Sensitron Smart 3-R  Refrigerant Sensor

Smart 3-R Refrigerant Sensor  

Features

Self-diagnostic procedures to control the hardware and sensor correct operation.

Zero follower to maintain the detector zero point, from possible drifts caused by thermal or physical variations of the transducer.

Digital filter, employed in the digital analysis of the analog values sampled, this filter corrects temporary phenomena from causing reading errors or false alarms.

Hysteresis cycle: applied to the outputs associated to the alarm thresholds, it prevents continuous output switching when close to the threshold values.

• The SMART3-R detectors offer a fast and failsafe installation as well as an easy maintenance and calibration routine via the handheld keypad STS/CKD.

Applications

  • Industrial
  • Machinery
  • Refrigerant

Sensitron Smart 3-R Refrigerant Sensor Overview

The SMART3-R (with LED indication) gas detectors, Refrigerant Sensor, are ideal for non-classified areas. They employ high-quality catalytic, MOS, electrochemical, or infrared sensors, which provide excellent linearity and accuracy, with an estimated lifetime of 4 years for infrared or pellistors sensors and 2 years for electrochemical cell sensors. The SMART3-R gas detectors provide a proportional 4-20mA output signal. By employing optional boards, they can either communicate over a serial RS-485 bus or provide relay outputs. In detail, the available outputs are as follows:

• 4-20 mA. Proportional 4-20mA output current corresponding to the full range (LEL or ppm).

• Relay. By adding the STS3REL board, the unit is provided with 3 relays with voltage-free changeover contacts. One relay is dedicated to the fault and watchdog, while the remaining two relays can be associated with two out of the three available alarm thresholds.

• Serial RS485. By adding the STS.IDI interface, the detector can communicate on the RS-485 bus with MULTISCAN+ + gas control panels.

Sensitron Smart 3-R Refrigerant Sensor Specifications

Typical use Detectors for use with Sensitron control panels to detect refrigerant gases. To be used in non-classified areas only.
Power supply

 

12-24 Vdc (-20% +15%)

 

Proportional output 4-20 mA

 

Detectable gases Halogenated refrigerant and mixtures

 

Ammonia (flammable LFL)

 

Ammonia (toxic ppm)

 

SF6

 

Sensing element employed

 

Infrared sensor or MOS

 

Catalytic sensor

 

Electroch. Cell or MOS

 

Infrared sensor

 

Range

 

0-2000 ppm 0-100% LFL (A2L) 0-100 ppm (F-gas)

 

0-100% LEL

 

0-100 ppm 0-200 ppm 0-1000 ppm

 

0-2000 ppm

 

Repeatability

 

5% FS

 

Operating temperature

 

-40 / + 60 °C (-30 / + 50 °C for ammonia EC)

 

Relative humidity

 

20-90 % non-condensing RH/40°C

 

IP rating

 

IP54

 

Compliances

 

EN 378-3 :2016 and F-Gas EC 517 :2014 EN 14624 :2012

 

Overview

Sensitron Smart 3-R Refrigerant Sensor Overview

The SMART3-R (with LED indication) gas detectors, Refrigerant Sensor, are ideal for non-classified areas. They employ high-quality catalytic, MOS, electrochemical, or infrared sensors, which provide excellent linearity and accuracy, with an estimated lifetime of 4 years for infrared or pellistors sensors and 2 years for electrochemical cell sensors. The SMART3-R gas detectors provide a proportional 4-20mA output signal. By employing optional boards, they can either communicate over a serial RS-485 bus or provide relay outputs. In detail, the available outputs are as follows:

• 4-20 mA. Proportional 4-20mA output current corresponding to the full range (LEL or ppm).

• Relay. By adding the STS3REL board, the unit is provided with 3 relays with voltage-free changeover contacts. One relay is dedicated to the fault and watchdog, while the remaining two relays can be associated with two out of the three available alarm thresholds.

• Serial RS485. By adding the STS.IDI interface, the detector can communicate on the RS-485 bus with MULTISCAN+ + gas control panels.

Specifications

Sensitron Smart 3-R Refrigerant Sensor Specifications

Typical use Detectors for use with Sensitron control panels to detect refrigerant gases. To be used in non-classified areas only.
Power supply

 

12-24 Vdc (-20% +15%)

 

Proportional output 4-20 mA

 

Detectable gases Halogenated refrigerant and mixtures

 

Ammonia (flammable LFL)

 

Ammonia (toxic ppm)

 

SF6

 

Sensing element employed

 

Infrared sensor or MOS

 

Catalytic sensor

 

Electroch. Cell or MOS

 

Infrared sensor

 

Range

 

0-2000 ppm 0-100% LFL (A2L) 0-100 ppm (F-gas)

 

0-100% LEL

 

0-100 ppm 0-200 ppm 0-1000 ppm

 

0-2000 ppm

 

Repeatability

 

5% FS

 

Operating temperature

 

-40 / + 60 °C (-30 / + 50 °C for ammonia EC)

 

Relative humidity

 

20-90 % non-condensing RH/40°C

 

IP rating

 

IP54

 

Compliances

 

EN 378-3 :2016 and F-Gas EC 517 :2014 EN 14624 :2012

 