Combustible Gas Detector – KR61-0203-02RKTR

KR61-0203-02RKTR Combustible gas detector

Features:

  • Long life of 3 to 5 years
  • Increased stability
  • Retro fits all existing installations
  • New duct mount feature
  • Compatible with Beacon controllers
  • SAA Approved
  • 3-Wire

Application/s:

  • Petrochemical plants
  • Power stations
  • Telephone exchanges
  • Boiler rooms
  • Refineries Aerosol manufacturers
  • Paint manufacturers
  • Mining

Overview:

The Combustible gas detector configuration consist of a 3-wire sensor, amplifier and enclosure with terminal strips. The combustible gas sensor type KR61-0203-02RKTR, for diffusion sensing, is a highly reliable catalytic style sensor which is designed to give extended service even under extreme conditions. The combination palladium/platinum catalyst resists destruction by combustible gas levels above 100% LEL, lead and sulphur compounds.

The sensor is enclosed in a 316 stainless steel shell and 316 sintered stainless steel flame arrestor, which is teflon coated. The stainless steel ensures high corrosion resistance, and the teflon covering on the flame arrestor resists the accumulation of dirt and dust. However, it should be realised that the sensor elements themselves are susceptible to breakage by shock and therefore the sensor should not be roughly handled prior to its installation. The enclosure is SAA approved and is rated Class I, IP 66, Zones 1 and 2. This combination makes the KR61-0203-02RKTR a robust product which can be used in various applications.

The amplifier board has a 24 VDC input and a 4-20mA output, which enables easy connection to any PLC, Scada or BMS system. It can be directly mounted onto the Beacon 200 or Beacon 800 Controller. The Beacon can be directly wired to a variety of devices like alarm horns, buzzers, or lights. With 10 amp rated relays, it eliminates the need for costly external relays from the controller to devices.

Specifications:

Detection method Catalytic Combustion
Measuring range 0 – 100% LEL
Sampling method Continuous Diffusion
Max distance 30 metres from Amp
Repeatability + 2% of full scale
Linearity + 5% – over 80% LEL
Response time Less than 15 sec to 90% of gas applied
Temperature range -45°C to 80°C
Service information 6 monthly Service & Calibration
Humidity range Below 95% R.H. (non-condensing)
Cable Entry 20 mm Metric
Connections 3 wire shielded 1.5 mm
Junction box IP 66, AUS Ex 319
Input 24 VDC
Output 4 – 20 mA
Operating Current 385 mA for Methane, 345 mA for other
Sensor Certification ANZEx 09.3003U-2

Downloads

Specifications:

 

Certification

Overview

Overview:

The Combustible gas detector configuration consist of a 3-wire sensor, amplifier and enclosure with terminal strips. The combustible gas sensor type KR61-0203-02RKTR, for diffusion sensing, is a highly reliable catalytic style sensor which is designed to give extended service even under extreme conditions. The combination palladium/platinum catalyst resists destruction by combustible gas levels above 100% LEL, lead and sulphur compounds.

The sensor is enclosed in a 316 stainless steel shell and 316 sintered stainless steel flame arrestor, which is teflon coated. The stainless steel ensures high corrosion resistance, and the teflon covering on the flame arrestor resists the accumulation of dirt and dust. However, it should be realised that the sensor elements themselves are susceptible to breakage by shock and therefore the sensor should not be roughly handled prior to its installation. The enclosure is SAA approved and is rated Class I, IP 66, Zones 1 and 2. This combination makes the KR61-0203-02RKTR a robust product which can be used in various applications.

The amplifier board has a 24 VDC input and a 4-20mA output, which enables easy connection to any PLC, Scada or BMS system. It can be directly mounted onto the Beacon 200 or Beacon 800 Controller. The Beacon can be directly wired to a variety of devices like alarm horns, buzzers, or lights. With 10 amp rated relays, it eliminates the need for costly external relays from the controller to devices.

Specifications

Specifications:

Detection method Catalytic Combustion
Measuring range 0 – 100% LEL
Sampling method Continuous Diffusion
Max distance 30 metres from Amp
Repeatability + 2% of full scale
Linearity + 5% – over 80% LEL
Response time Less than 15 sec to 90% of gas applied
Temperature range -45°C to 80°C
Service information 6 monthly Service & Calibration
Humidity range Below 95% R.H. (non-condensing)
Cable Entry 20 mm Metric
Connections 3 wire shielded 1.5 mm
Junction box IP 66, AUS Ex 319
Input 24 VDC
Output 4 – 20 mA
Operating Current 385 mA for Methane, 345 mA for other
Sensor Certification ANZEx 09.3003U-2