Single Gas Monitor – 04 Series

04 Series Single Gas Monitor
04 Series Single Gas Monitor toxic
04 Series Single Gas Monitor toxic

Features:

• 3 Year Warranty
• Personal monitoring for O2, H2S, CO
(Toxic – HCN, NO2, SO2, PH3, NH3 & CL2)
• CO with H2 elimination
• O2 / CO combo sensor
• Operates 3,000 hours on alkaline
• Pocket size 53mm (W) x 66mm (H) x 22mm (D)
• Lightweight approx 93 grams
• Impact, dust, and water resistant (IP-67)
• Replaceable rubber boot
• Data log 5 to 300 hours with adjustable intervals
• Audible / visual / vibration alarms
• Automatic backlight
• Low battery alarm
• Intrinsically safe, IECEx/ATEX

Application/s:

• Hazardous material
• Mining
• Refineries / petrochemical
• Water / wastewater treatment
• Pharmaceuticals
• Utilities
• Chemical plants
• Fire services

04 Series Single Gas Monitor Overview:

Single Gas Monitor (Toxic)

The 04 Series toxic single gas monitor is designed to operate for many years. The HCN, NO2, SO2, PH3 and NH3 versions can be operated continuously for at least 3,000 hours on (2) AAA size alkaline batteries. The 04 models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. 

 Single Gas Monitor (Standard) 

This single gas monitor is designed to operate for many years. These models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. 

Sensors have a life expectancy of over 3 years and backed by a 3 Year Warranty. 

Each 04 Series monitor is impact, dust, and water resistant with an IP-67 rating. 04 Series instruments are safe for use in hazardous locations, classified as intrinsically safe IECEx/ATEX. 

04 Series Single Gas Monitor Specifications:

 

Model Name

SC-04 HCN

SC-04 NO2

SC-04 PH3

SC-04 SO2

CO-04 (-H2)

CX-04

Gas Detected

Hydrogen Cyanide

Nitrogen Dioxide

Phosphine

Sulfur Dioxide

Carbon Monoxide

CO

O2

Detection Principle

Electrochemical

Part#

73-0071

73-0073

73-0079

73-0083

73-0067

73-0069

Detection Range (Increments)

0 ~ 30.0 ppm
(0.1 ppm)
0 ~ 20.00 ppm
(0.05 ppm)
0 ~ 20.00 ppm
(0.01 ppm)
0 ~ 100.0 ppm
(0.05 ppm)
0 ~ 2000 ppm
(1 ppm)
0 ~ 40%
(0.1%)

Alarm Set Points

1st: 5.0 ppm
2nd: 10.0 ppm
3rd: 30.0 ppm
TWA: 4.7 ppm
STEL: 10 ppm
1st: 2.00 ppm
2nd: b4.00 ppm
3rd: 20.00 ppm
TWA: 0.50 ppm
STEL: 1.00 ppm
1st: 0.30 ppm
2nd: 0.60 ppm
3rd: 0.60 ppm
TWA: 0.30 ppm
STEL: 1.00 ppm
1st: 2.00 ppm
2nd: 5.00 ppm
3rd: 100.00 ppm
TWA: 2.00 ppm
STEL 5.00 ppm
1st 25 ppm
2nd 50 ppm
3rd 1200 ppm
TWA 25 ppm
STEL 200 ppm
L: 19.5 %
LL: 18.0%
H: 25.0 %

Alarm Types

Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA
Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error

Alarm Methods

Gas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration
Trouble alarm: Flashing LED’s, intermittent buzzer, and display of error message
STEL & TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration

Gas Sampling

Diffusion

Response Time

T90 in 30 seconds

Accuracy

(which ever is greater)

± 10% of reading
or ± 5 % of full scale
< 300 ppm ± 5 % of reading
> 300 ppm ± 20 % of reading
< 25% ± 0.5 %
> 25% ± 3.0 %

Data Logging

10 second intervals = 10 hours, 5 minute intervals = 300 hours, 10 minute intervals = 600 hours
Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.

Battery Options

Alkaline dry cell (2-AAA size)

Continuous Operation

3,000 hours (at 25°C, no backlight) 6,200 hours 4,600 hours

Safety Rating

ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D

Enclosure

Dust and water resistant with IP-67 rating

Dimensions & Weight

2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g)

Display

Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon

Operating Temp. & Humidity

-4°F ~ 122°F (-20°C ~ 50°C);
Humidity below 90% RH (non-condensing)

Standard Accessories

• Rubber protective boot • Alligator clip • Data logging software
• Alkaline batteries

Optional Accessories

• Calibration cap • Wrist strap
• Calibration kit • Belt clip • Data logging download cable

Special Functions

• Manual backlight for LCD (automatically lit during alarm)
• Peak hold, STEL & TWA

Warranty

3 Year warranty

04 Series Single Gas Monitor Downloads:

Specifications:

04 Series Datasheet

04 Series Toxics Datasheet

04 Series Single Gas Monitor Accessories:

04 Series Single Gas Detector Alligator Clip

Alligator Clip

04 Series Calibration Cap

Calibration Cap

04 Series Single Gas Detector Belt Clip

Belt Clip

04 Series Arm Band

Arm Band

04 Series Single Gas Monitor Heat Resistant Case

Heat-Resistant Case

Wrist Strap

Wrist Strap

Overview

04 Series Single Gas Monitor Overview:

Single Gas Monitor (Toxic)

The 04 Series toxic single gas monitor is designed to operate for many years. The HCN, NO2, SO2, PH3 and NH3 versions can be operated continuously for at least 3,000 hours on (2) AAA size alkaline batteries. The 04 models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. 

