Beacon 110 Single Channel Gas Detection Controller

Beacon 110 Single Channel Gas Detection Controller

Features

  • Low cost versatile solution
  • Compact, weatherproof, NEMA 4X enclosure
  • Accepts RKI LEL/O2/H2S/CO direct connect sensors
  • 115/220 VAC or 24 VDC operation
  • Long life sensors (2+ years typical)
  • Accepts any 4-20 mA transmitter
  • Audible alarm with reset button
  • Two programmable alarm levels
  • Built-in trouble alarm with relay
  • Relay rating 10 amps, form C
  • Provides 4-20 mA output

 

Applications

  • Laboratories
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Manufacturing facilities
  • HVAC
  • Gas, telephone, & electric utilities
  • Steel

Beacon 110 Single-Channel Gas Detection Controller Overview

The Beacon 110 is a powerful, low-cost, fixed, single-channel gas detection controller for a single gas detection point. The Beacon 110 is also housed in a NEMA 4X-rated case for a weather-tight seal. An external reset switch allows the alarm to be silenced from outside of the controller housing.

The Beacon 110 can accept RKI sensors directly for oxygen, hydrogen sulphide, or carbon monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2- or 3-wire, 24 VDC), making it a very handy controller for single-channel toxic applications. Sensors can be mounted directly at the Beacon 110 housing or can be wired remotely from the controller.

The 10-amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneously displays the gas type and concentration.

This case design complies with lockout / tagout standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships with a wall-mounting kit for easy installation.

Beacon 110 Single Channel Gas Detection Controller Specifications

­­­PHYSICAL
Dimensions Height: 216 mm Width: 178 mm Depth: 109 mm

 

Enclosure Wall mounting grey polycarbonate with hinged cover.

 

Conduit Connection 3/4” NPT conduit hubs, 2 provided, 1 for sensor wiring and 1 for  power and relay wiring.
Wiring Termination Screw type terminal block 14 gauge max.
ENVIRONMENTAL
Operating Temp -20°C to 50°C
Storage Temp -20°C to 70°C
Relative Humidity 0 – 100% RH
Enclosure Rating NEMA-4X enclosure, waterproof, chemical and weather resistant.
INPUTS
4-20 mA Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire).  Wiring distances up to 1,500 metres.
Sampling methods: Diffusion and sample draw heads available. Carbon Monoxide (CO) 0 – 300 ppm, Combustibles 0 -100% LEL, Nitrogen Dioxide (NO2) 0 – 15.0 ppm  (Refer to list of detectable Gases for additional ranges).
OUTPUTS
Relays 3 Relays – 10 amp rating, SPDT isolated contacts. 2 for gas alarm levels and 1 trouble relay.  Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off.
24 VDC 24 VDC (400 mA max) output provided to operate sample drawing adaptors or other accessories
Display 2 x 8 Alphanumeric display with backlighting.
Audible Built-in audible alarm, 94 dB, mounted on enclosure.  Coded output: Pulsing = gas alarm, Steady = fail
Visual 3 Visual LED alarms on front cover for alarm indications and malfunction.
Power 240 VAC or 24 VDC.  Optional – 115 VAC.  Battery backup option available.
Warranty One year materials and workmanship.

Beacon 110 Single Channel Gas Detection Controller Gases Detected:

Ammonia (NH3) 0 – 75.0 ppm
Arsine (AsH3) 0 – 0.2 ppm
Boron Trichloride (BCl3) 0 – 15.0 ppm
Carbon Dioxide (CO2) 0 – 1.0 %
Carbon Monoxide (CO) 0 – 300 ppm
Chlorine (Cl2) 0 – 3.0 ppm
Chlorine Dioxide (ClO2) 0 – 1.0 ppm
Chlorine Trifluoride (CIF3) 0 – 1.0 ppm
Combustibles 0 – 100% LEL
Diborane (B2H6) 0 – 30.0 ppm
Fluorine (F2) 0 – 5/15 ppm
Hydrogen (H2) 0 – 2000 ppm
Hydrogen Chloride (HCl) 0 – 15.0 ppm
Hydrogen Fluoride (HF) 0 – 9.0 ppm
Hydrogen Sulfide (H2S) 0 – 100.0 ppm
Nitric Oxide (NO) 0 – 100.0 ppm
Nitrogen Dioxide (NO2) 0 – 15.0 ppm
Nitrogen Trifluoride (NF3) 0 – 30.0 ppm
Oxygen (O2) 0 – 25.0%
Ozone (O3) 0 – 1.0 ppm
Phosphine (PH3) 0 – 1.0 ppm
Silane (SiH4) 0 – 15.0 ppm
Sulphur Dioxide (SO2) 0 – 30.0 ppm
TEOS (Si(OC2H5)4) 0 – 15/30 ppm
Overview

Beacon 110 Single-Channel Gas Detection Controller Overview

The Beacon 110 is a powerful, low-cost, fixed, single-channel gas detection controller for a single gas detection point. The Beacon 110 is also housed in a NEMA 4X-rated case for a weather-tight seal. An external reset switch allows the alarm to be silenced from outside of the controller housing.

