Features:
- Low cost versatile solution
- Compact, weatherproof, NEMA 4X enclosure
- Accepts RKI LEL/O2/H2S/CO direct connect sensors
- 115/220 VAC or 24 VDC operation
- Long life sensors (2+ years typical)
- Accepts any 4-20 mA transmitter
- Audible alarm with reset button
- Two programmable alarm levels
- Built-in trouble alarm with relay
- Relay rating 10 amps, form C
- Provides 4-20 mA output
Application/s:
- Laboratories
- Petrochemical plants
- Refineries
- Water & wastewater treatment plants
- Pulp & paper mills
- Manufacturing facilities
- HVAC
- Gas, telephone, & electric utilities
- Steel
Overview:
The Beacon 110 is a powerful, low cost fixed system Single Channel Gas Detection controller for one point of gas detection. The Beacon 110 is also housed in a NEMA 4X rated case for a weather tight seal. An external reset switch allows the alarm to be silenced from outside of the controller housing.
The Beacon 110 is capable of accepting RKI sensors directly for oxygen, hydrogen sulphide or carbon monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC) which make it a very handy controller for single channel toxic applications. Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.
The 10 amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneous readout of the gas type and concentration.
This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships complete with a wall mounting kit for easy installation.
Specifications:
Physical | |
Dimensions: | Height: 216 mm Width: 178 mm Depth: 109 mm
|
Enclosure: | Wall mounting grey polycarbonate with hinged cover.
|
Conduit Connection: | 3/4” NPT conduit hubs, 2 provided, 1 for sensor wiring and 1 for power and relay wiring. |
Wiring Termination: | Screw type terminal block 14 gauge max. |
Environmental | |
Operating Temp: | -20°C to 50°C |
Storage Temp: | -20°C to 70°C |
Relative Humidity: | 0 – 100% RH |
Enclosure Rating: | NEMA-4X enclosure, waterproof, chemical and weather resistant. |
Inputs | |
4-20 mA | Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire). Wiring distances up to 1,500 metres. |
Sampling methods: | Diffusion and sample draw heads available. Carbon Monoxide (CO) 0 – 300 ppm, Combustibles 0 -100% LEL, Nitrogen Dioxide (NO2) 0 – 15.0 ppm (Refer to list of detectable Gases for additional ranges). |
Outputs | |
Relays: | 3 Relays – 10 amp rating, SPDT isolated contacts. 2 for gas alarm levels and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off. |
24 VDC: | 24 VDC (400 mA max) output provided to operate sample drawing adaptors or other accessories |
Display: | 2 x 8 Alphanumeric display with backlighting. |
Audible: | Built-in audible alarm, 94 dB, mounted on enclosure. Coded output: Pulsing = gas alarm, Steady = fail |
Visual: | 3 Visual LED alarms on front cover for alarm indications and malfunction. |
Power: | 240 VAC or 24 VDC. Optional – 115 VAC. Battery backup option available. |
Warranty: | One year materials and workmanship. |
Gases Detected:
Ammonia (NH3) | 0 – 75.0 ppm |
Arsine (AsH3) | 0 – 0.2 ppm |
Boron Trichloride (BCl3) | 0 – 15.0 ppm |
Carbon Dioxide (CO2) | 0 – 1.0 % |
Carbon Monoxide (CO) | 0 – 300 ppm |
Chlorine (Cl2) | 0 – 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 – 1.0 ppm |
Chlorine Trifluoride (CIF3) | 0 – 1.0 ppm |
Combustibles | 0 – 100% LEL |
Diborane (B2H6) | 0 – 30.0 ppm |
Fluorine (F2) | 0 – 5/15 ppm |
Hydrogen (H2) | 0 – 2000 ppm |
Hydrogen Chloride (HCl) | 0 – 15.0 ppm |
Hydrogen Fluoride (HF) | 0 – 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 – 100.0 ppm |
Nitric Oxide (NO) | 0 – 100.0 ppm |
Nitrogen Dioxide (NO2) | 0 – 15.0 ppm |
Nitrogen Trifluoride (NF3) | 0 – 30.0 ppm |
Oxygen (O2) | 0 – 25.0% |
Ozone (O3) | 0 – 1.0 ppm |
Phosphine (PH3) | 0 – 1.0 ppm |
Silane (SiH4) | 0 – 15.0 ppm |
Sulphur Dioxide (SO2) | 0 – 30.0 ppm |
TEOS (Si(OC2H5)4) | 0 – 15/30 ppm |
- Overview
-
Overview:
The Beacon 110 is a powerful, low cost fixed system Single Channel Gas Detection controller for one point of gas detection. The Beacon 110 is also housed in a NEMA 4X rated case for a weather tight seal. An external reset switch allows the alarm to be silenced from outside of the controller housing.