 Single Gas Monitor (Standard) 

This single gas monitor is designed to operate for many years. These models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. 

Sensors have a life expectancy of over 3 years and backed by a 3 Year Warranty. 

Each 04 Series monitor is impact, dust, and water resistant with an IP-67 rating. 04 Series instruments are safe for use in hazardous locations, classified as intrinsically safe IECEx/ATEX. 

Specifications

04 Series Single Gas Monitor Specifications:

 

Model Name

SC-04 HCN

SC-04 NO2

SC-04 PH3

SC-04 SO2

CO-04 (-H2)

CX-04

Gas Detected

Hydrogen Cyanide

Nitrogen Dioxide

Phosphine

Sulfur Dioxide

Carbon Monoxide

CO

O2

Detection Principle

Electrochemical

Part#

73-0071

73-0073

73-0079

73-0083

73-0067

73-0069

Detection Range (Increments)

0 ~ 30.0 ppm
(0.1 ppm)
0 ~ 20.00 ppm
(0.05 ppm)
0 ~ 20.00 ppm
(0.01 ppm)
0 ~ 100.0 ppm
(0.05 ppm)
0 ~ 2000 ppm
(1 ppm)
0 ~ 40%
(0.1%)

Alarm Set Points

1st: 5.0 ppm
2nd: 10.0 ppm
3rd: 30.0 ppm
TWA: 4.7 ppm
STEL: 10 ppm
1st: 2.00 ppm
2nd: b4.00 ppm
3rd: 20.00 ppm
TWA: 0.50 ppm
STEL: 1.00 ppm
1st: 0.30 ppm
2nd: 0.60 ppm
3rd: 0.60 ppm
TWA: 0.30 ppm
STEL: 1.00 ppm
1st: 2.00 ppm
2nd: 5.00 ppm
3rd: 100.00 ppm
TWA: 2.00 ppm
STEL 5.00 ppm
1st 25 ppm
2nd 50 ppm
3rd 1200 ppm
TWA 25 ppm
STEL 200 ppm
L: 19.5 %
LL: 18.0%
H: 25.0 %

Alarm Types

Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA
Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error

Alarm Methods

Gas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration
Trouble alarm: Flashing LED’s, intermittent buzzer, and display of error message
STEL & TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration

Gas Sampling

Diffusion

Response Time

T90 in 30 seconds

Accuracy

(which ever is greater)

± 10% of reading
or ± 5 % of full scale
< 300 ppm ± 5 % of reading
> 300 ppm ± 20 % of reading
< 25% ± 0.5 %
> 25% ± 3.0 %

Data Logging

10 second intervals = 10 hours, 5 minute intervals = 300 hours, 10 minute intervals = 600 hours
Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.

Battery Options

Alkaline dry cell (2-AAA size)

Continuous Operation

3,000 hours (at 25°C, no backlight) 6,200 hours 4,600 hours

Safety Rating

ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D

Enclosure

Dust and water resistant with IP-67 rating

Dimensions & Weight

2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g)

Display

Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon

Operating Temp. & Humidity

-4°F ~ 122°F (-20°C ~ 50°C);
Humidity below 90% RH (non-condensing)

Standard Accessories

• Rubber protective boot • Alligator clip • Data logging software
• Alkaline batteries

Optional Accessories

• Calibration cap • Wrist strap
• Calibration kit • Belt clip • Data logging download cable

Special Functions

• Manual backlight for LCD (automatically lit during alarm)
• Peak hold, STEL & TWA

Warranty

3 Year warranty
Downloads

04 Series Single Gas Monitor Downloads:

Specifications:

04 Series Datasheet

04 Series Toxics Datasheet

Accessories

04 Series Single Gas Monitor Accessories:

04 Series Single Gas Detector Alligator Clip

Alligator Clip

04 Series Calibration Cap

Calibration Cap

04 Series Single Gas Detector Belt Clip

Belt Clip

04 Series Arm Band

Arm Band

04 Series Single Gas Monitor Heat Resistant Case

Heat-Resistant Case

Wrist Strap

Wrist Strap

Video

Enquire Now:

    Name*

    Phone*

    Location*

    If Other

    Email*

    How did you hear about us?*

    What are you interested in?*