GX-8000 Series Portable Single Gas Monitors (LEL & O2)

GX-8000 Portable single gas monitors

Features:

  • ATEX Exia II CT4 approved
  • Water and dust resistant IP-67
  • Loud alarm button with 95dB
  • Strong sample drawing capability (0.75L/min)
  • Digital display & digital bargraph
  • 3 bright LED alarm windows
  • Datalogging standard
  • Ergonomic design with waist strap for hands free operation (option)
  • Lithium-ion rechargeable battery (option)

Application/s:

  • Confined space
  • Refineries / petrochemical / chemical plants
  • Oil tanker / gas carrier / bulk carrier
  • Chemical tanker
  • Water / wastewater treatment
  • Fire services
  • Telecommunication services
  • Power plant
  • Gas plant / gas supplier services
  • Utilities

Overview of the portable single gas monitors:

There are two different models in the series, the GX-8000 portable single gas monitors (LEL & O2) detects the oxygen in the air or LEL which detects dangerous combustible gases like methane, isobutane and hydrogen.

LSD Display

The large, LCD display, shows a digital value of the component gas concentrations up to 5 by simultaneous display, and performs more reliability to confirm the concentration. In loud environments the high brightness LED lamps arranged in three directions alarms, the workers in a visible way.

IP rating

These portable single gas monitors (LEL & O2) features a waterproof and dustproof design with IP 67 rating for which the over-mould body is impact resistant and RFI shielded. Consequently, the GX-8000 portable single gas monitors (LEL & O2) offer full protection while minimising large fleets because of it’s functionality.

Specifications of the portable single gas monitors:

Target Gas

All Combustible gases
(CH4, i-C4H10, H2 and others)

 

Oxygen (O2)

 

Hydrogen Sulphide (H2S)

 

Carbon Monoxide (CO)

 

Detection Principle

Catalytic Combustion

Thermal conductivity

Galvanic cell

Electro-chemical cell

Electro-chemical cell

Detection Range (Increments)

 

0 – 100% LEL (1%LEL)

0 – 100% Vol (1Vol%)

0 – 40.0% Vol (0.1%)

0 – 100 ppm (0.5ppm)

0 – 500 ppm (1ppm)

Gas Alarm

 

1st alarm 5% LEL

2nd alarm 10% LEL

N/A

1st alarm: 19.5%

2nd alarm: 23.5%

1st alarm 10 ppm

2nd alarm 15 ppm

TWA alarm 10 ppm STEL alarm 15 ppm

1st alarm 30 ppm

2nd alarm 60 ppm

TWA alarm 30 ppm STEL alarm 200 ppm

Types of Alarms

Gas Alarm: Latching, 2 alarms Failure Alarm: Flow Failure, Sensor failure, Battery failure, Circuit failure, Calibration failure

Display of Alarms

 

Digital LCD: LED’s flash Buzzer: Buzzer sounds alternating between low and high pitch Visual Indication: Indication value flashes. Alarm message displays and flashes.

Alarm Sound

Greater than 35dB (A) at 30 cm

Display

Digital LCD with auto backlight

Digital display (7 Segments) and digital bar graph (25 segments)

Sampling Method

 

Sample draw, minimum 0.75L/minute

Power Source

 

Lithium-ion battery: Standard 3 hours for full charge

AA Alkaline battery (3 pieces): Optional

Continuous Operation

Lithium-ion battery: Greater than 12 hours

AA Alkaline battery: Greater than 6 hours

Operating Temp & Humidity

 

-20°C ~ to +50°C, below 95% RH, non-condensing

Dimension & Weight

 

Approx 15cm x 8cm x 13cm (L x W x H), approx 1.1kg

Ingress Proof Rating  Equivalent to IP67

 

Explosion Proof

Intrinsically safe Ex ia IIC/IIB T4 Ga

 

Approvals

IECEx, ATEX

 

Standard Accessories

Neck Shoulder Strap, Gas Sampling Hose (1m), Gas Sampling Probe,
AC Powered Charger, Instruction Manual, Lithium-ion battery unit

Additional Accessories

Complying to IEC60079-29-1
Indication to show energising (pilot indicator and pump driving indicator), Pump stop function, Bump test function, IrDA Communication, Data logger, Password Protected

Warranty

2 year material and workmanship

 

Downloads:

 

Specifications of the portable single gas monitors

 

Certification:

Videos:

GX-8000 Basic Training

Overview

Overview of the portable single gas monitors:

There are two different models in the series, the GX-8000 portable single gas monitors (LEL & O2) detects the oxygen in the air or LEL which detects dangerous combustible gases like methane, isobutane and hydrogen.