The Beacon 110 can accept RKI sensors directly for oxygen, hydrogen sulphide, or carbon monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2- or 3-wire, 24 VDC), making it a very handy controller for single-channel toxic applications. Sensors can be mounted directly at the Beacon 110 housing or can be wired remotely from the controller.

The 10-amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneously displays the gas type and concentration.

This case design complies with lockout / tagout standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships with a wall-mounting kit for easy installation.

Specifications

Beacon 110 Single Channel Gas Detection Controller Specifications

­­­PHYSICAL
Dimensions Height: 216 mm Width: 178 mm Depth: 109 mm

 

Enclosure Wall mounting grey polycarbonate with hinged cover.

 

Conduit Connection 3/4” NPT conduit hubs, 2 provided, 1 for sensor wiring and 1 for  power and relay wiring.
Wiring Termination Screw type terminal block 14 gauge max.
ENVIRONMENTAL
Operating Temp -20°C to 50°C
Storage Temp -20°C to 70°C
Relative Humidity 0 – 100% RH
Enclosure Rating NEMA-4X enclosure, waterproof, chemical and weather resistant.
INPUTS
4-20 mA Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire).  Wiring distances up to 1,500 metres.
Sampling methods: Diffusion and sample draw heads available. Carbon Monoxide (CO) 0 – 300 ppm, Combustibles 0 -100% LEL, Nitrogen Dioxide (NO2) 0 – 15.0 ppm  (Refer to list of detectable Gases for additional ranges).
OUTPUTS
Relays 3 Relays – 10 amp rating, SPDT isolated contacts. 2 for gas alarm levels and 1 trouble relay.  Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off.
24 VDC 24 VDC (400 mA max) output provided to operate sample drawing adaptors or other accessories
Display 2 x 8 Alphanumeric display with backlighting.
Audible Built-in audible alarm, 94 dB, mounted on enclosure.  Coded output: Pulsing = gas alarm, Steady = fail
Visual 3 Visual LED alarms on front cover for alarm indications and malfunction.
Power 240 VAC or 24 VDC.  Optional – 115 VAC.  Battery backup option available.
Warranty One year materials and workmanship.
Gases Detected

Beacon 110 Single Channel Gas Detection Controller Gases Detected:

Ammonia (NH3) 0 – 75.0 ppm
Arsine (AsH3) 0 – 0.2 ppm
Boron Trichloride (BCl3) 0 – 15.0 ppm
Carbon Dioxide (CO2) 0 – 1.0 %
Carbon Monoxide (CO) 0 – 300 ppm
Chlorine (Cl2) 0 – 3.0 ppm
Chlorine Dioxide (ClO2) 0 – 1.0 ppm
Chlorine Trifluoride (CIF3) 0 – 1.0 ppm
Combustibles 0 – 100% LEL
Diborane (B2H6) 0 – 30.0 ppm
Fluorine (F2) 0 – 5/15 ppm
Hydrogen (H2) 0 – 2000 ppm
Hydrogen Chloride (HCl) 0 – 15.0 ppm
Hydrogen Fluoride (HF) 0 – 9.0 ppm
Hydrogen Sulfide (H2S) 0 – 100.0 ppm
Nitric Oxide (NO) 0 – 100.0 ppm
Nitrogen Dioxide (NO2) 0 – 15.0 ppm
Nitrogen Trifluoride (NF3) 0 – 30.0 ppm
Oxygen (O2) 0 – 25.0%
Ozone (O3) 0 – 1.0 ppm
Phosphine (PH3) 0 – 1.0 ppm
Silane (SiH4) 0 – 15.0 ppm
Sulphur Dioxide (SO2) 0 – 30.0 ppm
TEOS (Si(OC2H5)4) 0 – 15/30 ppm
Downloads

Enquire Now

Please provide a contact email and/or phone number: