FP-31 Portable Formaldehyde Gas Detector

FP-31 Portable Formaldehyde Gas Detector

Features

  • Easy to read LCD display
  • Easy operation
  • Self diagnosis
  • Less interference with other gases
  • Measures 0.005 pm
  • No warm-up time
  • Available download to PC
  • Resolutions 0.005 ppm
  • Read-out of sample in 30 minutes

Applications

  • Furniture and woodworking
  • Coating and varnishing
  • Engineered wood products
  • Medical/veterinary
  • Painting & corrosion-resistant finishes
  • Carpet manufacture & storage
  • Adhesives
  • Heat treatment options
  • Mortuary

FP-31 Portable Formaldehyde Gas Detector Overview

The portable formaldehyde gas detector model FP-31 is a precision gas analyser that measures gases in the ppm range using the photoelectric photometry method with chlorimetric detection tabs. This device is a highly sensitive portable instrument with an easy-to-read LCD display. The unit can detect very low levels of formaldehyde to confirm whether an area has safe breathing levels. There are no known interfering gases, as shown on the chart on the reverse side of this sheet.

Inbuilt Microprocessor

The built-in microprocessor-controlled sample pump of the FP-31 draws the sample over the tab, providing a direct digital readout. The inbuilt data logger will store up to 99 readings that can be viewed on the display or downloaded onto a PC. The FP-31 is designed to monitor formaldehyde at levels below the World Health Organisation level of 0.08 ppm (based on an average reading over 30 minutes, with a resolution of 0.005 ppm). There are two ranges available for this model.

Detection

The portable formaldehyde gas detector FP-31 uses a photoelectric photometry method that utilises colourimetric tablets for detection. A tablet is placed into the instrument, and then a room air sample is pumped onto the tablet for either 15 or 30 minutes. If formaldehyde is present, it will cause the chemically impregnated tablet surface to darken or stain.

The Stain

The magnitude of the stain directly correlates to the level of formaldehyde in the air. The darkness of the stain is measured by an optical sensor in the portable formaldehyde gas detector model FP-31, and the instrument then calculates the formaldehyde concentration. The portable formaldehyde gas detector model FP-31 then has a direct readout of the formaldehyde measurement on an easy-to-read LCD display. The unit can detect very low levels of formaldehyde to confirm whether an area has safe breathing levels. There are no known interfering gases, as shown on the chart on the reverse side of this sheet.

FP-31 Portable Formaldehyde Gas Detector Specifications

Detection gas Formaldehyde (HCHO) in air
Detection range TAB No.008

0‐0.4 ppm

Tab No.009

0‐1.00 ppm

Detection Time 30 min. (1,800 sec) 15 min. (900 sec)
Resolution 0‐005 ppm 0.01 ppm
Detection principle Photoelectric Photometry method
Detection method Colorimetric tablet method (Accumulating measurement)
Display Digital LCD
Sampling method Sample drawing with built‐in pump
Operating conditions ‐10°C +40°C, below 90%RH (non‐condensing)
Memory Detection point: Up to 99 points (automatic recording at completion of measurement)
SelfDiagnosis Sensor failure, Pump failure, Battery error, System failure
Power Source AA size Alkaline batteries (4pcs)
Continuous operating time Approx 12 hours (with no alarm or backlight, with alkaline battery at 20°C)
Dimensions Approx 8cm (W) x 15cm (H) x 4cm (D)
Weight Approx 250g without dry‐cell battery
Standard Accessories Detection TAB (20 pcs/pack)

Detection TAB (20 pcs/pack)

AA size Alkaline batteries

Attachment for tripod stand

Operating Manual

Inspection certificate

Optional Accessories Data logger software

Filter

 

Interference against other gases (typical)

Test Gas Concentration Reading
Toluene 1.0% vol 0 ppm
Benzene 1.0% vol 0 ppm
Acetoaldehyde 100 ppm 0 ppm
Carbon Monoxide 50 ppm 0 ppm
Carbon Dioxide 1.0% vol 0 ppm
Ammonia 25 ppm 0 ppm
Acetone 1.0% vol 0 ppm
Overview

FP-31 Portable Formaldehyde Gas Detector Overview

The portable formaldehyde gas detector model FP-31 is a precision gas analyser that measures gases in the ppm range using the photoelectric photometry method with chlorimetric detection tabs. This device is a highly sensitive portable instrument with an easy-to-read LCD display. The unit can detect very low levels of formaldehyde to confirm whether an area has safe breathing levels. There are no known interfering gases, as shown on the chart on the reverse side of this sheet.

Inbuilt Microprocessor

The built-in microprocessor-controlled sample pump of the FP-31 draws the sample over the tab, providing a direct digital readout. The inbuilt data logger will store up to 99 readings that can be viewed on the display or downloaded onto a PC. The FP-31 is designed to monitor formaldehyde at levels below the World Health Organisation level of 0.08 ppm (based on an average reading over 30 minutes, with a resolution of 0.005 ppm). There are two ranges available for this model.

Detection

The portable formaldehyde gas detector FP-31 uses a photoelectric photometry method that utilises colourimetric tablets for detection. A tablet is placed into the instrument, and then a room air sample is pumped onto the tablet for either 15 or 30 minutes. If formaldehyde is present, it will cause the chemically impregnated tablet surface to darken or stain.

The Stain

The magnitude of the stain directly correlates to the level of formaldehyde in the air. The darkness of the stain is measured by an optical sensor in the portable formaldehyde gas detector model FP-31, and the instrument then calculates the formaldehyde concentration. The portable formaldehyde gas detector model FP-31 then has a direct readout of the formaldehyde measurement on an easy-to-read LCD display. The unit can detect very low levels of formaldehyde to confirm whether an area has safe breathing levels. There are no known interfering gases, as shown on the chart on the reverse side of this sheet.

Specifications

FP-31 Portable Formaldehyde Gas Detector Specifications

Detection gas Formaldehyde (HCHO) in air
Detection range TAB No.008

0‐0.4 ppm

Tab No.009

0‐1.00 ppm

Detection Time 30 min. (1,800 sec) 15 min. (900 sec)
Resolution 0‐005 ppm 0.01 ppm
Detection principle Photoelectric Photometry method
Detection method Colorimetric tablet method (Accumulating measurement)
Display Digital LCD
Sampling method Sample drawing with built‐in pump
Operating conditions ‐10°C +40°C, below 90%RH (non‐condensing)
Memory Detection point: Up to 99 points (automatic recording at completion of measurement)
SelfDiagnosis Sensor failure, Pump failure, Battery error, System failure
Power Source AA size Alkaline batteries (4pcs)
Continuous operating time Approx 12 hours (with no alarm or backlight, with alkaline battery at 20°C)
Dimensions Approx 8cm (W) x 15cm (H) x 4cm (D)
Weight Approx 250g without dry‐cell battery
Standard Accessories Detection TAB (20 pcs/pack)

Detection TAB (20 pcs/pack)

AA size Alkaline batteries

Attachment for tripod stand

Operating Manual

Inspection certificate

Optional Accessories Data logger software

Filter

 

Interference against other gases (typical)

Test Gas Concentration Reading
Toluene 1.0% vol 0 ppm
Benzene 1.0% vol 0 ppm
Acetoaldehyde 100 ppm 0 ppm
Carbon Monoxide 50 ppm 0 ppm
Carbon Dioxide 1.0% vol 0 ppm
Ammonia 25 ppm 0 ppm
Acetone 1.0% vol 0 ppm