Sensitron Smart 3-R  Refrigerant Sensor

Smart 3-R Refrigerant Sensor  

Features

• Self-diagnostic procedures to control the hardware and sensor correct operation.

• Zero follower to maintain the detector zero point, from possible drifts caused by thermal or physical variations of the transducer.

• Digital filter, employed in the digital analysis of the analog values sampled, this filter corrects temporary phenomena from causing reading errors or false alarms.

• Hysteresis cycle: applied to the outputs associated to the alarm thresholds, it prevents continuous output switching when close to the threshold values.

• The SMART3-R detectors offer a fast and failsafe installation as well as an easy maintenance and calibration routine via the handheld keypad STS/CKD.

Applications

  • Industrial
  • Machinery
  • Refrigerant

Sensitron Smart 3-R Refrigerant Sensor Overview

The SMART3-R (with LED indication) gas detectors, Refrigerant Sensor, are ideal for non-classified areas. They employ high-quality catalytic, MOS, electrochemical, or infrared sensors, which provide excellent linearity and accuracy, with an estimated lifetime of 4 years for infrared or pellistors sensors and 2 years for electrochemical cell sensors. The SMART3-R gas detectors provide a proportional 4-20mA output signal. By employing optional boards, they can either communicate over a serial RS-485 bus or provide relay outputs. In detail, the available outputs are as follows:

• 4-20 mA. Proportional 4-20mA output current corresponding to the full range (LEL or ppm).

• Relay. By adding the STS3REL board, the unit is provided with 3 relays with voltage-free changeover contacts. One relay is dedicated to the fault and watchdog, while the remaining two relays can be associated with two out of the three available alarm thresholds.

• Serial RS485. By adding the STS.IDI interface, the detector can communicate on the RS-485 bus with MULTISCAN+ + gas control panels.

Sensitron Smart 3-R Refrigerant Sensor Specifications

Typical use Detectors for use with Sensitron control panels to detect refrigerant gases. To be used in non-classified areas only.
Power supply

 

12-24 Vdc (-20% +15%)

 

Proportional output 4-20 mA

 

Detectable gases Halogenated refrigerant and mixtures

 

Ammonia (flammable LFL)

 

Ammonia (toxic ppm)

 

SF6

 

Sensing element employed

 

Infrared sensor or MOS

 

Catalytic sensor

 

Electroch. Cell or MOS

 

Infrared sensor

 

Range

 

0-2000 ppm 0-100% LFL (A2L) 0-100 ppm (F-gas)

 

0-100% LEL

 

0-100 ppm 0-200 ppm 0-1000 ppm

 

0-2000 ppm

 

Repeatability

 

5% FS

 

Operating temperature

 

-40 / + 60 °C (-30 / + 50 °C for ammonia EC)

 

Relative humidity

 

20-90 % non-condensing RH/40°C

 

IP rating

 

IP54

 

Compliances

 

EN 378-3 :2016 and F-Gas EC 517 :2014 EN 14624 :2012

 

Overview

Sensitron Smart 3-R Refrigerant Sensor Overview

The SMART3-R (with LED indication) gas detectors, Refrigerant Sensor, are ideal for non-classified areas. They employ high-quality catalytic, MOS, electrochemical, or infrared sensors, which provide excellent linearity and accuracy, with an estimated lifetime of 4 years for infrared or pellistors sensors and 2 years for electrochemical cell sensors. The SMART3-R gas detectors provide a proportional 4-20mA output signal. By employing optional boards, they can either communicate over a serial RS-485 bus or provide relay outputs. In detail, the available outputs are as follows:

• 4-20 mA. Proportional 4-20mA output current corresponding to the full range (LEL or ppm).

• Relay. By adding the STS3REL board, the unit is provided with 3 relays with voltage-free changeover contacts. One relay is dedicated to the fault and watchdog, while the remaining two relays can be associated with two out of the three available alarm thresholds.

• Serial RS485. By adding the STS.IDI interface, the detector can communicate on the RS-485 bus with MULTISCAN+ + gas control panels.

Specifications

Sensitron Smart 3-R Refrigerant Sensor Specifications

Typical use Detectors for use with Sensitron control panels to detect refrigerant gases. To be used in non-classified areas only.
Power supply

 

12-24 Vdc (-20% +15%)

 

Proportional output 4-20 mA

 

Detectable gases Halogenated refrigerant and mixtures

 

Ammonia (flammable LFL)

 

Ammonia (toxic ppm)

 

SF6

 

Sensing element employed

 

Infrared sensor or MOS

 

Catalytic sensor

 

Electroch. Cell or MOS

 

Infrared sensor

 

Range

 

0-2000 ppm 0-100% LFL (A2L) 0-100 ppm (F-gas)

 

0-100% LEL

 

0-100 ppm 0-200 ppm 0-1000 ppm

 

0-2000 ppm

 

Repeatability

 

5% FS

 

Operating temperature

 

-40 / + 60 °C (-30 / + 50 °C for ammonia EC)

 

Relative humidity

 

20-90 % non-condensing RH/40°C

 

IP rating

 

IP54

 

Compliances

 

EN 378-3 :2016 and F-Gas EC 517 :2014 EN 14624 :2012

 