R65-2424RK-C Hydrogen Sulphide Gas Detector

Hydrogen Sulphide Gas Detector - R65-2424RK-C

Features

  • Water/dust resistant housing
  • Sensor and Amplifier
  • Long life sensors (2+ years typical)
  • Competitively priced
  • Compact design

Applications

  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Loading Docks

Hydrogen Sulphide Gas Detector Overview

This highly reliable, cost-effective Hydrogen Sulphide Gas Detector amplifier and enclosure is designed to fit into any current controller or BMS system.  Used primarily in the wastewater treatment industry, the H2S sensor has proven itself to be a robust unit that stands up to any environment. The compact design and water- and dust-resistant housing ensure that not only are its sensors long-lasting, but the enclosure is as well. The electronics are protected inside an aluminium cast enclosure to avoid damage from mechanical abuse, water, dust or corrosion. Sensors for H2S are long-lasting and typically last 2–3 years.

The transmitter operates from 24 VDC (18VDC to 30 VDC), and provides a 4-20 mA signal. This allows the sensor to be connected directly to the Beacon controller series. The hydrogen sulphide transmitter can be used indoors or outdoors.

Hydrogen Sulphide Gas Detector Specifications

Sensor Type Sensor Type
Measuring range Measuring range
Resolution 1ppm
Linearity + 5% F.S.
Response time Less than 60 sec to 90% of gas applied
Life Expectancy 3 to 5 Years normal service
Dimensions 150mm (L) x 64mm (H) x 82mm (W)
Temperature range -10°C to 50°C
Humidity range 0% to 95% non-condensing
Connections 2 Core, shielded, 1.5 mm
Operating Voltage 18 to 30 VDC
Output 4 – 20mA
Maximum Current Draw 24mA (2-wire system)
Enclosure IP66, Polycarb
Overview

Hydrogen Sulphide Gas Detector Overview

This highly reliable, cost-effective Hydrogen Sulphide Gas Detector amplifier and enclosure is designed to fit into any current controller or BMS system.  Used primarily in the wastewater treatment industry, the H2S sensor has proven itself to be a robust unit that stands up to any environment. The compact design and water- and dust-resistant housing ensure that not only are its sensors long-lasting, but the enclosure is as well. The electronics are protected inside an aluminium cast enclosure to avoid damage from mechanical abuse, water, dust or corrosion. Sensors for H2S are long-lasting and typically last 2–3 years.

The transmitter operates from 24 VDC (18VDC to 30 VDC), and provides a 4-20 mA signal. This allows the sensor to be connected directly to the Beacon controller series. The hydrogen sulphide transmitter can be used indoors or outdoors.

Specifications

Hydrogen Sulphide Gas Detector Specifications

Sensor Type Sensor Type
Measuring range Measuring range
Resolution 1ppm
Linearity + 5% F.S.
Response time Less than 60 sec to 90% of gas applied
Life Expectancy 3 to 5 Years normal service
Dimensions 150mm (L) x 64mm (H) x 82mm (W)
Temperature range -10°C to 50°C
Humidity range 0% to 95% non-condensing
Connections 2 Core, shielded, 1.5 mm
Operating Voltage 18 to 30 VDC
Output 4 – 20mA
Maximum Current Draw 24mA (2-wire system)
Enclosure IP66, Polycarb
Downloads

Enquire Now

Please provide a contact email and/or phone number: