe design
  • Min/max display

Application/s:

  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone & electric utilities
  • Carparks
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC

2 Channel Gas Detection Controller Overview:

This low cost fixed system controller is designed to accept up to two points of gas detection. It is capable of connecting directly to a variety of gas sensors. The Beacon 200 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC).

The Beacon 200 is capable of connecting RKI sensors directly for LEL level combustibles, oxygen, hydrogen sulphide or carbon monoxide. The Beacon 200 can also accept any 4 – 20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 200 housing, or can be wired remotely from the controller.

The 10 amp rated relays are strong enough to directly power external alarms and horns without using slave relays. The digital display has backlighting and simultaneous readout of the gas type and concentration.

The Beacon 200’s housing is NEMA 4X rated for a weather tight seal and complies with lock out/tag out standards. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 200 comes complete with a wall mounting kit for easy installation.

2 Channel Gas Detection Controller Specifications:

Physical
Dimensions: Height 216mm Width 178 mm Depth: 109 mm

 

Enclosure: Wall mounting grey polycarbonate with hinged cover

 

Conduit Connection:

 

3/4” NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power and relay wiring
Wiring Termination:

 

Screw type terminal block 14 gauge max

 

Power: 240 VAC or 24 VDC. Optional – 115 VAC. Battery backup option available.
Controls:

 

4 internal push buttons for setup, programming and calibration. 1 external push button for alarm reset.

 

Environmental

 

Operating Temp:

 

-20°C to 50°C

 

Storage Temp:

 

-20°C to 70°C

 

Relative Humidity:

 

0 – 100% RH

 

Enclosure Rating:

 

NEMA-4X enclosure, waterproof, chemical and weather resistant

 

Inputs
Direct Wired Sensors:

 

LEL/PPM Hydrocarbon, Oxygen, Carbon Monoxide, Hydrogen Sulphide, Chlorine, Sulphur Dioxide. Remote amp not required for less than 15 metres

 

4-20 mA Sensors:

 

Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. Wiring distances up to 5,000 meters

 

Sampling methods:

 

Diffusion and sample draw heads available
Outputs

 

Relays:

 

4 relays – 10 amp rating, SPDT isolated contacts. 2 relays for gas alarm levels, 1 relay for malfunction. Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off

 

4-20 mA:

 

Signal output, 4-20 mA (into 1000 ohms impedance maximum)

 

24 VDC:

 

24 VDC (350 mA max) output provided to operate sample draw adapters or other accessories

 

Display:

 

Alphanumeric display with backlighting. 20 characters per line; 4 lines each

 

Audible:

 

Built-in audible alarm, 94 dB, mounted on enclosure. Coded output: Pulsing = gas alarm, Steady = fail

 

Visual:

 

4 visual LED alarms on front cover for status indication, pilot and malfunction

 

Warranty:

 

1 year materials and workmanship

 

Gases Detected:

Ammonia (NH3) 0 – 75.0 ppm
Arsine (AsH3) 0 – 0.2 ppm
Boron Trichloride (BCl3) 0 – 15.0 ppm
Carbon Dioxide (CO2) 0 – 1.0 %
Carbon Monoxide (CO) 0 – 300 ppm
Chlorine (Cl2) 0 – 3.0 ppm
Chlorine Dioxide (ClO2) 0 – 1.0 ppm
Chlorine Trifluoride (CIF3) 0 – 1.0 ppm
Combustibles 0 – 100% LEL
Diborane (B2H6) 0 – 30.0 ppm
Fluorine (F2) 0 – 5/15 ppm
Hydrogen (H2) 0 – 2000 ppm
Hydrogen Chloride (HCl) 0 – 15.0 ppm
Hydrogen Fluoride (HF) 0 – 9.0 ppm
Hydrogen Sulfide (H2S) 0 – 100.0 ppm
Nitric Oxide (NO) 0 – 100.0 ppm
Nitrogen Dioxide (NO2) 0 – 15.0 ppm
Nitrogen Trifluoride (NF3) 0 – 30.0 ppm
Oxygen (O2) 0 – 25.0%
Ozone (O3) 0 – 1.0 ppm
Phosphine (PH3) 0 – 1.0 ppm
Silane (SiH4) 0 – 15.0 ppm
Sulphur Dioxide (SO2) 0 – 30.0 ppm
TEOS (Si(OC2H5)4) 0 – 15/30 ppm

2 Channel Gas Detection Controller Downloads:

Specifications:

Overview

2 Channel Gas Detection Controller Overview:

This low cost fixed system controller is designed to accept up to two points of gas detection. It is capable of connecting directly to a variety of gas sensors. The Beacon 200 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC).