The Beacon 110 is capable of accepting RKI sensors directly for oxygen, hydrogen sulphide or carbon monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC) which make it a very handy controller for single channel toxic applications. Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.
The 10 amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneous readout of the gas type and concentration.
This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships complete with a wall mounting kit for easy installation.
- Specifications
-
Specifications:
Physical Dimensions: Height: 216 mm Width: 178 mm Depth: 109 mm Enclosure: Wall mounting grey polycarbonate with hinged cover. Conduit Connection: 3/4” NPT conduit hubs, 2 provided, 1 for sensor wiring and 1 for power and relay wiring. Wiring Termination: Screw type terminal block 14 gauge max. Environmental Operating Temp: -20°C to 50°C Storage Temp: -20°C to 70°C Relative Humidity: 0 – 100% RH Enclosure Rating: NEMA-4X enclosure, waterproof, chemical and weather resistant. Inputs 4-20 mA Accepts any 4-20 mA transmitters (24 VDC, 2 or 3 wire). Wiring distances up to 1,500 metres. Sampling methods: Diffusion and sample draw heads available. Carbon Monoxide (CO) 0 – 300 ppm, Combustibles 0 -100% LEL, Nitrogen Dioxide (NO2) 0 – 15.0 ppm (Refer to list of detectable Gases for additional ranges). Outputs Relays: 3 Relays – 10 amp rating, SPDT isolated contacts. 2 for gas alarm levels and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarms, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off. 24 VDC: 24 VDC (400 mA max) output provided to operate sample drawing adaptors or other accessories Display: 2 x 8 Alphanumeric display with backlighting. Audible: Built-in audible alarm, 94 dB, mounted on enclosure. Coded output: Pulsing = gas alarm, Steady = fail Visual: 3 Visual LED alarms on front cover for alarm indications and malfunction. Power: 240 VAC or 24 VDC. Optional – 115 VAC. Battery backup option available. Warranty: One year materials and workmanship. - Gases Detected
-
Gases Detected:
Ammonia (NH3) 0 – 75.0 ppm Arsine (AsH3) 0 – 0.2 ppm Boron Trichloride (BCl3) 0 – 15.0 ppm Carbon Dioxide (CO2) 0 – 1.0 % Carbon Monoxide (CO) 0 – 300 ppm Chlorine (Cl2) 0 – 3.0 ppm Chlorine Dioxide (ClO2) 0 – 1.0 ppm Chlorine Trifluoride (CIF3) 0 – 1.0 ppm Combustibles 0 – 100% LEL Diborane (B2H6) 0 – 30.0 ppm Fluorine (F2) 0 – 5/15 ppm Hydrogen (H2) 0 – 2000 ppm Hydrogen Chloride (HCl) 0 – 15.0 ppm Hydrogen Fluoride (HF) 0 – 9.0 ppm Hydrogen Sulfide (H2S) 0 – 100.0 ppm Nitric Oxide (NO) 0 – 100.0 ppm Nitrogen Dioxide (NO2) 0 – 15.0 ppm Nitrogen Trifluoride (NF3) 0 – 30.0 ppm Oxygen (O2) 0 – 25.0% Ozone (O3) 0 – 1.0 ppm Phosphine (PH3) 0 – 1.0 ppm Silane (SiH4) 0 – 15.0 ppm Sulphur Dioxide (SO2) 0 – 30.0 ppm TEOS (Si(OC2H5)4) 0 – 15/30 ppm - Downloads
-