Highly Accurate Infrared CO2 Gas Sensor – RI-215

Features:

  • Alarm contact output provided

  • Compact design

  • Easy to read LCD display

  • Simple installation

  • Low maintenance

  • Three detection ranges available: 2000ppm / 5000ppm / 9990ppm

Application/s:

  • HVAC

  • Food processing

  • Breweries

  • Greenhouses

  • Industrial plants

  • Laboratories

  • Computer rooms

  • Gas storage rooms

Overview:

The RI-215 series of infrared CO2 gas monitors are widely used in the measurement and control of CO2 levels in a variety of applications where CO2 monitoring or detection is required. A highly accurate, non-dispersive infrared absorption sensor is used to provide direct measurements through diffusion or sample draw monitors, and activate alarms or control ventilation systems based on preset CO2 levels. Each model provides a digital readout in parts per million of CO2 providing precise measurement and direct visual indication of gas levels. A 4-20 mA output is provided to send a signal to a fire panel or other PLC system and a relay is available to trip an alarm or activate a ventilation system.

Three levels of measurement are provided: 0-2,000 ppm (ASHRAE 1969 IAQ max PEL), 0-5,000 ppm (leak detection of CO2 storage tanks) 0-9,999 ppm, and 0-5%. The RI-215A runs on 24 VAC or 24 VDC and the RI-215D with sample drawing pump runs on 115 VAC or 220 VAC. Each are designed for indoor use only and supplied in a NEMA 12 enclosure that is easily accessible for calibration, service, and continuous monitoring. Control Equipment offers additional monitors with higher measurement levels in portable or fixed installation applications. Please contact us today for more information on other CO2 monitors available.

Specifications:

Model RI‐215A RI‐215D
Detection principle Non dispersive infrared absorption (NDIR)
Measuring gas Carbon dioxide (CO2) in air
Measuring range 0‐2000ppm, 0‐5000ppm, 0‐9990ppm Specify one of the ranges when ordering
Increment 1 ppm digit for 0‐2000ppm or 10 ppm digit for 2000ppm ‐ 9990ppm
Output signal Specify between 0‐10VDC linear (min. 500kΩ) and 4‐20mA linear (min. 300kΩ)
Power requirement & consumption 24VDC or
24VAC ± 10%, 4VA
240VAC ± 10%,
50/60Hz, 12VA
Outer dimensions (in mm) &

 

Approx 78 (W) x 78 (H) x 31mm (D) Approx 220 (W) x 200 (H) x 76mm (D)
Warming up time & operating 30 minutes for full warm up (display starts after 1 minute) / 0‐40°C, 10‐90% RH
Alarm range & contact 50ppm – Full scale (adjustable in steps of 10ppm) / 125VAC, 0.5A, dry contact

Downloads:

Specifications:

Overview

Overview:

The RI-215 series of infrared CO2 gas monitors are widely used in the measurement and control of CO2 levels in a variety of applications where CO2 monitoring or detection is required. A highly accurate, non-dispersive infrared absorption sensor is used to provide direct measurements through diffusion or sample draw monitors, and activate alarms or control ventilation systems based on preset CO2 levels. Each model provides a digital readout in parts per million of CO2 providing precise measurement and direct visual indication of gas levels. A 4-20 mA output is provided to send a signal to a fire panel or other PLC system and a relay is available to trip an alarm or activate a ventilation system.

Three levels of measurement are provided: 0-2,000 ppm (ASHRAE 1969 IAQ max PEL), 0-5,000 ppm (leak detection of CO2 storage tanks) 0-9,999 ppm, and 0-5%. The RI-215A runs on 24 VAC or 24 VDC and the RI-215D with sample drawing pump runs on 115 VAC or 220 VAC. Each are designed for indoor use only and supplied in a NEMA 12 enclosure that is easily accessible for calibration, service, and continuous monitoring. Control Equipment offers additional monitors with higher measurement levels in portable or fixed installation applications. Please contact us today for more information on other CO2 monitors available.

Specifications

Specifications:

Model RI‐215A RI‐215D
Detection principle Non dispersive infrared absorption (NDIR)
Measuring gas Carbon dioxide (CO2) in air
Measuring range 0‐2000ppm, 0‐5000ppm, 0‐9990ppm Specify one of the ranges when ordering
Increment 1 ppm digit for 0‐2000ppm or 10 ppm digit for 2000ppm ‐ 9990ppm
Output signal Specify between 0‐10VDC linear (min. 500kΩ) and 4‐20mA linear (min. 300kΩ)
Power requirement & consumption 24VDC or
24VAC ± 10%, 4VA
240VAC ± 10%,
50/60Hz, 12VA
Outer dimensions (in mm) &

 

Approx 78 (W) x 78 (H) x 31mm (D) Approx 220 (W) x 200 (H) x 76mm (D)
Warming up time & operating 30 minutes for full warm up (display starts after 1 minute) / 0‐40°C, 10‐90% RH
Alarm range & contact 50ppm – Full scale (adjustable in steps of 10ppm) / 125VAC, 0.5A, dry contact