LSD Display

The large, LCD display, shows a digital value of the component gas concentrations up to 5 by simultaneous display, and performs more reliability to confirm the concentration. In loud environments the high brightness LED lamps arranged in three directions alarms, the workers in a visible way.

IP rating

These portable single gas monitors (LEL & O2) features a waterproof and dustproof design with IP 67 rating for which the over-mould body is impact resistant and RFI shielded. Consequently, the GX-8000 portable single gas monitors (LEL & O2) offer full protection while minimising large fleets because of it’s functionality.

Specifications

Specifications of the portable single gas monitors:

Target Gas

All Combustible gases
(CH4, i-C4H10, H2 and others)

 

Oxygen (O2)

 

Hydrogen Sulphide (H2S)

 

Carbon Monoxide (CO)

 

Detection Principle

Catalytic Combustion

Thermal conductivity

Galvanic cell

Electro-chemical cell

Electro-chemical cell

Detection Range (Increments)

 

0 – 100% LEL (1%LEL)

0 – 100% Vol (1Vol%)

0 – 40.0% Vol (0.1%)

0 – 100 ppm (0.5ppm)

0 – 500 ppm (1ppm)

Gas Alarm

 

1st alarm 5% LEL

2nd alarm 10% LEL

N/A

1st alarm: 19.5%

2nd alarm: 23.5%

1st alarm 10 ppm

2nd alarm 15 ppm

TWA alarm 10 ppm STEL alarm 15 ppm

1st alarm 30 ppm

2nd alarm 60 ppm

TWA alarm 30 ppm STEL alarm 200 ppm

Types of Alarms

Gas Alarm: Latching, 2 alarms Failure Alarm: Flow Failure, Sensor failure, Battery failure, Circuit failure, Calibration failure

Display of Alarms

 

Digital LCD: LED’s flash Buzzer: Buzzer sounds alternating between low and high pitch Visual Indication: Indication value flashes. Alarm message displays and flashes.

Alarm Sound

Greater than 35dB (A) at 30 cm

Display

Digital LCD with auto backlight

Digital display (7 Segments) and digital bar graph (25 segments)

Sampling Method

 

Sample draw, minimum 0.75L/minute

Power Source

 

Lithium-ion battery: Standard 3 hours for full charge

AA Alkaline battery (3 pieces): Optional

Continuous Operation

Lithium-ion battery: Greater than 12 hours

AA Alkaline battery: Greater than 6 hours

Operating Temp & Humidity

 

-20°C ~ to +50°C, below 95% RH, non-condensing

Dimension & Weight

 

Approx 15cm x 8cm x 13cm (L x W x H), approx 1.1kg

Ingress Proof Rating  Equivalent to IP67

 

Explosion Proof

Intrinsically safe Ex ia IIC/IIB T4 Ga

 

Approvals

IECEx, ATEX

 

Standard Accessories

Neck Shoulder Strap, Gas Sampling Hose (1m), Gas Sampling Probe,
AC Powered Charger, Instruction Manual, Lithium-ion battery unit

Additional Accessories

Complying to IEC60079-29-1
Indication to show energising (pilot indicator and pump driving indicator), Pump stop function, Bump test function, IrDA Communication, Data logger, Password Protected

Warranty

2 year material and workmanship

 

Downloads

Downloads:

 

Specifications of the portable single gas monitors

 

Certification:

Videos

Videos:

GX-8000 Basic Training

Enquire Now

    Name*

    Phone*

    Name*

    Phone*

    Location

    Email*

    How did you hear about us?*

    What are you interested in?*

    Message