Features:
• Uses an optical interferometric sensor with high reliability and backed with an 80-year track record
• Gas analyser with refinements made to the optical interferometric sensor developed when our company was founded
• Sensor with no degradation in sensitivity and excellent long-term stability means replacement is not required for 10 years
• Takes measurements using gas-specific refractive indices, making it capable of measuring a wide range of gases
• Capable of detecting corrosive gases like methylene chloride, NH3 and VCM gases
• Flameproof enclosure (ATEX/IECEx/Japan Ex) that can even be used in H2 environment
• Comprehensive self-diagnostic function, and checks of gas concentrations as well as status using MODBUS communications
• Ideal for preventing explosions and monitoring concentrations of VOCs, and monitoring concentrations of hydrogen gas
Application/s:
• Petroleum Refining
• Petrochemicals
• Hydrogen Production
• Foodstuff e.g. breweries)
• Painting (e.g. automobile)
• Gravure Painting
Overview:
The FI-900 is equipped with Long-term Stability Optical Interferometric Sensor, ideal for controlling gas concentrations in Manufacturing Processes. Uses an optical interferometric sensor with high reliability and backed with an 80-year track record. Capable of detecting corrosive gases like methylene chloride, NH3 and VCM gases. The FI-900 has a flameproof enclosure (ATEX/IECEx/Japan Ex) that can even be used in H2 environment. Comprehensive self-diagnostic function, and checks of gas concentrations as well as status using MODBUS communications. Ideal for preventing explosions and monitoring concentrations of VOCs, and monitoring concentrations of hydrogen gas.
Certification
ATEX (Equipment for explosive atmospheres) explosion-proof certified product. IECEx (IEC System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres) certified product. TIIS (Technology Institution of Industrial Safety) explosion-proof certified product. CE Marking conforming product.
Specifications:
Model | FI-900 |
Measuring principle | Optical interferometric method |
Measuring gas | Combustible gases, solvent vapors, inert gases |
Measuring range | Depending on gas specifications |
Alarm setpoint | Depending on gas specifications |
Measurement accuracy | F.S. within ±3% (under same conditions) |
Response time | T90: within 30 seconds |
Measurement method | Specified flow gas feed from external sampling unit |
Display | Full-dot LCD (with backlight) |
External output | 4-20 mA DC (insulated, current throw type), permitted resistive load 300 Ω or less Minimum resolution 0.01 mA or less |
Communications output | RS-485 (MODBUS) communication function |
Alarm relay contact 1 | Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) |
Alarm relay contact 2 | Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) |
Malfunction contact | Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) |
Power supply | 24V DC±10% / 100 – 240V AC±10% 50/60Hz* The ATEX/IECEx specifications apply to DC power source only |
Power consumption | Max. 6 W (24 V DC±10%) / Max. 20 VA (100 – 240 V AC ±10% 50/60 Hz) *The ATEX/IECEx specifications apply to DC power source only |
Protection class | Equivalent to IP66/67 |
Operating temperature range | -20 to +60℃ _(ATEX/IECEx specifications) / -20 to +57°C (Japan Ex specifications) (no sudden changes) |
Operating humidity range | 0 to 95% RH (no condensation/use of condensible gases within unit) (no condensation) |
Operating pressure range | Atmospheric pressure or equivalent (no pulses) |
Outer dimensions | Approx. 286 (W) x 453 (H) x 150 (D) mm (projection portions excluded) |
Weight | Approx. 23 kg |
Explosion-proof structure | Flame-proof enclosures |
Explosion-proof class | Ⅱ2G Ex db ⅡB+H2 T4 Gb (ATEX) / Ex db ⅡB+H2 T4 Gb (IECEx) / Ex dⅡB+H2 T4 (Japan Ex) |
Self-diagnostic function | Status monitoring in 4 separate categories
・FAILURE ・FUNCTION CHECK ・MAINTENANCE REQUIRED ・OUT OF SPECIFICATION |
Accessories | Control key, Allen key (2 types), cable ground, plug |
- Overview
-
Overview:
The FI-900 is equipped with Long-term Stability Optical Interferometric Sensor, ideal for controlling gas concentrations in Manufacturing Processes. Uses an optical interferometric sensor with high reliability and backed with an 80-year track record. Capable of detecting corrosive gases like methylene chloride, NH3 and VCM gases. The FI-900 has a flameproof enclosure (ATEX/IECEx/Japan Ex) that can even be used in H2 environment. Comprehensive self-diagnostic function, and checks of gas concentrations as well as status using MODBUS communications. Ideal for preventing explosions and monitoring concentrations of VOCs, and monitoring concentrations of hydrogen gas.
Certification
ATEX (Equipment for explosive atmospheres) explosion-proof certified product. IECEx (IEC System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres) certified product. TIIS (Technology Institution of Industrial Safety) explosion-proof certified product. CE Marking conforming product.
- Specifications
-
Specifications:
Model FI-900 Measuring principle Optical interferometric method Measuring gas Combustible gases, solvent vapors, inert gases Measuring range Depending on gas specifications Alarm setpoint Depending on gas specifications Measurement accuracy F.S. within ±3% (under same conditions) Response time T90: within 30 seconds Measurement method Specified flow gas feed from external sampling unit Display Full-dot LCD (with backlight) External output 4-20 mA DC (insulated, current throw type), permitted resistive load 300 Ω or less Minimum resolution 0.01 mA or less Communications output RS-485 (MODBUS) communication function Alarm relay contact 1 Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) Alarm relay contact 2 Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) Malfunction contact Non-voltage contact, contact capacity 1 A 30 V DC (resistive load) Power supply 24V DC±10% / 100 – 240V AC±10% 50/60Hz*
The ATEX/IECEx specifications apply to DC power source onlyPower consumption Max. 6 W (24 V DC±10%) / Max. 20 VA (100 – 240 V AC ±10% 50/60 Hz) *The ATEX/IECEx specifications apply to DC power source only Protection class Equivalent to IP66/67 Operating temperature range -20 to +60℃ _(ATEX/IECEx specifications) / -20 to +57°C (Japan Ex specifications) (no sudden changes) Operating humidity range 0 to 95% RH (no condensation/use of condensible gases within unit) (no condensation) Operating pressure range Atmospheric pressure or equivalent (no pulses) Outer dimensions Approx. 286 (W) x 453 (H) x 150 (D) mm (projection portions excluded) Weight Approx. 23 kg Explosion-proof structure Flame-proof enclosures Explosion-proof class Ⅱ2G Ex db ⅡB+H2 T4 Gb (ATEX) / Ex db ⅡB+H2 T4 Gb (IECEx) / Ex dⅡB+H2 T4 (Japan Ex) Self-diagnostic function Status monitoring in 4 separate categories ・FAILURE ・FUNCTION CHECK ・MAINTENANCE REQUIRED ・OUT OF SPECIFICATION
Accessories Control key, Allen key (2 types), cable ground, plug - Downloads
-