The Beacon 200 is capable of connecting RKI sensors directly for LEL level combustibles, oxygen, hydrogen sulphide or carbon monoxide. The Beacon 200 can also accept any 4 – 20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 200 housing, or can be wired remotely from the controller.

The 10 amp rated relays are strong enough to directly power external alarms and horns without using slave relays. The digital display has backlighting and simultaneous readout of the gas type and concentration.

The Beacon 200’s housing is NEMA 4X rated for a weather tight seal and complies with lock out/tag out standards. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 200 comes complete with a wall mounting kit for easy installation.

Specifications

2 Channel Gas Detection Controller Specifications:

Physical
Dimensions: Height 216mm Width 178 mm Depth: 109 mm

 

Enclosure: Wall mounting grey polycarbonate with hinged cover

 

Conduit Connection:

 

3/4” NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power and relay wiring
Wiring Termination:

 

Screw type terminal block 14 gauge max

 

Power: 240 VAC or 24 VDC. Optional – 115 VAC. Battery backup option available.
Controls:

 

4 internal push buttons for setup, programming and calibration. 1 external push button for alarm reset.

 

Environmental

 

Operating Temp:

 

-20°C to 50°C

 

Storage Temp:

 

-20°C to 70°C

 

Relative Humidity:

 

0 – 100% RH

 

Enclosure Rating:

 

NEMA-4X enclosure, waterproof, chemical and weather resistant

 

Inputs
Direct Wired Sensors:

 

LEL/PPM Hydrocarbon, Oxygen, Carbon Monoxide, Hydrogen Sulphide, Chlorine, Sulphur Dioxide. Remote amp not required for less than 15 metres

 

4-20 mA Sensors:

 

Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. Wiring distances up to 5,000 meters

 

Sampling methods:

 

Diffusion and sample draw heads available
Outputs

 

Relays:

 

4 relays – 10 amp rating, SPDT isolated contacts. 2 relays for gas alarm levels, 1 relay for malfunction. Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off

 

4-20 mA:

 

Signal output, 4-20 mA (into 1000 ohms impedance maximum)

 

24 VDC:

 

24 VDC (350 mA max) output provided to operate sample draw adapters or other accessories

 

Display:

 

Alphanumeric display with backlighting. 20 characters per line; 4 lines each

 

Audible:

 

Built-in audible alarm, 94 dB, mounted on enclosure. Coded output: Pulsing = gas alarm, Steady = fail

 

Visual:

 

4 visual LED alarms on front cover for status indication, pilot and malfunction

 

Warranty:

 

1 year materials and workmanship

 

Gases Detected

Gases Detected:

Ammonia (NH3) 0 – 75.0 ppm
Arsine (AsH3) 0 – 0.2 ppm
Boron Trichloride (BCl3) 0 – 15.0 ppm
Carbon Dioxide (CO2) 0 – 1.0 %
Carbon Monoxide (CO) 0 – 300 ppm
Chlorine (Cl2) 0 – 3.0 ppm
Chlorine Dioxide (ClO2) 0 – 1.0 ppm
Chlorine Trifluoride (CIF3) 0 – 1.0 ppm
Combustibles 0 – 100% LEL
Diborane (B2H6) 0 – 30.0 ppm
Fluorine (F2) 0 – 5/15 ppm
Hydrogen (H2) 0 – 2000 ppm
Hydrogen Chloride (HCl) 0 – 15.0 ppm
Hydrogen Fluoride (HF) 0 – 9.0 ppm
Hydrogen Sulfide (H2S) 0 – 100.0 ppm
Nitric Oxide (NO) 0 – 100.0 ppm
Nitrogen Dioxide (NO2) 0 – 15.0 ppm
Nitrogen Trifluoride (NF3) 0 – 30.0 ppm
Oxygen (O2) 0 – 25.0%
Ozone (O3) 0 – 1.0 ppm
Phosphine (PH3) 0 – 1.0 ppm
Silane (SiH4) 0 – 15.0 ppm
Sulphur Dioxide (SO2) 0 – 30.0 ppm
TEOS (Si(OC2H5)4) 0 – 15/30 ppm
Downloads

2 Channel Gas Detection Controller Downloads:

Specifications:

Enquire Now

    Name*

    Phone*

    Location*

    If Other

    Email*

    How did you hear about us?*

    What are you interested in?*

    Message