RI-6000 Stand-Alone Carbon Dioxide Gas Monitor

The Stand Alone Carbon Dioxide Gas Monitor RI-600 measures carbon dioxide in the air. The RI-600 displays the measured carbon dioxide concentration on the LCD. If a high level of CO2 is present, the user is notified by an audible alarm tone and the multicoloured LCD digital display.

RI-600 Stand Alone Carbon Dioxide Gas Monitor

Features

  • Operates with or without a controller
  • Tri-colour visual alarm display: Green=Normal, Yellow=Alarm 1, Red=Alarm 2
  • Large easy to read digital display
  • Operates on 24 VDC
  • Remote mount sensor cable available
  • Compact wall mount design

Applications

  • Brewery
  • Restaurant
  • Office Room
  • Conference
  • Greenhouse
  • Classroom
  • Underground car park

RI-600 Stand-Alone Carbon Dioxide Gas Monitor Overview

The model RI-600 is an indoor, stand-alone monitor that detects Carbon Dioxide (CO2). It has multiple ranges up to 10000 ppm and can also be purchased in vol%. Its sleek, low-profile design features a unique tri-colour display. When Carbon Dioxide levels reach each alarm level, it changes colour. Also, it can operate on two power options: 24 VDC or alkaline batteries. The RI-600 has two preset alarms and comes ready to operate with a simple wall mount bracket. If Carbon Dioxide is present, the user is notified by an audible alarm tone and the multicoloured LED digital display.

The CO2 Monitor uses a Non-Dispersive Infrared Ray (NDIR) sensor. This long-life sensor is field-replaceable with no special tools required. Additionally, the sensor can also be remotely mounted with an optional remote sensor cable. This device is designed to replace large, bulky monitors and is intended for monitoring small areas.

Additional alarms and strobes may be integrated into the monitor. Furthermore, it can also be wired into a BMS (building management system), if required.

RI-600 Stand-Alone Carbon Dioxide Gas Monitor Specifications

Detection Principle Non-Dispersive Infrared (NDIR)
Gas Detected Carbon dioxide
Detection Range 0-2,000ppm, 0-5,000ppm, 0-10,000ppm

0-2vol%, 0-5vol%

Display Resolution 0~2,000ppm:1ppm

2,000ppm~10,000ppm: 10ppm 0~2vol%:0.005vol% 2~5vol%:0.010vol%

Detection method Diffusion type
Alarm setpoint value (Standard Setting) ppm range:1st 1,000ppm / 2nd 1000ppm

0~2vol%:1st 1.0vol% / 2nd 1.0vol% 0~5vol%:1st 2.5vol% / 2nd 2.5vol%

Accuracy Within ±5% for full scale

(to the gas concentration signal output) *Under the same test conditions

Response time 90% response (T90) within 60 seconds *Under the same test

conditions

Gas alarm type Two-step alarm (H-HH)
Gas alarm display Buzzer / flashing of red error message
Gas alarm pattern Auto-reset
Gas alarm contact No-voltage contact 1a or 1b and normally de-energized

(energized in response to an alarm)

Trouble Alarm /

Self-Diagnoseis

System abnormalities/sensor connection abnormalities
Display of Trouble Alarm Alarm detail display and backlight blinking

(orange), buzzer

Fault alarm pattern Auto-reset
Contact capacity 125 VAC – 1A or 30 VDC – 1 A

(resistance load)0 VAC ±10% (50/60 Hz) or, 24 VDC ±10%

Transmission Specification 4~20 mA DC
Power supply 100 VAC ±10% (50/60 Hz) or, 24 VDC ±10%
Power Consumption AC specification: Max. 6VA DC specification: Max. 4W
Initial clear Approx. 25 seconds
Warm-up time Approx. 30 minutes
Operating Temperature 0~40ºC (At a constant conditions)
Operating Humidity Below 90%RH (Non-condensing)
Structure Wall mounting type
Dimension Approx. 80 (W) x 120 (H) x 35.5 (D) mm
Weight AC specification: Approx. 200g

DC specification: Approx. 180g

Videos:

Stand Alone Carbon Dioxide Gas Monitor | RI-600

Overview

RI-600 Stand-Alone Carbon Dioxide Gas Monitor Overview

The model RI-600 is an indoor, stand-alone monitor that detects Carbon Dioxide (CO2). It has multiple ranges up to 10000 ppm and can also be purchased in vol%. Its sleek, low-profile design features a unique tri-colour display. When Carbon Dioxide levels reach each alarm level, it changes colour. Also, it can operate on two power options: 24 VDC or alkaline batteries. The RI-600 has two preset alarms and comes ready to operate with a simple wall mount bracket. If Carbon Dioxide is present, the user is notified by an audible alarm tone and the multicoloured LED digital display.

The CO2 Monitor uses a Non-Dispersive Infrared Ray (NDIR) sensor. This long-life sensor is field-replaceable with no special tools required. Additionally, the sensor can also be remotely mounted with an optional remote sensor cable. This device is designed to replace large, bulky monitors and is intended for monitoring small areas.

Additional alarms and strobes may be integrated into the monitor. Furthermore, it can also be wired into a BMS (building management system), if required.

Specifications

RI-600 Stand-Alone Carbon Dioxide Gas Monitor Specifications

Detection Principle Non-Dispersive Infrared (NDIR)
Gas Detected Carbon dioxide
Detection Range 0-2,000ppm, 0-5,000ppm, 0-10,000ppm

0-2vol%, 0-5vol%

Display Resolution 0~2,000ppm:1ppm

2,000ppm~10,000ppm: 10ppm 0~2vol%:0.005vol% 2~5vol%:0.010vol%

Detection method Diffusion type
Alarm setpoint value (Standard Setting) ppm range:1st 1,000ppm / 2nd 1000ppm

0~2vol%:1st 1.0vol% / 2nd 1.0vol% 0~5vol%:1st 2.5vol% / 2nd 2.5vol%

Accuracy Within ±5% for full scale

(to the gas concentration signal output) *Under the same test conditions

Response time 90% response (T90) within 60 seconds *Under the same test

conditions

Gas alarm type Two-step alarm (H-HH)
Gas alarm display Buzzer / flashing of red error message
Gas alarm pattern Auto-reset
Gas alarm contact No-voltage contact 1a or 1b and normally de-energized

(energized in response to an alarm)

Trouble Alarm /

Self-Diagnoseis

System abnormalities/sensor connection abnormalities
Display of Trouble Alarm Alarm detail display and backlight blinking

(orange), buzzer

Fault alarm pattern Auto-reset
Contact capacity 125 VAC – 1A or 30 VDC – 1 A

(resistance load)0 VAC ±10% (50/60 Hz) or, 24 VDC ±10%

Transmission Specification 4~20 mA DC
Power supply 100 VAC ±10% (50/60 Hz) or, 24 VDC ±10%
Power Consumption AC specification: Max. 6VA DC specification: Max. 4W
Initial clear Approx. 25 seconds
Warm-up time Approx. 30 minutes
Operating Temperature 0~40ºC (At a constant conditions)
Operating Humidity Below 90%RH (Non-condensing)
Structure Wall mounting type
Dimension Approx. 80 (W) x 120 (H) x 35.5 (D) mm
Weight AC specification: Approx. 200g

DC specification: Approx. 180g

Downloads
Videos

Videos:

Stand Alone Carbon Dioxide Gas Monitor | RI-600

Enquire Now

Please provide a contact email and/or phone number: